Baracoda RoadRunners BRR-L & BRR-LA Programming guide Nov, 2.3.2/ Shutdown timers, 5/29

Page 5
2.3.2/ Shutdown timers

RoadRunners BRR-L & BRR-LA Programming guide Nov 2007

2.3.2/ Shutdown timers

There are two differents ‘shutdown timers’ :

-when connected timer : delay between the last scanned barcode and the switch off when the scanner is connected to a host

-Not connected timer : delay between the last scanned barcode and the switch off when the scanner is not connected to any host

It is possible to set those timers to ‘infinite’. In that case, the scanner will stay all the time ON.

Set shutdown timers to infinity

By default, timers value are :

when connected timer = 20 minutes Not connected timer = 10 minutes

Set shutdown timers to defaults

2.3.3/ No data loss mode and Baracoda Header

Baracoda header:

It is a proprietary data encapsulation. It is necessary to activate it to use the Baracoda keyboard emulation (Kemul) and Hyper terminal.

The Baracoda header is enabled in default settings

No data loss mode:

Baracoda has developed a proprietary communication protocol in order to enhance the security of the Bluetooth transmission.

Every barcode sent to the host must be acknowledged by the host (until then, the scanner will transmit it again and again).

This acknowledgment is disabled in default settings. It is strongly recommended to set this protocol acknowledgment on when using the scanner with the BaracodaManager.

Enable Baracoda header + “No Data loss mode” ON

Disable Baracoda header + “No data loss mode” OFF

Enable Baracoda header

+ “No Data loss mode” OFF (*)

© Baracoda 2007

5/29

Image 5
Contents Data Capture for RoadRunners BRR-L & BBR-LA Programming GuideWorkforce in Motion Important notice2/ GENERAL CONFIGURATION RoadRunners BRR-L & BRR-LA Programming guide Nov3/ DECODER SETTINGS RoadRunners BRR-L & BRR-LA Programming Guide3/29 1/ Introduction2.1/ Reset all parameters 2/ General Configuration2.3/ Baracoda advanced features 2.2/ Erase all barcodes in memory2.3.3/ No data loss mode and Baracoda Header Baracoda header 2.3.2/ Shutdown timersNo data loss mode 5/296/29 Programming procedure for “set Timestamp” option2.3.4/ Timestamp Option 7/29 2.4/ Reading Mode2.5.1/ Real time mode 2.5/ Operating ModeREAL TIME mode REAL TIME with ACK beep and bufferisation9/29 2.5.2/ Batch mode2.6/ Cradle / RS232 jack 2.6.1/ Cradle 2.7/ Buzzer and Led Settings2.6.2/ RS232 jack Parameters are11/29 2.8/ Bluetooth commands 2.8.1/ Bluetooth name2.8.3/ Power emission settings 2.8.2/ Sniff settings2.8.4/ Security code PIN settings 12/292.9.1/ Prefix/suffix 2.9/ Prefix and suffixRoadRunners BRR-L Programming guide 13/2914/29 2.9.2/ Postrefix/postsuffixFeature enabled for CPU firmware version ≥ 3.1/ Symbology default settings 3/ Decoder settings3.2/ Symbology Identifier 3.4/ Disable All Symbologies3.5/ Set decoder barcode length 3.6/ Codabar settingsRoadRunners BRR-L Programming guide Programming procedure for “set barcode length” option17/29 3.7/ Code 11 Settings3.8/ Code 39 settings Code 39 - format - full ASCII 3.9/ Code 93 SettingsCode 39 - check digit - not used 18/2919/29 3.10/ Code 128 Settings 3.10.1/ General3.10.2/ EAN 128 Group Separator 20/29 3.11/ Interleaved 2 of 5 Settings3.12/ MSI Code Settings 21/29 3.13/ Standard 2 of 5 Settings3.14/ UPC/ EAN Settings 22/29 23/29 3.15/ Set min or Max length optionProgramming procedure for “set min Max length” option Interleaved 2 of Standard 2 of 5 industrial 2 of Code MSI UPC E EAN SELECT ALL Code Code 128 / EAN EAN 13 / UPC A Code CodabarSymbology table Selected SymbologyCapital letters A-Z APPENDIX 1 ASCII Table A-Z, a-z, 0-9, ponctuation, Control characters25/29 NameSmall letters a-z Ponctuation Space26/29 a b c d e f g h i j k l m27/29 Decimal numbers28/29 Control CharactersCR EOT ETX LF NUL SOH STX TABSymbology Character APPENDIXModifier Characters Code 39 Option Values