Baracoda LA manual Autoscan

Page 9

Data Capture for Workforce in Motion

In Autoscan mode, the scan beam is continuously on. This mode enables to scan continuously.

Autoscan

In Smart Autoscan mode, for a battery power consumption optimisation issue, the scanner will be continuously flashing.

Smart Autoscan

The “No duplicate scan” option has been developed for users who do not want to scan the same barcode twice.

«no duplicate scans » disabled (*)

«no duplicate scans » enabled + error signal

￿If the same barcode is scanned, an error signal is played (two beeps (lower tone) and a red enlightening of the led)

«no duplicate scans » enabled + no decoding

￿If the same barcode is trying to be scanned, it won’t be. The laser beam will still be enlightening.

RoadRunners Evolution –L (1D) & -LA (Laser) – Programming Guide v1.3

- 9 -

Image 9
Contents RoadRunners Evolution -L 1D & -LA Laser Programming Guide Summary Appendix 1 Ascii Table A-Z, A-Z, 0-9, PUNCTUATION, Control Revision History Introduction General default settings General ConfigurationSwitch on delay Baracoda advanced featuresShutdown timers Turn scanner OFFNo data loss mode and Baracoda Header Reading ModeAutoscan Real Time mode Operating ModeNo Data Loss mode Enable ACK beep Real Time modeNo Data Loss mode Disable ACK beep Real Time Buffered data optionBatch Mode Batch modeDifferent connection methods LED OFF Buzzer and Led SettingsBluetooth name Bluetooth settingsSniff period settings RF Power emission settings Security code PIN settingsTimestamp option Data formatYES Data Prefix/Suffix Barcode Prefix/Suffix AIM Symbology Identifier Decoder default settings Enable/Disable All SymbologiesSet decoder barcode length Voting Min/Max length per symbology Codabar settings Symbology tableEnable/Disable Codabar Codabar Start/Stop characters Codabar Check Digit Verification AIM recommendationSet Lengths for Codabar Enable/Disable Code Code 11 SettingsCode 11 check digits verification Transmit Code 11 check digitsCode 39 settings Enable/Disable Code 39 Full AsciiCode 39 Start/stop characters Accepted Code 39 characters Code 39 Check Digit VerificationSet lengths for Code Italian PharmaCode settings Code 93 SettingsCode 128 Settings Enable/Disable Code 128/EANSet lengths for Code 128/EAN EAN 128 Group Separator Enable/Disable AIM ID Transmission Interleaved 2 of 5 SettingsEnable/Disable Interleaved 2 Interleaved 2of 5 Check DigitEnable/Disable MSI MSI Code SettingsSet lengths for Interleaved 2 MSI Check DigitEnable/Disable Standard 2 Standard 2 of 5 SettingsSet lengths for MSI Standard 2 of 5 Check DigitUPC/ EAN Settings Enable/Disable UPC/EANSet lengths for Standard 2 Transmit UPC-E Check Digit Transmit EAN13 Check DigitTransmit EAN 8 Check Digit Transmit UPC-A Check DigitUPC-A, UPC-E, EAN conversions Transmit UPC number system for UPC-EAdd-on digits settings ISSN/ISBN settingsEnable/Disable GS1 DataBar 15. GS1 DataBar RSS 14 Settings15.2. GS1 DataBar 14 Check Digit Transmission 15.3. GS1 DataBar 14 Linkage flag TransmissionEnable/Disable GS1 DataBar Limited 16. GS1 DataBar RSS Limited Settings16.2. GS1 DataBar Limited Check Digit Transmission 16.3. GS1 DataBar Limited Linkage flag TransmissionCapital letters A-Z Small letters a-z Ponctuation Decimal numbers Control Characters Appendix 2 AIM symbology identifiers structure