User frames | Standard processing in SVP mode |
SPECIFY SWAP NO. | <=> |
Enter two file numbers which are to be swapped. You can only make entries if you select function 1 beforehand.
Special key functions
P8
P7
Sets 4 to 7 are displayed
Sets 0 to 3 are displayed
6.4.8.3(AU3) AUXILIARY FRAME: RELATED SCB’S
i
This frame is intended exclusively for use by the service department.
E02L01F |
NUMBER OF RELATED SCB'S | => 04 K |
NUMBER OF
|
| *PF6 CANCEL |
|
| *PF12 CATALOG |
RUN | ||
|
| M |
|
| FLAG CODE = F6C0C100 00000F00 |
LTG |
| TAST |
Figure 29: AUXILIARY FRAME: RELATED SCB’S screen
An entry in this frame sets the memory size for related SCBs (related Subchannel Control Block). Values from 01 to 16 are possible.
Special key functions
P6
P12
erase input
save input in SVP