Cisco Systems 4500 manual Power Connection Guidelines for AC-Powered Systems

Page 75

Chapter 2 Preparing for Installation

Power Connection Guidelines for AC-Powered Systems

Power Connection Guidelines for AC-Powered Systems

This section provides guidelines for connecting the Catalyst 4500 series switch AC power supplies to the site power source. Basic guidelines include the following:

Make sure each chassis power supply has its own dedicated branch circuit.

Size the circuits according to local and national codes.

If you are using a 200/240 VAC power source in North America, use a two-pole circuit breaker to protect the circuit.

Place the source AC outlet within 6 feet (1.8 meters) of the system and make sure it is easily accessible.

Make sure the AC power receptacles used to plug in the chassis are the grounding type. The grounding conductors that connect to the receptacles should connect to protective earth ground at the service equipment.

Four types of AC-input power supplies are available:

1000 W—Table2-1lists the AC-input power cord options, specifications, Cisco part numbers, and shows the different styles of 1000 W AC-input power cord wall plugs that are available for North America and international locations as well as the appliance coupler that is attached to the power supply end of the power cord.

1300 W—Table2-1lists the AC-input power cord options, specifications, and Cisco product numbers, and shows the different styles of 1300 W AC-input power cord wall plugs that are available for North America or various international locations as well as the appliance coupler that is attached to the power supply end of the power cord.

Note For North America, the power cord plug types and appliance couplers on the power supplies are different for the 1000 W power supplies and the 1300 W power supplies; for other countries, the plugs shown are the same for the 1000 W and 1300 W power supplies.

 

 

Catalyst 4500 Series Switches Installation Guide

 

 

 

 

 

 

78-14409-08

 

 

2-5

 

 

 

Image 75
Contents Catalyst 4500 Series Switches Installation Guide Page Catalyst 4500 Series Switches Installation Guide Page N T E N T S Load-Sharing Feature Removing and Replacing the Chassis Fan Assembly Serial Numbers Specifications Audience OrganizationChapter Title Description Related Documentation TroubleshootingConvention Description ConventionsArguments for which you supply values are in italic Varoitus Tärkeitä Turvallisuusohjeita Waarschuwing Belangrijke VeiligheidsinstructiesAvvertenza Importanti Istruzioni Sulla Sicurezza Warnung Wichtige SicherheitshinweiseAviso Instruções Importantes DE Segurança TA Vare PÅ Disse InstruksjoneneSpara Dessa Anvisningar Varning! Viktiga SäkerhetsanvisningarObtaining Documentation and Submitting a Service Request 78-14409-08 Product Overview Switch FeaturesCatalyst 4503 Switch Front View Catalyst 4503 Switch FeaturesFeature Description Feature Description Feature Description Catalyst 4506 Switch Front View Catalyst 4506 Switch FeaturesMore details on these modules Feature Feature Description Switching modules slots 3 through Catalyst 4507R Switch FeaturesFeature Description Feature Description Feature Description Feature Description 94936 Catalyst 4510R Switch Features10GE, any supported module may be used in slot Feature Description 78-14409-08 Feature Description Vlans Supervisor EnginesRmon Supervisor Engine II WS-X4013 Supervisor Engine II-Plus WS-X4013+ Supervisor Engine II-Plus 10GE WS-X4013+10GE 10 Supervisor Engine IV WS-X4515 12 Supervisor Engine V-10GE WS-X4516-10GE LEDs Gigabit Ethernet Uplink PortsColor/State Description SFP Ports CompactFlash Port Reset ButtonEthernet Management Port Console PortFan Assembly 13 Catalyst 4503 Airflow 15 Catalyst 4507R Airflow 16 Catalyst 4510R Airflow Captive screws Power switch AC receptacle Power Supplies18 4200 W Dual Input AC Power Supply 20 1400 W DC Triple-Input Power Supply Input OK Power Supply LEDsPower Supply Fan Load-Sharing FeatureEnvironmental Monitoring Feature DC Triple-input Power Supply Operational Modes Input Approximate Approximate InputNumber Input Current 12V Minimum Input Load Single Operation PSU1 PSU212V Minimum Input Load Dual Redundant Operation System Architecture Power FlowPower over Ethernet PoE Over-subscription Deploying PoE on the Cisco Catalyst 4500 Series Cisco Catalyst 4500 Series Service Provider DC Power Supply Management Flow Switching Traffic Flow Over-subscription Supervisor Redundancy Catalyst 4500 Series Switches Installation Guide Preparing for Installation Electrostatic Discharge Preventing Electrostatic Discharge Damage Site Power Requirements and Heat Dissipation Power Connection Guidelines for AC-Powered Systems Plug Type CouplerCAB-CEE77-C19-EU= Locale Part Number Length Plug Rating Plug TypeCAB-AC-2800W-TWLK= Appliance Coupler Power Supply PWR-C45-2800ACV= Appliance Coupler Power Supply PWR-C45-4200ACV= CAB-CEE77-C19-EU CAB-C19-CBN Power Connection Guidelines for DC-Powered Systems Calculating DC Input Current Ventilation Calculating System Heat Dissipation Output PowerTask No Planning Activity Verified by Time Site-Planning ChecklistTask No Planning Activity Verified by Time Date Installing the Switch in a Rack Installing the Switch in a Rack Checking the Shipping Container Contents Required Installation Tools Rack-Mounting the SwitchRack-Mounting Catalyst 4500 Series Switches Quantity Part Description L Brackets on the Front Edge of the Catalyst 4503 Switch L Brackets on the Front Edge of the Catalyst 4506 Switch L Brackets on the Front Edge of the Catalyst 4507R Switch L Brackets on the Front Edge of the Catalyst 4510R Switch Attaching the Cable Guide to the Catalyst 4503 Switch Attaching the Cable Guide to the Catalyst 4506 Switch Attaching the Cable Guide to the Catalyst 4507R Switch Attaching the Cable Guide to the Catalyst 4510R Switch Installing a Catalyst 4503 Switch in the Rack 10 Installing a Catalyst 4506 Switch in the Rack 11 Installing a Catalyst 4507R Switch in the Rack 12 Installing a Catalyst 4510R Switch in the Rack Grounding Holes System Ground Connection Guidelines14 Catalyst 4506 Grounding Holes 15 Catalyst 4507R Grounding Holes 16 Catalyst 4510R Grounding Holes Parts and Required Tools Connecting System Ground and Power 17 Connecting System Ground on the Switch 78-14409-08 Removing and Replacing FRUs Removing and Replacing the Power Supply AC-Input Power Supply DC-Input Power Supply Required Tools Removing an AC-Input Power SupplyLoosening the Side-Clamp Screw Handling an AC-Input Power Supply Installing an AC-Input Power Supply Plugging the Power Cord into the Power Supply 78-14409-08 Required Tools Removing a DC-Input Power Supply11 DC-Input Power Supply 13 Connecting the DC-Input Wires 15 Loosening the Captive Screws 16 Handling a DC-Input Power Supply Installation Procedure Installing a DC-Input Power Supply78-14409-08 Removing and Replacing the Chassis Fan Assembly 17 Catalyst 4503 System Fan Assembly 18 Catalyst 4506 System Fan Assembly 19 Catalyst 4507R System Fan Assembly 20 Catalyst 4510R System Fan Assembly Installing the Fan Assembly Removing the Fan AssemblyVerifying the Installation 78-14409-08 21 Catalyst 4507R Backplane 22 Finding the Seating Levers 24 Removing the Module Make sure the module is fully seated. See Figure Verify the New Modules Troubleshooting System Boot Verification Problem Solving to the System Component Level Using LEDs to Identify Startup Problems Troubleshooting Using LEDs to Identify Startup Problems Troubleshooting the Power Supply Troubleshooting Power Problems using Cisco IOS Troubleshooting the Fan Assembly Troubleshooting Backplane Modules Gigabit Ethernet Port and Status LEDs Troubleshooting Switching ModulesDiagnostic tests performed by the switch Troubleshooting Switching Modules Using Cisco IOS Troubleshooting Supervisor Engines Troubleshooting Supervisor Engines Using Cisco IOS Troubleshooting Troubleshooting Supervisor Engines Contacting the Cisco Technical Assistance Center SN Aaannnnxxxx Serial NumbersCatalyst 4506 Serial Number Location Catalyst 4507R Serial Number Location Catalyst 4510R Serial Number Location Specifications Specification Catalyst 4503 Switch SpecificationsCatalyst 4506 Switch Specifications Specification Right to left Front to back Catalyst 4507R Switch SpecificationsTable A-3 Catalyst 4507R Switch Specifications Catalyst 4510R Switch Specifications Table A-4 Catalyst 4510R Switch Specifications Catalyst 4500 Series Power Supplies Table A-5 AC-Input Power Supply Specifications Table A-6 AC-Input Power Supply Specifications Table A-8 1400 W DC-Input Power Supply Specifications Calculating DC Input Current section on Only Table A-9 DC Triple-Input Power Supply Specifications Two modules minimum required @ -40.5 VDC input PS1/PS2 Table A-12 AC-Input Power Supply Specifications Table A-13 AC-Input Power Supply Specifications @ 12 @3.3 @ -50 Maximum W 12V 50V TotalRepacking a Switch Figure B-1 Catalyst 4500 Series Switch Packing Material NumericsA IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8