Cisco Systems PA-2E3, PA-E3 Performing a Basic Configuration, Performing a Basic Configuration

Page 53

Performing a Basic Configuration

Slots in the Cisco 7140 series routers are numbered as shown Figure 8-6. The fixed LAN interface is slot 0, the fixed WAN interfaces are slots 1 and 2, and the modular port adapter interface is slot 4. Slot 3 is not used. Slot 5 is the service module.

Figure 8-6 Port Adapter Slot Numbering—Cisco 7140 Series

Slot 5

Slot 4

BOOT

SM-EC-DS

RESET ERROR

5 EN

IRX 155 - MM TX

ENRX

CEL CAR ALM

SLOT 0

SLOT 1

 

 

 

 

 

 

 

 

 

ACT

ACT

 

 

 

 

 

 

 

 

 

 

LNK

LNK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

 

FE 0 / 0 FE 0 / 1

 

155 - MM

 

 

 

 

 

 

 

 

 

 

RX TX

EN

RX

CEL CAR ALM

 

 

 

 

 

 

 

 

 

PWR

 

 

 

 

 

 

 

 

 

SYS

 

 

 

 

 

 

 

 

 

CONS

 

 

 

AUX

RDY

7140 - 2MM3

 

AC OK

 

 

DC OK

 

 

OTF

 

0

 

 

 

AC OK

 

 

DC OK

 

 

OTF

18499

2

 

 

 

Slot 1

Slot 0 Slot 2

Performing a Basic Configuration

The following steps are for a basic interface configuration for the PA-E3. Press the Return key after each step unless otherwise noted. At any time you can exit the privileged level and return to the user level by entering disable at the prompt:

router# disable

router>

Step 1 At the privileged-level prompt, enter configuration mode and specify that the console terminal is the source of the configuration subcommands:

router# configure terminal

Enter configuration commands, one per line. End with CNTL/Z. router(config)#

Step 2 Specify the interface to configure:

For Cisco 7100 series, Cisco 7200 series, or Cisco uBR7200 series routers, specify the interface to configure by entering the subcommand interface serial followed by the slot/port (port adapter slot number and interface port number). The example that follows is for the interface of the port adapter in slot 3:

router(config)# interface serial 3/0

For a VIP2, specify the interface to configure by entering the subcommand interface serial, followed by the slot/port-adapter/port(interface processor slot number, port adapter slot number, and interface port number). The example that follows is for the interface of the first port adapter on a VIP2 in interface processor slot 1:

router(config)# interface serial 1/0/0

For a Catalyst RSM/VIP2, specify the interface to configure by entering the subcommand interface serial, followed by the port-adapter/port(port adapter slot number and interface port number). The example that follows is for the interface of the first port adapter on a Catalyst RSM/VIP2:

router(config)# interface serial 0/0

Configuring the PA-E3 Interfaces 8-7

Image 53
Contents Corporate Headquarters PA-E3 Serial Port Adapter Installation and ConfigurationPage Objectives PrefaceOrganization Section Title DescriptionRelated Documentation Section Title Description Related DocumentationRelated Documentation Cisco Connection Online Cisco Connection OnlineDocumentation CD-ROM Port Adapter Overview OverviewOne-Port PA-E3 Serial Port Adapter Port Adapter OverviewPA-E3 Serial Port Adapter Features PA-E3 Serial Port Adapter FeaturesManagement Information Base PA-E3 Port Adapter LEDsPA-E3 Receptacles and Cables PA-E3 Receptacles and CablesPA-E3 Port Adapter LEDs Name Color State DescriptionInteroperability Guidelines for PA-E3 DSUs 6PA-E3 Serial Port Adapter Installation and Configuration Parts and Tools Required Preparing for InstallationPA-2E3 Software and Hardware RequirementsSoftware and Hardware Requirements Safety Guidelines Safety Guidelines4PA-E3 Serial Port Adapter Installation and Configuration Electrical Equipment Guidelines Telephone Wiring GuidelinesPreventing Electrostatic Discharge Damage Electrical Equipment GuidelinesBabt Compliance Compliance InformationITI-T Compliance TBR24 ComplianceOverview VIP2 and the PA-E3Dimm U5 OverviewPA-E3 in port adapter Slot PA-E3 in port adapter slot Removing a Port Adapter Removing a Port AdapterInstalling a Port Adapter Installing a Port AdapterAligning a Port Adapter in a Port Adapter Slot H3152 8PA-E3 Serial Port Adapter Installation and Configuration Catalyst RSM/VIP2 and the PA-E3 Port adapter securing screw Removing a Port Adapter Installing a Port Adapter Aligning a Port Adapter in a Port Adapter Slot 6PA-E3 Serial Port Adapter Installation and Configuration Cisco 7206 with a PA-E3 in Port Adapter Slot Cisco 7200 Series and the PA-E3Port adapter Handle Lever unlocked Position Handling a Port Adapter Port adapter Handle Cisco uBR7200 Series and the PA-E3 Port adapters Port adapters Port adapter lever in unlocked position Inside slot guide PC board Metal carrier Port adapter retention clip in locked position 6PA-E3 Serial Port Adapter Installation and Configuration Cisco 7100 Series and the PA-E3 Installation OverviewCisco 7140 Series Router-Port Adapter Slot 4 Location Installing a Port Adapter Guides Using the Exec Command Interpreter Configuring the PA-E3 InterfacesCisco 7200 Series and Cisco uBR7200 Series Ports Cisco 7206 Serial Port Number Example Cisco 7200 Series and Cisco uBR7200 Series PortsPA-E3 Interface Port Address Example- Cisco uBR7246 Shown VIP2 PortsCatalyst RSM/VIP2 Ports Catalyst RSM/VIP2 PortsWith port adapters Route Switch ModuleCisco 7100 Series Ports Performing a Basic Configuration Performing a Basic ConfigurationCustomizing the PA-E3 Configuration ExampleConfiguration Example Defining the DSU Mode Setting the BandwidthSetting the Bandwidth Defining Set Bit NationalConfiguring Cyclic Redundancy Checks Setting the Cable LengthConfiguring Cyclic Redundancy Checks Specifying E3 FramingChecking the Configuration Using show Commands to Verify StatusChecking the Configuration Number Checking the Configuration StepRouter# show interfaces serial 2/0 14PA-E3 Serial Port Adapter Installation and Configuration Router# show controllers serial 0/1 Serial0/1 16PA-E3 Serial Port Adapter Installation and Configuration 73-1684-03 18PA-E3 Serial Port Adapter Installation and Configuration Using the ping Command to Verify Network Connection Using the ping Command to Verify Network ConnectionUsing the loopback Command to Verify the Physical Interface Using the loopback Command to Verify the Physical Interface 22PA-E3 Serial Port Adapter Installation and Configuration