Oversize Packets  Displays the number of oversized packets (over 1518 octets) received on the interface since the device was last refreshed.

Fragments  Displays the number of fragments (packets with less than 64 octets, excluding framing bits, but including FCS octets) received on the interface since the device was last refreshed.

Jabbers  Displays the total number of received packets that were longer than 1518 octets. This number excludes frame bits, but includes FCS octets that had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral octet (Alignment Error) number. The field range to detect jabbers is between 20 ms and 150 ms.

Collisions  Displays the number of collisions received on the interface since the device was last refreshed.

Utilization  Displays the percentage of the interface utilized.

Statistics > RMON Alarms

The RMON Alarm screen is used to set network alarms. Network alarms occur when a network problem, or event, is detected. Rising and falling thresholds generate events.

Statistics > RMON Alarm

Add Alarm

Alarm Entry  Indicates a specific alarm.

Interface  Indicates the interface for which RMON statistics are displayed. To specify the interface, select Unit No. (default) and specify the unit number and port from the drop-down menus, or select LAG and select the LAG number from the drop-down menu.

Counter Name  Displays the selected MIB variable.

Sample Type  Defines the sampling method for the selected variable and comparing the value against the thresholds. The possible field values are:

Absolute  Compares the values directly with the thresholds at the end of the sampling interval.

Delta  Subtracts the last sampled value from the current value. The difference in the values is compared to the threshold.

Rising Threshold  Displays the rising counter value that triggers the rising threshold alarm. The rising threshold is presented on top of the graph bars. Each monitored variable is designated a color.

Rising Event  Displays the mechanism in which the alarms are reported. The possible field values are:

LOG  Indicates there is not a saving mechanism for either the device or in the management system. If the device is not reset, the entry remains in the Log Table.

TRAP  Indicates that an SNMP trap is generated, and sent via the Trap mechanism. The Trap can also be saved using the Trap mechanism.

Both  Indicates that both the Log and Trap mechanism are used to report alarms.

Falling Threshold  Displays the falling counter value that triggers the falling threshold alarm. The falling threshold is graphically presented on top of the graph bars. Each monitored variable is designated a color.

Falling Event  Displays the mechanism in which the alarms are reported. The possible field values are:

LOG  Indicates there is not a saving mechanism for either the device or in the management system. If the device is not reset, the entry remains in the Log Table.

TRAP  Indicates that a SNMP trap is generated, and sent via the Trap mechanism. The Trap can also be saved using the Trap mechanism.

Both  Indicates that both the Log and Trap mechanism are used to report alarms.

Startup Alarm  Displays the trigger that activates alarm generation. Rising is defined by crossing the threshold from a low-value threshold to a higher-value threshold.

Interval  Defines the alarm interval time in seconds. Owner  Displays the device or user that defined the alarm. Click Add to List to add an entry to the Alarm Table.

Alarm Table

The Alarm Table lists the alarms that have been defined using the Add Alarm section. The Alarm Table contains a colunn for each field in the Add Alarm section, plus the following column:

Counter Value  Displays the current counter value for the particular alarm.

24/48-Port 10/100 + 4-Port Gigabit Smart Switch with Resilient Clustering Technology and PoE

28

Image 34
Contents Port or 48-Port 10/100 + Icon Descriptions About This GuideAbout This Guide Online ResourcesTable of Contents Snmp Snmp Global Parameters Snmp Views Snmp Group ProfileAppendix B About Switch Stacking Gigabit Ethernet Fiber Optic CablingAppendix C Glossary Appendix D Specifications Appendix G Contact InformationChapter IntroductionProduct Overview Switch LEDs and ports are located on the front panelChapter Product Overview Front PanelSwitch’s LEDs and ports are located on the front panel Power The Power port is where you connect the AC powerBack Panel Product Overview Pre-Installation Considerations Chapter InstallationInstallation Placement OptionsDesktop Placement Hardware InstallationRack-Mount Placement Configuring Stack Mode Uplinking the SwitchTo set up a stack with six switches, follow these steps Connect port G1 on Unit 2 to port G2 on Unit Power off the new unit 5 the former master unitConnect port G1 on Unit 3 to port G2 on Unit Using telnet Chapter Configuration Using Console InterfaceLogin screen appears. Proceed to the Login section below Switch Main Menu How to Use the Console InterfaceLogin System Configuration MenuManagement Settings System InformationSecurity Settings User & Password SettingsIP Configuration Http Stack Configuration Restore System Default SettingsReboot System File ManagementPort Configuration Port Status MenuHelp System ModePoE Settings LogoutSetup Summary Chapter Configuration Using Web-based UtilitySetup Device InformationOrange The administrator has closed down this port Setup ZoomSetup Network Settings Clicking on a port displays the Port Configuration screenLocal Time Setup TimeSet Time Daylight SavingPort Management Setup Stack ManagementPort Management Port Settings Sntp ServersPort Management Port Settings Port Configuration LAG Configuration Port Management Link AggregationPort Management PoE Power Settings Port Management LacpVlan Management Create Vlan Vlan Management Port SettingVlan Management Vlan TableVlan Management Vlan to Port Vlan Management Port to VlanJoin Vlan to Port Statistics Rmon Statistics StatisticsStatistics Rmon History Log Table Rmon HistoryRmon History Table Add Alarm Statistics Rmon AlarmsAlarm Table Statistics Port Utilization Statistics Rmon EventsStatistics Interface Statistics Ethernet-like Security 802.1x SettingsSecurity ParametersSetting Timer Security Port SecuritySecurity Management Access List Security Storm ControlSecurity Radius QoSBroadcast Only Counts only Broadcast traffic CoS Settings QoS CoS SettingsQoS Queue Settings CoS DefaultQoS Basic Mode QoS Dscp SettingsQoS Bandwidth Spanning Tree STP Status Global SettingSpanning Tree Spanning Tree Global STPBridge Settings Spanning Tree STP Port SettingsSpeed Displays the speed at which the port is operating Multicast Igmp Snooping Vlan Igmp SettingsMulticast Multicast Bridge MulticastMulticast Bridge Multicast Forward All Snmp Global ParametersSnmp Views Snmp Group ProfileSnmp Communities Snmp Group MembershipUser Name Provides a user-defined local user list Base Table Snmp Notification FilterSnmp Notification Recipient Advanced TableUser Authentication AdminAdmin User Authentication Local User EditAdmin Dynamic Address Admin Static AddressSecure The entry is defined for locked ports Query Admin Port MirroringAdmin Cable Test Clear Table If selected, this clears the MAC Address tableAdmin Save Configuration Admin Reboot Admin Firmware UpgradeAdmin Factory Default Admin Server Logs Admin LoggingAdmin Memory Logs Admin Flash Logs LogoutGigabit Ethernet Appendix aAppendix a About Gigabit Ethernet Fiber Optic Cabling Fiber Optic CablingAppendix B Appendix B About Switch StackingAbout Switch Stacking Stack Building Quick StartUnit IDs Advanced StackingStack Resiliency Unit ID AllocationMaster Discovery Stack Units Startup ProcessMaster Election Stacking Examples Unit and Port ConfigurationUser Controls Replacing a Failed Stack Member in a Running StackStack Master Failure and Replacement Subgroup Contains Both Master Unit and Backup Master Unit Splitting a StackMerging Two Stacks Both Stacks Kept Running During InsertionStacking Cable Failure Inserting Too Many UnitsAppendix C Glossary Appendix CGlossary Glossary Packet a unit of data sent over a network Mail protocol on the InternetAppendix C Specifications Appendix D SpecificationsAppendix D Dimensions Class of Service Port-based 802.1p Vlan priority-basedPower in compliance with Ieee Management VlanAppendix E Warranty InformationObtaining Warranty Service Exclusions and LimitationsWarranty Information Technical SupportAppendix F Regulatory InformationRegulatory Information Appendix F Norsk Norwegian Miljøinformasjon for kunder i EU Appendix F Appendix G Contact Information