The SI prefix is a two (2) or three (3) character string: ] c m where

] : SI indicator

c : Symbology Identification

m : Modifier characters (optional)

Symbology Character

A

Code 39

B

Telepen

C

Code 128

D

Code One

E

EAN/UPC

F

Codabar

G

Code 93

H

Code 11

I

ITF 25

K

Code 16K

L

PDF417

M

MSI code

N

Anker Code

O

Codablock

P

Plessey Code

R

Straight 2 of 5 (two bar start/stop codes)

S

Straight 2 of 5 (three bar start/stop codes)

T

Code 49

X

Other Bar code

Z

Non Barcode data

Modifier Characters

The modifier character is determined by summing the option values of each symbology. If the sum is greater than 9, use A, B, C, D, E, F in the place of 10, 11, 12, 13, 14 and 15.

Code 39 Option Values

0No check character or Full ASCII

1Reader has performed mod 43 check

2Reader has performed mod 43 check and stripped the check character

4 Reader has performed Full ASCII conversion

Telepen Option Values

0Full ASCII mode

1Double density numeric mode

2Double density numeric followed by full ASCII

4Full ASCII followed by double density numeric

Code 128 Option Values

0Standard

1Function code 1 in first character position

2Function code 2 in second character position

4Concatenation according to ISBT specification has been performed, and concatenated data follows.

RoadRunners Evolution –L (1D) & -LA (Laser) – Programming Guide v1.3

- 48 -

Image 48
Contents RoadRunners Evolution -L 1D & -LA Laser Programming Guide Summary Appendix 1 Ascii Table A-Z, A-Z, 0-9, PUNCTUATION, Control Revision History Introduction General Configuration General default settingsBaracoda advanced features Switch on delayShutdown timers Turn scanner OFFReading Mode No data loss mode and Baracoda HeaderAutoscan Operating Mode Real Time modeReal Time mode No Data Loss mode Enable ACK beepNo Data Loss mode Disable ACK beep Real Time Buffered data optionBatch mode Batch ModeDifferent connection methods Buzzer and Led Settings LED OFFBluetooth settings Bluetooth nameSniff period settings Security code PIN settings RF Power emission settingsData format Timestamp optionYES Data Prefix/Suffix Barcode Prefix/Suffix AIM Symbology Identifier Decoder default settings Enable/Disable All SymbologiesSet decoder barcode length Voting Min/Max length per symbology Codabar settings Symbology tableEnable/Disable Codabar Codabar Start/Stop characters Codabar Check Digit Verification AIM recommendationSet Lengths for Codabar Code 11 Settings Enable/Disable CodeCode 11 check digits verification Transmit Code 11 check digitsCode 39 settings Enable/Disable Code 39 Full AsciiCode 39 Start/stop characters Accepted Code 39 characters Code 39 Check Digit VerificationSet lengths for Code Code 93 Settings Italian PharmaCode settingsCode 128 Settings Enable/Disable Code 128/EANSet lengths for Code 128/EAN EAN 128 Group Separator Interleaved 2 of 5 Settings Enable/Disable AIM ID TransmissionEnable/Disable Interleaved 2 Interleaved 2of 5 Check DigitMSI Code Settings Enable/Disable MSISet lengths for Interleaved 2 MSI Check DigitStandard 2 of 5 Settings Enable/Disable Standard 2Set lengths for MSI Standard 2 of 5 Check DigitUPC/ EAN Settings Enable/Disable UPC/EANSet lengths for Standard 2 Transmit EAN13 Check Digit Transmit UPC-E Check DigitTransmit EAN 8 Check Digit Transmit UPC-A Check DigitTransmit UPC number system for UPC-E UPC-A, UPC-E, EAN conversionsISSN/ISBN settings Add-on digits settings15. GS1 DataBar RSS 14 Settings Enable/Disable GS1 DataBar15.2. GS1 DataBar 14 Check Digit Transmission 15.3. GS1 DataBar 14 Linkage flag Transmission16. GS1 DataBar RSS Limited Settings Enable/Disable GS1 DataBar Limited16.2. GS1 DataBar Limited Check Digit Transmission 16.3. GS1 DataBar Limited Linkage flag TransmissionCapital letters A-Z Small letters a-z Ponctuation Decimal numbers Control Characters Appendix 2 AIM symbology identifiers structure