Cisco Systems PA-2E3 manual 14PA-E3 Serial Port Adapter Installation and Configuration

Page 60

Checking the Configuration

Output queue 0/40, 0 drops; input queue 0/75, 0 drops 5 minute input rate 0 bits/sec, 0 packets/sec

5 minute output rate 0 bits/sec, 0 packets/sec

0 packets input, 0 bytes, 0 no buffer

Received 0 broadcasts, 0 runts, 0 giants, 0 parity

0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort 4084 packets output, 1298712 bytes, 0 underruns

0 output errors, 0 applique, 0 interface resets

0 output buffer failures, 0 output buffers swapped out

0 carrier transitions

For Cisco 7100, Cisco 7200, and Cisco uBR7200 series routers, use the show controllers serial command, using arguments such as the slot and port number (slot/port), to display information that is specific to the serial interface hardware. Following is an example of the show controllers serial slot/port command that shows the serial port adapter installed on a Cisco 7200 series router in chassis slot 3:

router# show controllers serial 3/0

M1T-Serial: show controller:

PAS unit 0, subunit 0, f/w version 1-23, rev ID 0x1, version 2 idb = 0x608E3340, ds = 0x608E50C0, ssb=0x608E5A84

Clock mux=0x35, ucmd_ctrl=0x8, port_status=0x25 maxdgram=4474, bufpool=64Kb, 128 particles

TM=down CA=up LC=down line state: up

Serial DTE cable (Display text omitted.)

For a VIP2, use the show controllers serial command, using arguments such as those that specify the slot, port adapter, and port numbers (slot/port-adapter/port), to display information that is specific to the serial interface hardware. Following is an example of the show controllers serial slot/port adapter/interface command that shows serial port 2/0/1 on a one-port PA-E3 installed on a VIP2 in chassis slot 1:

router# show controllers serial 2/0/1 Serial2/0/1

Mx E3(2) HW Revision 0x2, FW Revision 2.42

Framing is g751, Clock Source is Line, Bandwidth limit is 34010. National Bit is 0, International Bits are: 0 0

DSU mode 0

Data in current interval (421 seconds elapsed):

0 Line Code Violations, 0 P-bit Coding Violation 0 C-bit Coding Violation

0 P-bit Err Secs, 0 P-bit Severely Err Secs

0 Severely Err Framing Secs, 0 Unavailable Secs

0 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Severely Errored Secs Total Data (last 1 15 minute intervals):

4 Line Code Violations, 0 P-bit Coding Violation, 0 C-bit Coding Violation,

0 P-bit Err Secs, 0 P-bit Severely Err Secs,

0 Severely Err Framing Secs, 0 Unavailable Secs,

3 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Severely Errored Secs No alarms detected.

(Display text omitted.)

8-14PA-E3 Serial Port Adapter Installation and Configuration

Image 60
Contents PA-E3 Serial Port Adapter Installation and Configuration Corporate HeadquartersPage Preface ObjectivesOrganization Section Title DescriptionRelated Documentation Related Documentation Section Title DescriptionRelated Documentation Cisco Connection Online Documentation CD-ROMCisco Connection Online Overview Port Adapter OverviewPort Adapter Overview One-Port PA-E3 Serial Port AdapterPA-E3 Serial Port Adapter Features PA-E3 Serial Port Adapter FeaturesManagement Information Base PA-E3 Port Adapter LEDsPA-E3 Receptacles and Cables PA-E3 Receptacles and CablesPA-E3 Port Adapter LEDs Name Color State DescriptionInteroperability Guidelines for PA-E3 DSUs 6PA-E3 Serial Port Adapter Installation and Configuration Preparing for Installation Parts and Tools RequiredSoftware and Hardware Requirements Software and Hardware RequirementsPA-2E3 Safety Guidelines Safety Guidelines4PA-E3 Serial Port Adapter Installation and Configuration Telephone Wiring Guidelines Electrical Equipment GuidelinesPreventing Electrostatic Discharge Damage Electrical Equipment GuidelinesCompliance Information Babt ComplianceITI-T Compliance TBR24 ComplianceVIP2 and the PA-E3 OverviewOverview Dimm U5PA-E3 in port adapter Slot PA-E3 in port adapter slot Removing a Port Adapter Removing a Port AdapterInstalling a Port Adapter Installing a Port AdapterAligning a Port Adapter in a Port Adapter Slot H3152 8PA-E3 Serial Port Adapter Installation and Configuration Catalyst RSM/VIP2 and the PA-E3 Port adapter securing screw Removing a Port Adapter Installing a Port Adapter Aligning a Port Adapter in a Port Adapter Slot 6PA-E3 Serial Port Adapter Installation and Configuration Cisco 7200 Series and the PA-E3 Cisco 7206 with a PA-E3 in Port Adapter SlotPort adapter Handle Lever unlocked Position Handling a Port Adapter Port adapter Handle Cisco uBR7200 Series and the PA-E3 Port adapters Port adapters Port adapter lever in unlocked position Inside slot guide PC board Metal carrier Port adapter retention clip in locked position 6PA-E3 Serial Port Adapter Installation and Configuration Installation Overview Cisco 7100 Series and the PA-E3Cisco 7140 Series Router-Port Adapter Slot 4 Location Installing a Port Adapter Guides Configuring the PA-E3 Interfaces Using the Exec Command InterpreterCisco 7200 Series and Cisco uBR7200 Series Ports Cisco 7200 Series and Cisco uBR7200 Series Ports Cisco 7206 Serial Port Number ExampleVIP2 Ports PA-E3 Interface Port Address Example- Cisco uBR7246 ShownCatalyst RSM/VIP2 Ports Catalyst RSM/VIP2 PortsRoute Switch Module Cisco 7100 Series PortsWith port adapters Performing a Basic Configuration Performing a Basic ConfigurationConfiguration Example Configuration ExampleCustomizing the PA-E3 Setting the Bandwidth Defining the DSU ModeSetting the Bandwidth Defining Set Bit NationalSetting the Cable Length Configuring Cyclic Redundancy ChecksConfiguring Cyclic Redundancy Checks Specifying E3 FramingUsing show Commands to Verify Status Checking the ConfigurationChecking the Configuration Checking the Configuration Step NumberRouter# show interfaces serial 2/0 14PA-E3 Serial Port Adapter Installation and Configuration Router# show controllers serial 0/1 Serial0/1 16PA-E3 Serial Port Adapter Installation and Configuration 73-1684-03 18PA-E3 Serial Port Adapter Installation and Configuration Using the ping Command to Verify Network Connection Using the ping Command to Verify Network ConnectionUsing the loopback Command to Verify the Physical Interface Using the loopback Command to Verify the Physical Interface 22PA-E3 Serial Port Adapter Installation and Configuration