Cisco Systems MDS 9100 Series manual Installing the Switch on the Shelf Brackets, Statement

Page 80

Appendix A Cabinet and Rack Installation

Cisco MDS 9000 Family Telco and EIA Shelf Bracket

Step 4 Attach the crossbar to the shelf brackets as shown in Figure A-2, using the 10-32 screws.

Step 5 Insert the slider rails into the shelf brackets as shown in Figure A-2. Then attach them to the rear rack-mounting rails using a minimum of four 12-24 or 10-24 screws.

Installing the Switch on the Shelf Brackets

This section provides general instructions for installing the switch on top of the shelf brackets. For detailed installation instructions, see the “Installing the Switch in a Cabinet or Rack” section on page 2-5.

Warning This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.

Statement 1017

Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.

Statement 1030

Note Before you install, operate, or service the system, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family for important safety information.

To install the switch on top of the shelf brackets, follow these steps:

Step 1 Verify that the shelf brackets are level and securely attached to the rack-mounting rails, the crossbar is securely attached to the shelf brackets, and the rack is stabilized.

Step 2 Slide the switch onto the shelf brackets, ensuring that it is squarely positioned.

Step 3 Attach the switch to the rack-mounting rails. See the “Installing the Switch in a Cabinet or Rack” section on page 2-5.

Caution We recommend grounding the chassis, even if the rack is already grounded. A grounding pad with two threaded M4 holes is provided on the chassis for attaching a grounding lug.

Note The grounding lug must be NRTL listed and compatible with copper conductors. Only copper conductors (wires) must be used and the copper conductor must comply with National Electrical Code (NEC) for ampacity.

Cisco MDS 9100 Series Hardware Installation Guide

 

A-8

OL-16187-01

 

 

 

Image 80
Contents Cisco MDS 9100 Series Hardware Installation Guide Americas HeadquartersCisco MDS 9100 Series Hardware Installation Guide N T E N T S Preinstallation Cabinet and Rack Requirements A-1 Cables and Adapters C-1 Console Port C-2 Changed Feature Description Release Where Documented Switch Installing the Cisco MDSSwitch Port Cisco MDS 9124 Switch Specific Cisco MDS Description of the Cisco MDS 31aInstallation Clearance Jumper power Jumper power cord available for Not releaseShelf Bracket Allows single-user installation Specific Kit Installation in a Telco rackChapter Title Description AudienceOrganization Document Conventions Chapter Title DescriptionPreface Regulatory Compliance and Safety Information Hardware InstallationRelated Documentation Release NotesCommand-Line Interface Troubleshooting and ReferenceInstallation and Configuration Note Cisco MDS 9000 Family SSM Configuration NoteXiv Product Overview Cisco MDS 9100 Series Multilayer Fabric Switches Cisco MDS 9134 Switch Cisco MDS 9134 SwitchCisco MDS 9124 Switch Cisco MDS 9140 SwitchCisco MDS Fibre Channel Bladeswitch for IBM BladeCenter Cisco MDS 9120 SwitchPower Supplies Fan ModulesPorts Port Group Ports on the Cisco MDS 9134 SwitchCisco MDS 9100 Series Ports 6shows the Cisco MDS 9134 ports Ports on the Cisco MDS 9124 Switch Cisco MDS 9124 PortsSwitch LEDs Fan module status LED10 Cisco MDS 9124 Switch LEDs LED Status DescriptionSupported SFP Transceivers Fibre Channel SFP TransceiversCombination Fibre Channel/Gigabit Ethernet SFP Transceivers Installing the Cisco MDS 9100 Series This section includes the following information PreinstallationInstallation Options Installation Guidelines Unpacking and Inspecting the Switch Required EquipmentInstalling the Switch in a Cabinet or Rack To 36-inch slider rails To 30-inch slider railsQuantity Per kitFront-Facing Installation Description Quantity96616 Installing the Slider Rails Sliding the Cisco MDS 9100 Series onto the Slider Rails 182460 Attaching the Switch to the Rack Cisco MDS 9100 Series Hardware Installation Guide Front rack-mount bracket Bracket Series Front cabinet Mounting rails Rear cabinet mounting Rails Front cabinet Mounting Rails Rear cabinet 113430 182462 Rear cabinet Mounting Rails Front cabinet 182466 182464 270195 Grounding the Switch LugStarting Up the Switch Installing the Cisco MDS 9100 Series Starting Up the Switch Removing and Installing Components Power module Fan Module Power modules Fan modules Installing Power Supplies Removing and Installing Power SuppliesRemoving Power Supplies Removing and Installing Fan Modules Locate the fan module in the back of the switchTo remove the existing fan module, follow these steps Slide the seating tabs toward the center of the fan moduleOL-16187-01 Installing a Fan Module 25shows the Cisco MDS 9134 fan moduleVerifying the Fan Module OL-16187-01 Connecting the Console Port Preparing for Network ConnectionsConnecting the Console Port to a PC Connecting the Console CableConnecting the 10/100 Ethernet Management Port Connecting a Modem to a Console PortConnecting to a Fibre Channel Port Removing and Installing SFP TransceiversInstalling an SFP Transceiver SFP Transceiver with Mylar Tab LatchRemoving an SFP Transceiver Removing and Installing Cables into SFP Transceivers Installing a Cable into an SFP TransceiverConnecting the LC-Type Cable to a Fibre Channel Port Removing a Cable from an SFP TransceiverMaintaining SFP Transceivers and Fiber-Optic Cables OL-16187-01 This appendix includes the following information Cabinet and Rack RequirementsGeneral Requirements for Cabinets and Racks Requirements Specific to Perforated Cabinets Reference Perforated CabinetCisco MDS 9000 Family Telco and EIA Shelf Bracket Requirements Specific to Solid-Walled CabinetsRequirements Specific to Standard Open Racks Requirements Specific to Telco RacksRack-Mounting Guidelines Rack Type MDS EIA 4-post45 lb 30 lb 15 lb Telco 2 postBefore Installing the Shelf Brackets Installing the Shelf Bracket Kit into a Two-Post Telco RackRequired Equipment Quantity Part DescriptionCisco MDS 9100 Series Hardware Installation Guide Installing the Shelf Bracket Kit into a Four-Post EIA Rack Figure A-2 Installing the Shelf Bracket Kit into an EIA RackInstalling the Switch on the Shelf Brackets StatementRemoving the Shelf Bracket Kit Optional OL-16187-01 Switch Specifications Description SpecificationPower Specifications General Power Supply Specifications AC-Input Power Supply SpecificationPower watts BTU/hr Amps AC-Input Heat Diss 85 VAC 110 VAC 220 VACSFP Transceiver Specifications Connection Guidelines for AC-Powered SystemsCisco Fibre Channel SFP Transceivers Part Number Description TypeConnector type Wavelength 850 nm 1310 nm Fiber type Description Short wavelength Long wavelengthGeneral Specifications for Cisco GE/FC SFP Transceivers Parameter Symbol Min Max UnitCisco Gigabit Ethernet/Fibre Channel Transceivers Gbps Ethernet SFPCisco Cwdm SFP Transceivers Part Number DescriptionAdd/drop multiplexer for four Cwdm wavelengths Add/drop multiplexer for eight Cwdm wavelengthsGeneral Specifications for Cisco Cwdm SFP Transceivers Description ColorParameter Symbol Min Typical Max Units Optical Specifications for Cisco Cwdm SFP TransceiversParameter Symbol Minimum Typical Maximum Units X2 Transceiver Specifications Product Number DescriptionModal Core Size Bandwidth Maximum Cabling X2 Product Number Cable Type Microns MHz/km DistanceModal Bandwidth Maximum Cabling X2 Product NumberTransmit and Receive X2 Product Number Wavelength nmOL-16187-01 Cable and Port Specifications Cables and AdaptersConsole Port Pinouts Pin SignalConsole Port Signal RJ-45 Pins DB-9 Pin Mgmt 10/100 Ethernet PortRJ-45 to DB-25 Console RJ-45 to DB-9 ConsoleNot used Supported Power Cords and PlugsPower Cords Jumper Power Cord Figure C-3 300-W Power Supply PlugsC15 C14 Site Planning and Maintenance Records Site Preparation ChecklistTask No Planning Activity Verified By Time Date Contact and Site Information Chassis and Network Information D E IN-2 IN-3 IN-4