Cisco Systems 7304 Routerconfig-if#mdl string eic fic, Generator lic pfi port unit string, 13-9

Page 9

Chapter 13 Configuring the 2-Port and 4-Port T3/E3 SPAs

 

 

 

Configuration Tasks

 

 

 

 

 

 

 

 

 

Command

Purpose

 

 

 

 

 

 

 

 

Router(config-if)#mdl [string {eic fic

Configures the Maintenance Data Link (MDL)

 

 

 

generator lic pfi port unit} string}]

message.

 

 

 

[transmit {idle-signal path test-signal}]

• eic string—Equipment identification code (up

 

 

 

 

 

 

 

 

to 10 characters), which is a value used to

 

 

 

 

describe a specific piece of equipment

 

 

 

 

according to ANSI T1.107-1995.

 

 

 

 

• fic string—Frame identification code (up to 10

 

 

 

 

characters), which is a value used to identify

 

 

 

 

where the equipment is located within a

 

 

 

 

building at a given location according to ANSI

 

 

 

 

T1.107-1995.

 

 

 

 

• generator string—Specifies the Generator

 

 

 

 

number string sent in the MDL Test Signal

 

 

 

 

message; can be up to 38 characters.

 

 

 

 

• lic string—Location identification code (up to

 

 

 

 

11 characters), which is a value used to

 

 

 

 

describe a specific location according to ANSI

 

 

 

 

T1.107-1995.

 

 

 

 

• pfi string—Specifies the Path Facility

 

 

 

 

Identification Code sent in the MDL Path

 

 

 

 

message; can be up to 38 characters.

 

 

 

 

• port string—Specifies the Port number string

 

 

 

 

sent in the MDL Idle Signal message; can be

 

 

 

 

up to 38 characters.

 

 

 

 

• unit string—Unit identification code (up to 6

 

 

 

 

characters), which is a value that identifies the

 

 

 

 

equipment location within a subslot according

 

 

 

 

to ANSI T1.107-1995.

 

 

 

 

• transmit idle-signal—Enables transmission

 

 

 

 

of the MDL idle signal message. An MDL idle

 

 

 

 

signal message, as defined by ANSI T1.107, is

 

 

 

 

distinguished from path and test signal

 

 

 

 

messages in that it contains a port number as

 

 

 

 

its final data element.

 

 

 

 

• transmit path—Enables transmission of the

 

 

 

 

MDL path message. An MDL path message,

 

 

 

 

as defined by ANSI T1.107, is distinguished

 

 

 

 

from idle and test signal messages in that it

 

 

 

 

contains a facility identification code as its

 

 

 

 

final data element.

 

 

 

 

• transmit test-signal—Enables transmission

 

 

 

 

of the MDL test signal message. An MDL test

 

 

 

 

signal message, as defined by ANSI T1.107, is

 

 

 

 

distinguished from path and idle signal

 

 

 

 

messages in that it contains a generator

 

 

 

 

number as its final data element.

 

 

 

 

 

 

 

 

 

 

 

Cisco 7304 Router Modular Services Card and Shared Port Adapter Software Configuration Guide

 

 

 

 

 

 

 

 

OL-4807-02

 

 

13-9

 

 

 

 

 

 

Image 9
Contents 13-1 A P T E RSetting the Card Type Required Configuration TasksRouter# configure terminal 13-2Verifying Controller Configuration Configure the InterfaceInternal line 13-3Verifying Interface Configuration 13-4Router# show controllers serial 6/0/2 brief Routerconfig# interface serial 3/0/0 Optional ConfigurationsSpecifying the Interface Address on a SPA 13-513-6 Configuring Data Service Unit Mode13-7 Verifying DSU ModeConfiguring Maintenance Data Link Routerconfig# interface serial slot/subslot/port13-8 Transmit idle-signal path test-signal Routerconfig-if#mdl string eic ficGenerator lic pfi port unit string 13-9Configuring Scramble Verifying MDL13-10 Verifying Scramble Configuration Scrambling is enabled13-11 Verifying Framing Configuration Configuring FramingM13 G832Routerconfig-if# encapsulation hdlc ppp Configuring EncapsulationVerifying Encapsulation Frame-relayVerify Cable Length Setting Configuring Cable Length13-14 Router# show interfaces serial 4/0/0 Serial4/0/0Configuring the Trace Trail Buffer Configuring Invert DataVerify Invert Data Setting 13-15Routerconfig-if# ttb country rnode serial Verify TTB SettingsSnode soperator x string 13-16Saving the Configuration Verifying Per-Port Interface Status13-17 Monitoring Per-Port Interface Statistics 13-18Show controller serial 5/0/2 Serial5/0/2 DSU Configuration Example MDL Configuration Example13-19 Framing Configuration Example Scrambling Configuration ExampleEncapsulation Configuration Example Cable Length Configuration ExampleInvert Data Configuration Example Trace Trail Buffer Configuration Example13-21 13-22
Related manuals