Cisco Systems 3650 manual Power Specifications

Page 74

Appendix A Technical Specifications

Power Supply Module Specifications

Table A-3 Power Specifications for AC Power 24- and 48-Port Switches (continued)

Total input BTU1

PWR-C2-1025WAC: 3801 BTUs per hour, 1114 W

 

PWR-C2-640WAC: 2371 BTUs per hour, 695 W

 

PWR-C2-250WAC: 945 BTUs per hour, 277 W

 

 

Total output BTU1

PWR-C2-1025WAC: 3497 BTUs per hour, 1025 W

 

PWR-C2-640WAC: 2183 BTUs per hour, 640 W

 

PWR-C2-250WAC: 853 BTUs per hour, 250 W

 

 

1.The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on 100 VAC for the 250-W and 640-W power supplies and 115 VAC for the 1100-W power supply.

Table A-4

Power Specifications for DC-Power 24- and 48-Port Switches

 

 

Power Specifications

 

 

 

Maximum output power

PWR-C2-640WDC: 640 W

 

 

 

Input current

 

PWR-C2-640WDC: 21–10.5 A

 

 

DC input voltage

PWR-C2-640WDC: –36 to –72 VDC

 

 

 

Output ratings

 

PWR-C2-640WDC: +12 V @ 20.83 A, –54 V@7.36 A

 

 

Voltage range domestic

PWR-C2-640WDC: –36 VDC (minimum)

 

 

–48 VDC (nominal), –72 VDC (maximum)

 

 

Voltage range international

PWR-C2-640WDC: –36 VDC (minimum)

 

 

–60 VDC (nominal), –72 VDC (maximum)

 

 

Total input BTU1

PWR-C2-640WDC 2444 BTUs per hour, 719 W

Total output BTU1

PWR-C2-640WDC: 2188 BTUs per hour, 640 W

Wire gauge for ground connection

PWR-C2-640WDC: 12 AWG or 8 AWG

 

 

Branch circuit protection

PWR-C2-640WDC: 25 A

 

 

 

1.The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on –48 VDC (nominal).

Catalyst 3650 Switch Hardware Installation Guide

 

A-4

OL-29734-01

 

 

 

Image 74
Contents Document Conventions PrefacePurpose Obtaining Documentation and Submitting a Service Request Related DocumentationProduct Overview Switch ModelsSwitch Model Cisco IOS Image Description Product Overview Switch Models Switch Model Cisco IOS Image Description Front Panel Catalyst 3650-48PD-L Switch Front Panel Management Ports 10/100/1000 Ethernet PortsPoE and PoE+ USB Type a Port USB Mini-Type B PortSFP and SFP+ Modules Uplink PortsLEDs 3 4 5 Color System StatusMode LED Port Mode Description Port LEDs and ModesPort Mode Port LED Color Meaning USB Console LED ColorPoE+ LED Color DescriptionUplink Ports LEDs Color PoE+ StatusRear Panel Color Uplink Ports Link StatusRJ-45 Console Port Status1 RJ-45 Console Port LEDStackWise Ports Power Supply Modules AC-Power Supply Module LEDs Models Default Power Supply Available PoE PowerPoE Option Port Switch ModelsDC-Power Supply Module LEDs Fan ModulesRJ-45 Console Port Management OptionsEthernet Management Port Network Configurations OL-29734-01 Safety Warnings Switch InstallationPreparing for Installation OL-29734-01 Installation Guidelines Powering Off the Switch Planning a Switch Data StackVerifying Switch Operation Tools and EquipmentSwitch Stacking Guidelines Data Stack Cabling ConfigurationsData Stacking up to Four Switches in a Side-by-Side Mounting Data Stack Bandwidth and Partitioning ExamplesPower-On Sequence for Switch Data Stacks Example of a Data Stack with Half Bandwidth ConnectionsChanges to Switch Stack Membership Installing the Switch Rack-Mounting Attaching the Rack-Mount Brackets Rack-Mounting BracketsAttaching Brackets for 19-inch Racks Mounting the Switch in a Rack Mounting the Switch in a RackAfter Installing the Switch Table- or Shelf-MountingConnecting to the StackWise Ports Installing the StackWise Adapter in a StackWise Port Installing and Removing SFP and SFP+ Modules Installing SFP and SFP+ Modules14 Installing an SFP Module in an Uplink Port 10/100/1000 Ethernet Port Connections Connecting Devices to the Ethernet PortsRemoving SFP or SFP+ Modules Switch Installation Connecting Devices to the Ethernet Ports PoE+ Port Connections Device Crossover CableWhere to Go Next Part Number Description Power Supply InstallationPower Supply Module Overview AC OK LED 640-W AC Power Supply Module 6 5 DC Power Supply Module LEDs Installation GuidelinesAC Power Supply Module LEDs Installing or Replacing an AC Power Supply Installing a DC Power Supply StatementGrounding the Switch Equipment That You NeedStripping the Ground Wire 10 Attaching the Ground Lug and Wire Assembly Installing the DC Power Supply in the Switch Wiring the DC Input Power SourceFinding the Power Supply Module Serial Number 12 DC Source a Isolated From Source B with No Common Ground14 1025-W AC Power Supply Serial Number 16 640-W DC Power Supply Module Serial Number Installing the Fan OverviewFan Module Installation Installing a Fan Module Fan LEDFinding the Fan Module Serial Number Fan Module Serial NumberSwitch Post Results TroubleshootingDiagnosing Problems Switch LEDsEthernet and Fiber Cables Switch ConnectionsBad or Damaged Cable Link StatusSFP Modules 10/100/1000 Port ConnectionsPoE and PoE+ Port Connections Ping End Device Switch PerformanceInterface Settings Spanning Tree LoopsCabling Distance Resetting the SwitchAutonegotiation and Network Interface Cards Finding the Switch Serial Number Replacing a Failed Data Stack MemberEnvironmental Ranges Technical SpecificationsSwitch Specifications Physical Specifications Power Supply Module Specifications Power SpecificationsPower Specifications Operating Specification Fan Module SpecificationsPhysical Specification OL-29734-01 10/100/1000 Ports Connector and Cable SpecificationsConnector Specifications Gigabit Ethernet CX1 SFP+ Copper Connectors SFP and SFP+ ModulesFigure B-4 Simplex LC Cable Connector 10/100/1000 Ethernet Management PortConsole Port Figure B-7 10/100 Port PinoutsCable and Adapter Specifications StackWise CablesLocating the StackWise Adapter Serial Number StackWise AdaptersStackWise Cables Minimum Bend Radius and Coiled Diameter Cable Part Number Cable Length Minimum Bend RadiusSFP and SFP+ Module Cable Specifications StackWise Adapter BlanksFour Twisted-Pair Cable Pinouts Two Twisted-Pair Cable PinoutsConsole Port Adapter Pinouts Switch Console RJ-45-to-DB-9 Port DTEIdentifying a Crossover Cable DeviceSwitch Console RJ-45-to-DB-25 Port DTE DSR DTR CTS RTSAccessing the CLI Through Express Setup Configuring the Switch with the CLI-Based Setup ProgramAccessing the CLI Accessing the CLI Through a Console PortUSB Console Port Installing the Cisco Microsoft Windows USB Device Driver Uninstalling the Cisco Microsoft Windows USB Driver Uninstalling the Cisco Microsoft Windows XP USB DriverConfiguring the Setup Program Entering the Initial Configuration InformationIP Settings Enter a host name for the switch, and press Return These choices appear OL-29734-01