Baracoda Real Time mode, No Data Loss mode Enable ACK beep, No Data Loss mode Disable ACK beep

Page 11

Data Capture for Workforce in Motion

1.4.1.Real Time mode

Erases all captured data stored in memory and forces the scanner in Real time mode. No other setting is changed.

Important reminder: if an ACK beep or buffer is needed, the scanner must be set in the “no data loss mode” first.

Enable Real Time with « No Data Loss »

mode

Enable Real Time without « No Data

Loss » mode

1.4.2.No Data Loss mode - Enable “ACK” beep

Forces the scanner in Real Time mode (with data acknowledgement); Erases all captured data stored in memory. The scanner should have been previously set in the “No data loss mode” ON (So scan the “Enable Real Time with No Data Loss mode” barcode before).

Enable ACK beep

1.4.3.No Data Loss mode - Disable “ACK” beep

Forces the scanner in Real Time mode (without data acknowledgement); Erases all captured data stored in memory. The scanner should have been previously set in the “No data loss mode” ON (So scan the “Enable Real Time with No Data Loss mode” barcode before).

Disable ACK beep

1.4.4.Real Time - Buffered data option

It’s possible to set the scanner in “Real Time with No Data Loss mode” but with no bufferisation (buffer configured to 0) when it’s not connected. In this particular situation the trigger will not activate the beam: so impossible to read barcodes in this mode, and Both LEDs blinks orange.

Max Buffered Barcodes = 0

RoadRunners Evolution –L (1D) & -LA (Laser) – Programming Guide v1.3

- 11 -

Image 11
Contents RoadRunners Evolution -L 1D & -LA Laser Programming Guide Summary Appendix 1 Ascii Table A-Z, A-Z, 0-9, PUNCTUATION, Control Revision History Introduction General default settings General ConfigurationTurn scanner OFF Baracoda advanced featuresSwitch on delay Shutdown timersNo data loss mode and Baracoda Header Reading ModeAutoscan Real Time mode Operating ModeReal Time Buffered data option Real Time modeNo Data Loss mode Enable ACK beep No Data Loss mode Disable ACK beepBatch Mode Batch modeDifferent connection methods LED OFF Buzzer and Led SettingsBluetooth name Bluetooth settingsSniff period settings RF Power emission settings Security code PIN settingsTimestamp option Data formatYES Data Prefix/Suffix Barcode Prefix/Suffix AIM Symbology Identifier Set decoder barcode length Decoder default settingsEnable/Disable All Symbologies Voting Min/Max length per symbology Enable/Disable Codabar Codabar settingsSymbology table Set Lengths for Codabar Codabar Start/Stop charactersCodabar Check Digit Verification AIM recommendation Transmit Code 11 check digits Code 11 SettingsEnable/Disable Code Code 11 check digits verificationCode 39 Start/stop characters Code 39 settingsEnable/Disable Code 39 Full Ascii Set lengths for Code Accepted Code 39 charactersCode 39 Check Digit Verification Italian PharmaCode settings Code 93 SettingsSet lengths for Code 128/EAN Code 128 SettingsEnable/Disable Code 128/EAN EAN 128 Group Separator Interleaved 2of 5 Check Digit Interleaved 2 of 5 SettingsEnable/Disable AIM ID Transmission Enable/Disable Interleaved 2MSI Check Digit MSI Code SettingsEnable/Disable MSI Set lengths for Interleaved 2Standard 2 of 5 Check Digit Standard 2 of 5 SettingsEnable/Disable Standard 2 Set lengths for MSISet lengths for Standard 2 UPC/ EAN SettingsEnable/Disable UPC/EAN Transmit UPC-A Check Digit Transmit EAN13 Check DigitTransmit UPC-E Check Digit Transmit EAN 8 Check DigitUPC-A, UPC-E, EAN conversions Transmit UPC number system for UPC-EAdd-on digits settings ISSN/ISBN settings15.3. GS1 DataBar 14 Linkage flag Transmission 15. GS1 DataBar RSS 14 SettingsEnable/Disable GS1 DataBar 15.2. GS1 DataBar 14 Check Digit Transmission16.3. GS1 DataBar Limited Linkage flag Transmission 16. GS1 DataBar RSS Limited SettingsEnable/Disable GS1 DataBar Limited 16.2. GS1 DataBar Limited Check Digit TransmissionCapital letters A-Z Small letters a-z Ponctuation Decimal numbers Control Characters Appendix 2 AIM symbology identifiers structure