Concept of system operation

3.2 Concept of system operation

V7

System operation is described in the chapter “Basics of system operation“ of the “SINIX-2000 V7.0“ [1] manual.

The following section lists the most important hardware and software components for S130 operation.

3.2.1 Hardware

Secondary

Console

 

 

console

 

 

 

serial

SKP

 

S130

 

 

 

 

I/O channel

CPU

serial

 

 

 

 

 

Radio-controlled clock/

 

LAN

 

GTS

 

 

serial

 

 

SVP

ATOP

 

V.24

 

 

 

 

 

On/off facility

 

 

 

LAN

 

The following hardware and software components are important for the operation of S130:

Service processor (SVP) in the S130 CPU.

This is responsible for the following tasks in the S130 CPU:

initialization

monitoring

controlling

hardware diagnosis

U25339-J-Z126-1-7600

7

Image 7
Contents Objectives and target group IntroductionNotational conventions Summary of contentsEmergency Stop Safety instructionsS130 Business Server Global storage Battery unit Important instructions RFI suppression Manufacturer instructions Manufacturer instructions Important instructions Configuration levels of the S130 Business Server OverviewModel Number of processors Performance factor Configuration levels of the S130 Business Server OverviewS130-C Processing units S130-E S130-K S130-P S130-T CPU Concept of system operationHardware Concept of system operationConcept of system operation Overview Software Authorization control Controls and indicators Status Function of the indicatorsControl panel on the Business Server cabinet 9999Meanings Controls and indicatorsControl panel on the Business Server cabinet Line Displays in line Ffffffffffffffff Displays in lineSystem Power CompleteCheck Button functions Control panel on the global storage cabinet Control panel on the global storage cabinetLine Displays in line CHK Cnct FfffffffffffffffThese indicators indicate the state of the backup battery Battery StatusSSU Check Emergency Stop Emergency Stop switchEmergency Stop switch Use the Emergency Stop switch as followsPage SKP Switching the S130 Business Server on and offSwitching the S130 on and off using the control panel Switching onAuxiliary Frame Load PRESET1 Switching the S130 on and off using the control panelSwitching off Switching the S130 on and off from the SKP Switching the S130 on and off from the SKPSwitching the S130 on and off from the SKP Switching the S130 on and off from the SKP Switching the S130 on and off from the SKP Switching the S130 on and off from the SKP Automatic switching on/off of the S130 via the SKP Automatic switching on/off of the S130 via the SKPAutomatic switching on/off of the S130 via the SKP Time-driven switching on and off of the SKP and S130 Time-driven switching on and off of the SKP and S130Switching the SKP and S130 on and off using Atop Switching the SKP and S130 on and off using AtopDCU Switching the S130 on and off from a remote systemSwitching global storage on and off Switching the S130 on and off from a remote systemStandard processing in SVP mode Invoking an SVP frame Invoking an SVP frame Standard processing in SVP modeInvoking an SVP frame SVPST0 #1 window password entry Password entry window is displayedGeneral frame structure Standard processing in SVP modeGeneral frame structure HOST/GUEST System status messages in lineCL-STOP Meaning of the status messages in line General frame structure Standard processing in SVP modeStatus displays in line Hardware status display in lineDisplays of the emulated terminal 9750 and their meaning P11 P12 P13 P14 P15 P16 P17 P18 P19 P20 F1 F2 F3 P10 Using framesUsing frames Standard processing in SVP mode SVP function keysOverview of the SVP function keys Using framesLock message Explanation of figure Frames are represented by this symbol Switching between user framesUser frames and subframes User frames Standard processing in SVP modeML Mode Selection Frame Selection of a particular CPU STOP/START Mode =User frames Load Function = LD Program Load Frame BasicLoad Clear Preset GroupAuxiliary Frame Load PRESET-1 LD Program Load Frame DETAIL-1MT Control = IPL from tape Parms =DETAIL-2 Status Cancel the procedureIs not heeded, BS2000 will be shut down abruptly IPL Execution = VM Mode =EXA Mode = LD Program Load Frame DETAIL-2ST Status Display Frame Cluster P8 Switches to the SSU Frame see nextStatus Display Frame SSU screen P7 Switches to the Cluster Frame see previousFirmware Dump MA Manual Operation FrameRate Control Adrs Compare StopAdrs SET = Rate Control =Adrs Type = Unit Adrs =AD ALTER/DISPLAY Frame Adrs Comp Mode =Function = Adrs = Facility =ABS KEYPRX PSWFCR FPRMessage Frame screen ME Message Frame00 ... FF CH CH/SUBCH Status Display Frame ChannelCHP no = Chpid =P10 P11 AU Auxiliary Frame Menu Delete input Corrections are carried out by the SVP 8.1 AU1 Auxiliary Frame Real ClockProtect Next Power on Reset NO. =8.2 AU2 Auxiliary Frame Iorsf Control SET noErase input Save input in SVP Specify Swap noSets 4 to 7 are displayed Sets 0 to 3 are displayed 8.3 AU3 Auxiliary Frame Related SCB’S8.4 AU4 Auxiliary Frame P-OFF/IMPL Power OFFImpl Preset Group 8.5 AU5 Auxiliary Frame Load PRESET1Power on IPL = Load Frame Basic Initial Frame =Load Frame Detail Start IPL no = 8.6 AU7 Auxiliary Frame SSU-CLUSTER ConfigurationCurrent CFR File NO. = Init CFR File NO. =MSF Frame screen MF MSF FrameFrame line PA frame is not intended for use PA Performance AnalyzerSelecting Iorsf Examples of standard processing in SVP modeEnter the FR AU command in line 24 and press Enter Selecting IorsfEnter 2 in the SELECTION= field. Press Auxiliary Frame Menu screen is displayedAuxiliary Frame Iorsf Control screen is displayed On Reset NO.= field and press EnterActivating Iorsf Activating Iorsf Standard processing in SVP modeSet Iorsf must be activated with a Impl Program Load Frame PRESET1 Setting up Program Load Frame PRESET1IPL Device Preset Group Start Mode =Program Load Frame PRESET2 Setting up Program Load Frame PRESET2Executing IPL in Program Load Frame DETAIL-1 You must be in the Auxiliary Frame Load PRESET2 screenMT Control = Load Function = IPL Device = Unit Address =Frame You must be in the Program Load Frame DETAIL-1 screen Setting operating mode via Program Load Frame DETAIL-2Press the P9 key Program Load Frame DETAIL-2 screen appears Setting operating modeStandard processing in SVP mode Selecting the console window Operating the BS2000 consoleSystem operation Page Problems with the S130 TroubleshootingProblems with the S130 Troubleshooting Displays in the case of a hardware errorProblems with the S130 TroubleshootingCarrying out a system dump S130 without the high availability module Measures to take in the case of processing unit failureS130 with the high availability module Following frame is displayed Installation Y/NAre YOU Sure ? Enter Y or N N Problems with the service/console processor SKP Problems with the service/console processor SKPImportant key combinations Important key combinationsTroubleshootingUser Guide Related publicationsPlease apply to your local office for ordering the manuals SKP / 3970-KAx Operating ManualIntroductory Guide to Systems Support User Guide Sinix Data SheetData Communication Unit BS2000/OSD-BCCH/SUBCH Status Display Frame Channel IndexALTER/DISPLAY Frame AD AtopIorsf IndexProgram Load Frame Basic LD DETAIL-1 DETAIL-2 Mode Selection Frame Mode Selection Frame ML MSF Frame MFManual Operation Frame MA Message Frame MESVP Starting ImplStatus Display Frame ST Cluster SSU Structure of a frame Subframes105 Page Contents Contents 109 101Page 111 S130 Business ServerOperating Manual Edition Jume