Cisco Systems SLM248G4PS manual Back Panel, Power The Power port is where you connect the AC power

Page 9

Chapter 2

Back Panel

The Console port and power port are located on the back panel of the Switch.

Back Panel of the SLM248G4PS

CONSOLE  The Console port is a serial port that allows you to connect to a computer’s serial port (for configuration purposes) using the provided serial cable. You can use HyperTerminal to manage the Switch using the console port.

POWER  The Power port is where you connect the AC power.

SLM224G4PS

Front Panel

The Switch’s LEDs and ports are located on the front panel.

Front Panel of the SLM224G4PS

System  (Green/Amber)  Lights up green to indicate that the Switch is powered on.

Lights up amber while the Switch is performing a system self-test. Blinks amber if the self-test fails.

LINK/ACT (1-24) (Green) Lights up to indicate a functional 10/100 Mbps network link through the corresponding port (1 through 24) with an attached device. Blinks while the Switch is actively sending or receiving data over that port.

PoweroverEthernet(1-6,13-18)  (Amber)  Lights up to indicate that power is being supplied to an attached powered device on the corresponding port (1 through 6, or 13 through 18).

LINK/ACT (G1-G4) (Green) Blinks when the Switch is actively sending or receiving data over the corresponding port (G1 through G4).

1000M (G1-G4) (Yellow) Lights up to indicate a functional1 Gbpsconnectiononthecorresponding port (G1 through G4) with an attached device.

Product Overview

Stack (G1-G4) (Amber)  Lights up to indicate that the corresponding port (G1 through G4) is linked to another switch. (Two of these LEDs will be lit if switch stacking is properly configured.)

Ethernet 1-24 The Switch is equipped with 24 auto-sensing, Ethernet network ports, which use RJ-45 connectors. The Fast Ethernet ports support network speeds of 10 Mbps or 100 Mbps. They can operate in half- and full-duplex modes. Auto-sensing technology enables each port to automatically detect the speed of the device connected to it (10 Mbps or 100 Mbps), and adjust its speed and duplex accordingly.

G1-G4 The Switch is equipped with 4 auto- sensing Gigabit Ethernet network ports, which use RJ-45 connectors. The Gigabit Ethernet ports support network speeds of 10 Mbps, 100 Mbps, or 1000 Mbps. They can operate in half- and full-duplex modes. Auto-sensing technology enables each port to automatically detect the speed of the device connected to it (10 Mbps, 100 Mbps, or 1000 Mbps), and adjust its speed and duplex accordingly.

miniGBIC (1-2) The miniGBIC (gigabit interface converter) port is a connection point for a miniGBIC expansion module, so the Switch can be uplinked via fiber to another switch. The MiniGBIC port provides a link to a high-speed network segment or individual workstation at speeds of up to 1000 Mbps.

To establish a Gigabit Ethernet connection using a miniGBIC port, you will need to install a MGBT1, MGBSX1, or MGBLH1 Gigabit expansion module and use Category 5e cabling or fiber optic cabling.

To establish a Fast Ethernet connection using a miniGBIC port, you will need to install a MFEFX1 (100BASE-FX) or MFELX1 (100BASE-LX) 100SFP Transceiver and use fiber optic cabling.

Stack ID  Displays the Switch’s unit ID number if the Switch is in stack mode.

Stack Master  (Amber) Lights up if the switch is the stack Master during stack mode.

NOTE:  On the SLM224G4PS, MiniGBIC ports are shared with standard ports. If a miniGBIC port is used, then the shared standard port on the Switch cannot be used. The following table defines the shared port mapping of the SLM224G4PS Switch.

24/48-Port 10/100 + 4-Port Gigabit Smart Switch with Resilient Clustering Technology and PoE

Image 9
Contents Port or 48-Port 10/100 + About This Guide About This GuideIcon Descriptions Online ResourcesTable of Contents Snmp Global Parameters Snmp Views Snmp Group Profile SnmpGigabit Ethernet Fiber Optic Cabling Appendix B About Switch StackingAppendix G Contact Information Appendix C Glossary Appendix D SpecificationsIntroduction ChapterChapter Product Overview Switch LEDs and ports are located on the front panelProduct Overview Front PanelPower The Power port is where you connect the AC power Switch’s LEDs and ports are located on the front panelBack Panel Product Overview Installation Chapter InstallationPre-Installation Considerations Placement OptionsHardware Installation Desktop PlacementRack-Mount Placement Uplinking the Switch Configuring Stack ModeTo set up a stack with six switches, follow these steps Power off the new unit 5 the former master unit Connect port G1 on Unit 2 to port G2 on UnitConnect port G1 on Unit 3 to port G2 on Unit Chapter Configuration Using Console Interface Using telnetLogin screen appears. Proceed to the Login section below Login How to Use the Console InterfaceSwitch Main Menu System Configuration MenuSystem Information Management SettingsUser & Password Settings Security SettingsIP Configuration Http Reboot System Restore System Default SettingsStack Configuration File ManagementPort Status Menu Port ConfigurationPoE Settings System ModeHelp LogoutSetup Chapter Configuration Using Web-based UtilitySetup Summary Device InformationSetup Network Settings Setup ZoomOrange The administrator has closed down this port Clicking on a port displays the Port Configuration screenSet Time Setup TimeLocal Time Daylight SavingPort Management Port Settings Setup Stack ManagementPort Management Sntp ServersPort Management Port Settings Port Configuration Port Management Link Aggregation LAG ConfigurationPort Management Lacp Port Management PoE Power SettingsVlan Management Vlan Management Port SettingVlan Management Create Vlan Vlan TableVlan Management Port to Vlan Vlan Management Vlan to PortJoin Vlan to Port Statistics Statistics Rmon StatisticsStatistics Rmon History Rmon History Log TableRmon History Table Statistics Rmon Alarms Add AlarmAlarm Table Statistics Rmon Events Statistics Port UtilizationStatistics Interface Statistics Security Security 802.1x SettingsEthernet-like ParametersSecurity Port Security Setting TimerSecurity Storm Control Security Management Access ListQoS Security RadiusBroadcast Only Counts only Broadcast traffic QoS Queue Settings QoS CoS SettingsCoS Settings CoS DefaultQoS Dscp Settings QoS Basic ModeQoS Bandwidth Spanning Tree Global SettingSpanning Tree STP Status Spanning Tree Global STPSpanning Tree STP Port Settings Bridge SettingsSpeed Displays the speed at which the port is operating Multicast Vlan Igmp SettingsMulticast Igmp Snooping Multicast Bridge MulticastSnmp Global Parameters Multicast Bridge Multicast Forward AllSnmp Group Profile Snmp ViewsSnmp Group Membership Snmp CommunitiesUser Name Provides a user-defined local user list Snmp Notification Recipient Snmp Notification FilterBase Table Advanced TableAdmin User Authentication AdminUser Authentication Local User EditAdmin Static Address Admin Dynamic AddressSecure The entry is defined for locked ports Admin Cable Test Admin Port MirroringQuery Clear Table If selected, this clears the MAC Address tableAdmin Save Configuration Admin Firmware Upgrade Admin RebootAdmin Factory Default Admin Logging Admin Server LogsAdmin Memory Logs Logout Admin Flash LogsAppendix a About Gigabit Ethernet Fiber Optic Cabling Appendix aGigabit Ethernet Fiber Optic CablingAbout Switch Stacking Appendix B About Switch StackingAppendix B Stack Building Quick StartStack Resiliency Advanced StackingUnit IDs Unit ID AllocationStack Units Startup Process Master DiscoveryMaster Election User Controls Unit and Port ConfigurationStacking Examples Replacing a Failed Stack Member in a Running StackStack Master Failure and Replacement Splitting a Stack Subgroup Contains Both Master Unit and Backup Master UnitBoth Stacks Kept Running During Insertion Merging Two StacksInserting Too Many Units Stacking Cable FailureAppendix C Appendix C GlossaryGlossary Glossary Mail protocol on the Internet Packet a unit of data sent over a networkAppendix C Appendix D Specifications SpecificationsAppendix D Power in compliance with Ieee Class of Service Port-based 802.1p Vlan priority-basedDimensions Management VlanObtaining Warranty Service Warranty InformationAppendix E Exclusions and LimitationsTechnical Support Warranty InformationRegulatory Information Appendix FRegulatory Information Appendix F Norsk Norwegian Miljøinformasjon for kunder i EU Appendix F Contact Information Appendix G