Replacing the Power Supply

Installing the 3000 W AC-Input Power Supply

Caution Use both hands to install and remove power supplies. Each Catalyst 6500 series AC-input power supply weighs between 22 pounds (9.9 kg) and 28 pounds (12.6 kg).

To install the 3000 W AC-input power supply, follow these steps:

Step 1 Ensure that the system (earth) ground connection has been made. For ground connection instructions, refer to the installation guide for your hardware platform.

Step 2 Verify that the power switch is in the Off (0) position on the power supply you are installing. (See Figure 7.)

Figure 7 3000 Watt AC-Input Power Supply Front Panel

AC power

connection

Cable

etention

 

 

 

 

 

 

 

 

device

 

 

 

 

 

 

 

 

 

 

110-120V - 15A

 

 

 

 

 

200-240V - 15A

 

 

 

 

 

60/50HZ

 

 

 

 

 

T

 

L

I

 

 

 

 

 

 

L

 

 

 

 

 

S

A

N

 

 

 

 

 

 

 

 

 

 

 

N

 

 

U

 

 

 

Power

I

 

 

R

 

 

 

O

 

 

 

 

 

 

 

switch

 

 

 

 

 

 

 

 

 

 

 

 

INPUT FAN

OUTPUT

 

 

 

 

 

 

OK

OK

FAIL

OUTPUT 42V /17A

42V

/17A

OK

105069

External power

Captive installation Status LEDs (3) connector cover screw

Step 3 Grasp the power supply handle with one hand. Place your other hand underneath the power supply, as shown in Figure 8. Slide the power supply into the power supply bay. Make sure that the power supply is fully seated in the bay.

Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note

12

78-16162-02

 

 

Image 12
Contents Product Number WS-6509-NEB-UPGRD= Contents Safety OverviewParts List Required ToolsInstallation Guidelines Shutting Down the SystemReplacing the Panel Safety Cover AC-Input SystemsPanel handle Installing the Panel Safety Cover Replacing the Fan TrayRemoving the Fan Tray Removing the Fan TrayInstalling the High Speed Fan Tray High Speed FANReplacing the Power Supply Removing an AC-Input Power SupplyRemoving an AC-Input Power Supply Installing the 3000 W AC-Input Power Supply 3000 Watt AC-Input Power Supply Front PanelConnecting Power to the Fan Tray Connecting Power to the Fan TrayInstalling the Fan Tray Power Cable for AC-Input Systems Cable ConnectorsConnecting Site Power to the Fan Tray for DC-Input Systems Terminal block coversRemoving the Terminal Block Cover Replacing the Supervisor Engine Removing the Supervisor EngineInstalling the Supervisor Engine Positioning the Supervisor Engine in the Chassis Clearing the EMI Gasket in the Chassis Powering Up the System AC-Input SystemsVerifying Installation DC-Input SystemsRelated Documentation Obtaining DocumentationCisco.com Product Documentation DVDDocumentation Feedback Cisco Product Security OverviewOrdering Documentation Reporting Security Problems in Cisco Products Obtaining Technical AssistanceSubmitting a Service Request Cisco Technical Support & Documentation WebsiteDefinitions of Service Request Severity Obtaining Additional Publications and InformationObtaining Additional Publications and Information