Cisco Systems ME 4924-10GE manual Powering On the Switch and Running Post

Page 35

Chapter 2 Switch Installation

Preparing for Installation

None (flow control)

Step 2 Use the supplied RJ-45-to-DB-9 adapter cable to insert the RJ-45 connector into the console port, as shown in Figure 2-1.

Figure 2-1 Connecting to the Console Port

1

13

14

15

16

17

18

 

 

 

 

 

 

 

 

 

 

19

20

21

22

 

 

 

 

 

 

 

 

 

 

23

24

Cisco ME 4924-10GE

1

3

2

154861

Cisco ME

2

PC

3

Console cable

4924-10GE

 

 

 

 

 

 

 

 

 

Step 3 Attach the DB-9 female DTE adapter of the RJ-45-to-DB-9 adapter cable to a PC, or attach an appropriate adapter to the terminal.

Step 4 Start the terminal-emulation program if you are using a PC or terminal.

Powering On the Switch and Running POST

To power on the switch, follow these steps:

Step 1 Make sure that you have started the terminal emulation software program (such as ProComm, HyperTerminal, tip, or minicom) from your management station. See the “Connecting a PC or Terminal to the Console Port” section on page 2-4for information on connecting to the switch console port.

Step 2 If you are using an AC power supply, connect one end of the AC power cord to the AC power connector on the switch, and then connect the other end of the power cord to an AC power outlet.

Step 3 If you are using a DC power supply, see the “Connecting DC Power to the Cisco ME 4924-10GE Switch” section on page 3-3for instructions on how to connect the DC power supply.

Step 4 Secure the power cord with the power cord retainer. For more information, see the “Connecting AC Power to the Cisco ME 4924-10GE Switch” section on page 3-2.

Cisco ME 4924-10GE Ethernet Switch Hardware Installation Guide

 

OL-10071-01

2-5

 

 

 

Image 35
Contents Text Part Number OL-10071-01 Corporate HeadquartersPage Iii N T E N T SPower Management for the Cisco ME 4924-10GE Switch Understanding Post Results OL-10071-01 Organization PrefaceAudience PurposeViii ConventionsStatement 1071-Warning Definition Säilytä Nämä Ohjeet Guarde Estas Instruções GEM Disse Anvisninger Xii Xiii Xiv Related PublicationsObtaining Documentation Cisco.comProduct Documentation DVD Ordering Documentation Documentation FeedbackCisco Product Security Overview Xvi Reporting Security Problems in Cisco ProductsProduct Alerts and Field Notices Xvii Obtaining Technical AssistanceCisco Technical Support & Documentation Website Xviii Submitting a Service RequestDefinitions of Service Request Severity Obtaining Additional Publications and InformationXix OL-10071-01 Product Overview FeaturesHardware Features Software Features Optical Support Front Panel DescriptionConsole Port LEDs Management PortSFP Module Ports FAN LED Status LED Color or State Description LEDRear Panel Description Power SuppliesManagement Options Environmental Monitoring of the Power SuppliesPower Management for the Cisco ME 4924-10GE Switch Power Management ModesNetwork Configurations OL-10071-01 Preparing for Installation Switch InstallationStatement Installation Guidelines Verifying Package Contents Connecting a PC or Terminal to the Console Port Verifying Switch OperationConnecting to the Console Port Powering On the Switch and Running PostAttaching Brackets to the Switch Rack-Mounting the SwitchPowering Off the Switch and Disconnecting the Console Port Attaching the Cable Guide Installing and Removing SFP ModulesMounting the Switch in a Rack 4shows an SFP module that has a bale-clasp latch Installing SFP Modules into SFP Module PortsRemoving SFP Modules from SFP Module Ports Installing an SFP Module into an SFP Module PortConnecting to a Fiber-Optic SFP Module Connecting to an SFP ModuleConnecting to a Fiber-Optic SFP Module Port X2 Module Handling Guidelines and Installation Connecting to 1000BASE-T SFP Modules10-Gigabit Ethernet X2 Module Specification Description10 Installing the 10-Gigabit Ethernet X2 Module Installing the 10-Gigabit Ethernet X2 ModuleOL-10071-01 Removing the 10-Gigabit Ethernet X2 Module Module Maintenance GuidelinesCleaning the Fiber-Optic Connectors Where to Go Next Grounding Requirements Connecting the Power SupplyConnecting AC Power to the Cisco ME 4924-10GE Switch Connecting DC Power to the Cisco ME 4924-10GE Switch DC Power Supply Understanding Post Results TroubleshootingSymptom Possible Cause Resolution Diagnosing ProblemsGbic-invalid global Troubleshooting the Hardware ComponentsGetting Started Problem Solving to the System Component LevelIdentifying Startup Problems LED and Color Meaning LED ReadingsTroubleshooting the Power Supply Contacting Customer ServiceAC Power Technical SpecificationsSafety DC PowerConnecting to 1000BASE-T Devices Connector and Cable SpecificationsConnector Specifications Figure B-2 Identifying a Crossover CableAdapter Pinouts Cable and Adapter SpecificationsSwitch Console RJ-45-to-DB-9 Port DTE Switch Console RJ-45-to-DB-25 Port DTEConsole Port Pin Signal Direction DescriptionConnecting to the Switch Initial Configuration for the SwitchStarting the Terminal-Emulation Software Figure C-1 Connecting a Switch to a PCConnecting to a Power Source Performing the Initial Configuration Entering the Initial Configuration InformationIP Settings Configure an enable password, and press Return Save the running configuration IN-1 NumericsIN-2 IN-3 PostIN-4 Startup