Appendix B Technical Specifications
Power Specifications
General Power Supply Specifications
Table
Table
| Specification |
|
|
Minimum = 85 VAC | |
| Nominal = 100 to 240 VAC |
| Maximum = 264 VAC |
|
|
4.7 A at 85 VAC | |
(maximum) | 3.6 A at 110 VAC |
| 1.8 A at 220 VAC |
| Note For plug current rating, see the |
| “Jumper Power Cord” section on |
| page |
|
|
Minimum = 47 Hz | |
| Nominal = 50 to 60 Hz |
| Maximum = 63 Hz |
|
|
Power supply output capacity | 300 W |
|
|
Power supply output voltage | 12 V +/- 6% up to 25 A |
|
|
Output holdup time | 20 ms when input > 100 VAC |
|
|
Power Supply Requirements and Heat Dissipation Specifications
Table
Table | Power and Heat Dissipation |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| Input Current |
|
|
|
|
|
|
|
|
|
|
| Heat Diss. | 85 VAC | 110 VAC | 220 VAC |
Model Number/ |
| Power (watts) | (BTU/hr) | (amps) | (amps) | (amps) |
|
|
|
|
|
| |
Cisco MDS 9134 Switch | 96 maximum | 330 | 1.41 | 1.10 | .55 | |
(with fan modules) |
|
|
|
|
| |
|
|
|
|
|
| |
Cisco MDS 9124 Switch | 96 maximum | 330 | 1.41 | 1.10 | .55 | |
(with fan modules) |
|
|
|
|
| |
|
|
|
|
|
| |
Cisco MDS 9140 Switch | 204 maximum | 870 | 3.0 | 2.32 | 1.16 | |
(with fan modules) |
|
|
|
|
| |
|
|
|
|
|
| |
Cisco MDS 9120 Switch | 180 maximum | 752 | 2.65 | 2.05 | 1.02 | |
(with fan modules) |
|
|
|
|
| |
|
|
|
|
|
|
|
Tip To prevent a loss of input power, ensure the total maximum load on each circuit supplying the power supply is within the current ratings of the wiring and breakers.
Cisco MDS 9100 Series Hardware Installation Guide
|
| |
|