Cisco Systems 3650 manual Enter a host name for the switch, and press Return

Page 92

Appendix C Configuring the Switch with the CLI-Based Setup Program

Entering the Initial Configuration Information

 

 

 

 

At any point you may enter a question mark '?' for help.

 

 

 

 

Use ctrl-c to abort configuration dialog at any prompt.

 

 

 

 

Default settings are in square brackets '[]'.

 

 

 

 

Basic management setup configures only enough connectivity

 

 

 

 

for management of the system, extended setup will ask you

 

 

 

 

to configure each interface on the system.

 

 

 

 

Would you like to enter basic management setup? [yes/no]: yes

 

 

 

Step 2

Enter a host name for the switch, and press Return.

 

 

 

 

On a command switch, the host name is limited to 28 characters and on a member switch to 31

 

 

 

 

characters. Do not use -n, where n is a number, as the last character in a host name for any switch.

 

 

 

 

Enter host name [Switch]: host_name

 

 

 

Step 3

Enter an enable secret password, and press Return.

 

 

 

 

The password can be from 1 to 25 alphanumeric characters, can start with a number, is case sensitive,

 

 

 

 

allows spaces, but ignores leading spaces. The secret password is encrypted, and the enable password is

 

 

 

 

in plain text.

 

 

 

 

Enter enable secret: secret_password

 

 

 

Step 4

Enter an enable password, and press Return.

 

 

 

 

Enter enable password: enable_password

 

 

 

Step 5

Enter a virtual terminal (Telnet) password, and press Return.

 

 

 

 

The password can be from 1 to 25 alphanumeric characters, is case sensitive, allows spaces, but ignores

 

 

 

 

leading spaces.

 

 

 

 

Enter virtual terminal password: terminal-password

 

 

 

Step 6

To configure the country code, enter yes and press Return.

 

 

 

 

Do you want to configure country code? [no]: yes

 

 

 

Step 7

Enter the country code, and press Return.

 

 

 

 

Enter the country code[US]:US

 

 

 

Step 8

(Optional) Configure Simple Network Management Protocol (SNMP) by responding to the prompts. You

 

 

 

 

can also configure SNMP later through the CLI, Device Manager, or the Cisco Network Assistant

 

 

 

 

application. To configure SNMP later, enter no.

 

 

 

 

Configure SNMP Network Management? [no]: no

 

 

 

Step 9

Enter the interface name (physical interface or VLAN name) of the interface that connects to the

 

 

 

 

management network, and press Return. For this release, always use vlan1 as that interface.

 

 

 

 

Enter interface name used to connect to the

 

 

 

 

management network from the above interface summary: vlan1

 

 

 

Step 10 Configure the interface by entering the switch IP address and subnet mask and pressing Return. The IP

 

 

 

 

address and subnet masks shown are examples.

 

 

 

 

Configuring interface vlan1:

 

 

 

 

Configure IP on this interface? [yes]: yes

 

 

 

 

IP address for this interface: 10.4.120.106

 

 

 

 

Subnet mask for this interface [255.0.0.0]: 255.0.0.0

 

 

 

Catalyst 3650 Switch Hardware Installation Guide

 

 

 

 

 

 

 

 

 

 

C-6

 

 

OL-29734-01

 

 

 

 

 

Image 92
Contents Document Conventions PrefacePurpose Obtaining Documentation and Submitting a Service Request Related DocumentationProduct Overview Switch ModelsSwitch Model Cisco IOS Image Description Product Overview Switch Models Switch Model Cisco IOS Image Description Front Panel Catalyst 3650-48PD-L Switch Front Panel Management Ports 10/100/1000 Ethernet PortsPoE and PoE+ USB Type a Port USB Mini-Type B PortSFP and SFP+ Modules Uplink PortsLEDs 3 4 5 Color System StatusMode LED Port Mode Description Port LEDs and ModesPort Mode Port LED Color Meaning USB Console LED ColorPoE+ LED Color DescriptionUplink Ports LEDs Color PoE+ StatusRear Panel Color Uplink Ports Link StatusRJ-45 Console Port Status1 RJ-45 Console Port LEDStackWise Ports Power Supply Modules Models Default Power Supply Available PoE Power PoE Option Port SwitchAC-Power Supply Module LEDs ModelsDC-Power Supply Module LEDs Fan ModulesRJ-45 Console Port Management OptionsEthernet Management Port Network Configurations OL-29734-01 Safety Warnings Switch InstallationPreparing for Installation OL-29734-01 Installation Guidelines Planning a Switch Data Stack Verifying Switch OperationPowering Off the Switch Tools and EquipmentSwitch Stacking Guidelines Data Stack Cabling ConfigurationsData Stacking up to Four Switches in a Side-by-Side Mounting Data Stack Bandwidth and Partitioning ExamplesPower-On Sequence for Switch Data Stacks Example of a Data Stack with Half Bandwidth ConnectionsChanges to Switch Stack Membership Installing the Switch Rack-Mounting Attaching the Rack-Mount Brackets Rack-Mounting BracketsAttaching Brackets for 19-inch Racks Mounting the Switch in a Rack Mounting the Switch in a RackAfter Installing the Switch Table- or Shelf-MountingConnecting to the StackWise Ports Installing the StackWise Adapter in a StackWise Port Installing and Removing SFP and SFP+ Modules Installing SFP and SFP+ Modules14 Installing an SFP Module in an Uplink Port 10/100/1000 Ethernet Port Connections Connecting Devices to the Ethernet PortsRemoving SFP or SFP+ Modules Switch Installation Connecting Devices to the Ethernet Ports PoE+ Port Connections Device Crossover CableWhere to Go Next Part Number Description Power Supply InstallationPower Supply Module Overview AC OK LED 640-W AC Power Supply Module 6 5 DC Power Supply Module LEDs Installation GuidelinesAC Power Supply Module LEDs Installing or Replacing an AC Power Supply Installing a DC Power Supply StatementGrounding the Switch Equipment That You NeedStripping the Ground Wire 10 Attaching the Ground Lug and Wire Assembly Installing the DC Power Supply in the Switch Wiring the DC Input Power SourceFinding the Power Supply Module Serial Number 12 DC Source a Isolated From Source B with No Common Ground14 1025-W AC Power Supply Serial Number 16 640-W DC Power Supply Module Serial Number Installing the Fan OverviewFan Module Installation Installing a Fan Module Fan LEDFinding the Fan Module Serial Number Fan Module Serial NumberTroubleshooting Diagnosing ProblemsSwitch Post Results Switch LEDsSwitch Connections Bad or Damaged CableEthernet and Fiber Cables Link StatusSFP Modules 10/100/1000 Port ConnectionsPoE and PoE+ Port Connections Switch Performance Interface SettingsPing End Device Spanning Tree LoopsCabling Distance Resetting the SwitchAutonegotiation and Network Interface Cards Finding the Switch Serial Number Replacing a Failed Data Stack MemberEnvironmental Ranges Technical SpecificationsSwitch Specifications Physical Specifications Power Supply Module Specifications Power SpecificationsPower Specifications Operating Specification Fan Module SpecificationsPhysical Specification OL-29734-01 10/100/1000 Ports Connector and Cable SpecificationsConnector Specifications Gigabit Ethernet CX1 SFP+ Copper Connectors SFP and SFP+ ModulesFigure B-4 Simplex LC Cable Connector 10/100/1000 Ethernet Management PortConsole Port Figure B-7 10/100 Port PinoutsCable and Adapter Specifications StackWise CablesStackWise Adapters StackWise Cables Minimum Bend Radius and Coiled DiameterLocating the StackWise Adapter Serial Number Cable Part Number Cable Length Minimum Bend RadiusSFP and SFP+ Module Cable Specifications StackWise Adapter BlanksFour Twisted-Pair Cable Pinouts Two Twisted-Pair Cable PinoutsSwitch Console RJ-45-to-DB-9 Port DTE Identifying a Crossover CableConsole Port Adapter Pinouts DeviceSwitch Console RJ-45-to-DB-25 Port DTE DSR DTR CTS RTSConfiguring the Switch with the CLI-Based Setup Program Accessing the CLIAccessing the CLI Through Express Setup Accessing the CLI Through a Console PortUSB Console Port Installing the Cisco Microsoft Windows USB Device Driver Uninstalling the Cisco Microsoft Windows USB Driver Uninstalling the Cisco Microsoft Windows XP USB DriverConfiguring the Setup Program Entering the Initial Configuration InformationIP Settings Enter a host name for the switch, and press Return These choices appear OL-29734-01