Chapter 1 Product Overview
Power Supplies
Power Supply Fan
Each power supply has a
Load-Sharing Feature
When you install and turn on a second power supply on a Catalyst 4500 series switch, it provides approximately
Note Load sharing works only when both power supplies in the chassis are the same type.
When you install a redundant power supply, load sharing and fault tolerance are enabled automatically; no additional software configuration is required.
Environmental Monitoring Feature
With the environmental monitoring and reporting feature, you can keep your system running by resolving adverse environmental conditions before loss of operation.
The power supply monitors its own internal temperature and voltages. In the event of excessive internal temperature, the power supply shuts down to prevent damage. When the power supply returns to a safe operating temperature, it restarts. If the power supply output voltage is not within the specified range, the LED labeled OUTPUT FAIL will light. An instance of substantial output overvoltage can shut down the power supply.
An instance of substantial input overvoltage (greater than
| Catalyst 4500 Series Switches Installation Guide |
|