Warning | : Do | not | replace | a nondefective FRU. |
| Reseat | the | keyboard | cables. |
| Replace | the | DC/DC card. | |
| Replace | the | system board. |
Auxiliary | Input | Devices: | The following auxiliary | |
input devices | are supported: | |||
Numeric keypad |
| |||
Mouse | (PS/2 | compatible) | ||
External | keyboard | (with keyboard/mouse cable) |
If any of these devices do not work, reseat the cable connector and repeat the failing operation.
If the problem remains, replace the device, and then the system board.
Memory Checkout
DIMMs are available for increasing memory capacity.
DIMM |
|
|
| Displayed | Value |
|
| ||
|
|
|
|
|
|
| |||
No | DIMM installed |
| 32192 | KB |
|
| |||
|
|
|
|
|
|
|
|
| |
16 | MB |
|
| 48576 | KB |
|
|
| |
|
|
|
|
|
|
|
|
| |
32 | MB |
|
| 64960 | KB |
|
|
| |
|
|
|
|
|
|
|
|
| |
64 | MB |
|
| 97728 | KB |
|
|
| |
|
|
|
|
|
|
| |||
Memory errors | may | cause | error messages | to appear on | |||||
the | screen or | may | hang | the | operating | system. |
Take the following procedure to isolate memory problems:
1.Turn off the computer and remove any installed DIMM from the slot.
2.Press and holdF1 theky; then turn on the
| computer. Hold | theF1 key down until the |
|
|
| ||||||||||
|
|
|
|
|
|
|
|
| |||||||
3. | SelectTest | and | pressEnter . |
|
|
|
|
|
|
|
| ||||
4. | SelectMemory |
|
| and | pressEnter | to | run | the | memory |
| |||||
| test for the base memory. If an error appears, | ||||||||||||||
| replace | the | system board. |
|
|
|
|
|
| ||||||
5. | Turn off | the | computer | and | reinstall | the | DIMM; | then | |||||||
| turn on the computer. Verify | the | memory | size; | then | ||||||||||
| test the memory. If an error message appears, | ||||||||||||||
| replace | the | DIMM. |
|
|
|
|
|
|
|
| ||||
If a memory problem occur | intermittently, | perform | the loop | ||||||||||||
option | test. If | the | test | detects | an | error, it | prints an error | ||||||||
log on a printer connected to the parallel port. See | |||||||||||||||
“Displaying | the | Error | Log” | on | page 35 | for | more |
| |||||||
information. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Flash | Memory | Update: |
| System setup programs and |
|
| |||||||||
diagnostic | tests | are stored in the flash memory. A flash | |||||||||||||
memory | update | is | required | when: |
|
|
|
|
|
| |||||
| A | new | version | of | the system | program | is | installed. |
12