Cisco Systems MDS 9100 Series manual Cisco Cwdm SFP Transceivers, Part Number Description

Page 89

Appendix B Technical Specifications

SFP Transceiver Specifications

Table B-11 General Specifications for Cisco Gigabit Ethernet/Fibre Channel SFP Transceivers

Description

Short wavelength

Long wavelength

 

 

 

 

Connector type

LC

 

LC

 

 

 

 

Wavelength

850 nm

 

1310 nm

 

 

 

 

Fiber type

MMF

 

SMF

 

 

 

 

Core size

50 microns

62.5 microns

9/125 microns

 

 

 

 

Cable distance1

300 m

150 m

10 km

Transmit power

-1.5 to -9.5 dBm

-3 to -9.5 dBm

 

 

 

 

1. Approximate; actual distance may vary depending on fiber quality and other factors.

Environmental and Electrical Specifications for Cisco GE/FC SFP Transceivers

Table B-12provides the maximum environmental and electrical ratings for Cisco GE/FC SFP transceivers.

Table B-12 Maximum Environmental and Electrical Ratings for Cisco GE/FC SFP Transceivers

Parameter

Symbol

Min.

Max.

Unit

 

 

 

 

 

 

 

 

Storage temperature1

T

S

 

-40

100

°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Case temperature1, 2

T

C

 

0

85

°C

 

 

 

 

 

 

 

 

 

 

 

 

Relative humidity1

RH

 

5

95

%

Module supply voltage1

V

CC

T,R

3.1

3.5

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Absolute maximum ratings are those values beyond which damage to the device may occur if these limits are exceeded for other than a short period of time. See Reliability Data Sheet for specific reliability performance.

2.Functional performance is not intended, device reliability is not implied, and damage to the device may occur over an extended period of time between absolute maximum ratings and the recommended operating conditions.

Cisco CWDM SFP Transceivers

Table B-13lists the CWDM SFP transceivers available through Cisco Systems. These SFP transceivers are supported by the Cisco MDS 9140 and Cisco MDS 9120 switch.

Table B-13 Cisco CWDM SFP Transceivers

Part Number

Description

 

 

DS-CWDM-xxxx

Gigabit Ethernet and 1-Gbps/2-Gbps/4-Gbps Fibre Channel SFP LC interface

 

xxxx where xxxx = 1470, 1490, 1510, 1530, 1550, 1570, 1590, or 1610 nm.

 

 

DS-CWDM-MUX-4

Add/drop multiplexer for four CWDM wavelengths.

 

 

DS-CWDM-MUX-8

Add/drop multiplexer for eight CWDM wavelengths.

 

 

DS-CWDMCHASSIS

Two slot chassis for CWDM add/drop multiplexers.

 

 

Cisco MDS 9100 Series Hardware Installation Guide

 

OL-16187-01

B-7

 

Image 89
Contents Americas Headquarters Cisco MDS 9100 Series Hardware Installation GuideCisco MDS 9100 Series Hardware Installation Guide N T E N T S Preinstallation Cabinet and Rack Requirements A-1 Cables and Adapters C-1 Console Port C-2 Switch Installing the Cisco MDS Changed Feature Description Release Where DocumentedSwitch Port Cisco MDS 9124 Switch Specific Cisco MDS Description of the Cisco MDS 31aJumper power Jumper power cord available for Not release Installation ClearanceShelf Bracket Allows single-user installation Specific Kit Installation in a Telco rackChapter Title Description AudienceOrganization Chapter Title Description Document ConventionsPreface Hardware Installation Regulatory Compliance and Safety InformationRelated Documentation Release NotesTroubleshooting and Reference Command-Line InterfaceInstallation and Configuration Note Cisco MDS 9000 Family SSM Configuration NoteXiv Product Overview Cisco MDS 9100 Series Multilayer Fabric Switches Cisco MDS 9134 Switch Cisco MDS 9134 SwitchCisco MDS 9140 Switch Cisco MDS 9124 SwitchCisco MDS 9120 Switch Cisco MDS Fibre Channel Bladeswitch for IBM BladeCenterFan Modules Power SuppliesPorts Port Group Ports on the Cisco MDS 9134 SwitchCisco MDS 9100 Series Ports 6shows the Cisco MDS 9134 ports Cisco MDS 9124 Ports Ports on the Cisco MDS 9124 SwitchFan module status LED Switch LEDs10 Cisco MDS 9124 Switch LEDs Status Description LEDFibre Channel SFP Transceivers Supported SFP TransceiversCombination Fibre Channel/Gigabit Ethernet SFP Transceivers Installing the Cisco MDS 9100 Series This section includes the following information PreinstallationInstallation Options Installation Guidelines Required Equipment Unpacking and Inspecting the SwitchTo 36-inch slider rails To 30-inch slider rails Installing the Switch in a Cabinet or RackQuantity Per kitDescription Quantity Front-Facing Installation96616 Installing the Slider Rails Sliding the Cisco MDS 9100 Series onto the Slider Rails 182460 Attaching the Switch to the Rack Cisco MDS 9100 Series Hardware Installation Guide Front rack-mount bracket Bracket Series Front cabinet Mounting rails Rear cabinet mounting Rails Front cabinet Mounting Rails Rear cabinet 113430 182462 Rear cabinet Mounting Rails Front cabinet 182466 182464 270195 Lug Grounding the SwitchStarting Up the Switch Installing the Cisco MDS 9100 Series Starting Up the Switch Removing and Installing Components Power module Fan Module Power modules Fan modules Installing Power Supplies Removing and Installing Power SuppliesRemoving Power Supplies Locate the fan module in the back of the switch Removing and Installing Fan ModulesTo remove the existing fan module, follow these steps Slide the seating tabs toward the center of the fan moduleOL-16187-01 25shows the Cisco MDS 9134 fan module Installing a Fan ModuleVerifying the Fan Module OL-16187-01 Preparing for Network Connections Connecting the Console PortConnecting the Console Cable Connecting the Console Port to a PCConnecting a Modem to a Console Port Connecting the 10/100 Ethernet Management PortRemoving and Installing SFP Transceivers Connecting to a Fibre Channel PortSFP Transceiver with Mylar Tab Latch Installing an SFP TransceiverRemoving an SFP Transceiver Installing a Cable into an SFP Transceiver Removing and Installing Cables into SFP TransceiversRemoving a Cable from an SFP Transceiver Connecting the LC-Type Cable to a Fibre Channel PortMaintaining SFP Transceivers and Fiber-Optic Cables OL-16187-01 This appendix includes the following information Cabinet and Rack RequirementsGeneral Requirements for Cabinets and Racks Reference Perforated Cabinet Requirements Specific to Perforated CabinetsRequirements Specific to Solid-Walled Cabinets Cisco MDS 9000 Family Telco and EIA Shelf BracketRequirements Specific to Standard Open Racks Requirements Specific to Telco RacksRack Type MDS EIA 4-post Rack-Mounting Guidelines45 lb 30 lb 15 lb Telco 2 postInstalling the Shelf Bracket Kit into a Two-Post Telco Rack Before Installing the Shelf BracketsRequired Equipment Quantity Part DescriptionCisco MDS 9100 Series Hardware Installation Guide Figure A-2 Installing the Shelf Bracket Kit into an EIA Rack Installing the Shelf Bracket Kit into a Four-Post EIA RackStatement Installing the Switch on the Shelf BracketsRemoving the Shelf Bracket Kit Optional OL-16187-01 Description Specification Switch SpecificationsPower Specifications AC-Input Power Supply Specification General Power Supply SpecificationsPower watts BTU/hr Amps AC-Input Heat Diss 85 VAC 110 VAC 220 VACConnection Guidelines for AC-Powered Systems SFP Transceiver SpecificationsCisco Fibre Channel SFP Transceivers Part Number Description TypeDescription Short wavelength Long wavelength Connector type Wavelength 850 nm 1310 nm Fiber typeParameter Symbol Min Max Unit General Specifications for Cisco GE/FC SFP TransceiversCisco Gigabit Ethernet/Fibre Channel Transceivers Gbps Ethernet SFPPart Number Description Cisco Cwdm SFP TransceiversAdd/drop multiplexer for four Cwdm wavelengths Add/drop multiplexer for eight Cwdm wavelengthsDescription Color General Specifications for Cisco Cwdm SFP TransceiversParameter Symbol Min Typical Max Units Optical Specifications for Cisco Cwdm SFP TransceiversParameter Symbol Minimum Typical Maximum Units Product Number Description X2 Transceiver SpecificationsModal Core Size Bandwidth Maximum Cabling X2 Product Number Cable Type Microns MHz/km DistanceBandwidth Maximum Cabling X2 Product Number ModalTransmit and Receive X2 Product Number Wavelength nmOL-16187-01 Cables and Adapters Cable and Port SpecificationsConsole Port Pinouts Pin SignalConsole Port Mgmt 10/100 Ethernet Port Signal RJ-45 Pins DB-9 PinRJ-45 to DB-25 Console RJ-45 to DB-9 ConsoleNot used Supported Power Cords and PlugsPower Cords Figure C-3 300-W Power Supply Plugs Jumper Power CordC15 C14 Site Preparation Checklist Site Planning and Maintenance RecordsTask No Planning Activity Verified By Time Date Contact and Site Information Chassis and Network Information D E IN-2 IN-3 IN-4