Page 23
RoadRunners BRR-L Programming guide | dec 2006 |
3.15/ Set min or Max length option
The following is a procedure to follow for every barcodes
START
Read « Start - Set min (Max) length » label
Read intermediary label from the below table to select the desired symbology to configure
Read intermediary label
Corresponding to the next digit of the min (Max) length value to
apply (as on a calculator).
NO
Finished ?
YES
Read « END of config » label
END
Programming procedure for “set min (Max) length” option.
Contents
Important notice
RoadRunners BRR-L & BBR-LA Programming Guide
Data Capture for
Workforce in Motion
RoadRunners BRR-L & BRR-LA Programming Guide
RoadRunners BRR-L & BRR-LA Programming guide Nov
2/ GENERAL CONFIGURATION
3/ DECODER SETTINGS
3/29
1/ Introduction
2.2/ Erase all barcodes in memory
2/ General Configuration
2.1/ Reset all parameters
2.3/ Baracoda advanced features
5/29
2.3.2/ Shutdown timers
2.3.3/ No data loss mode and Baracoda Header Baracoda header
No data loss mode
6/29
Programming procedure for “set Timestamp” option
2.3.4/ Timestamp Option
7/29
2.4/ Reading Mode
REAL TIME with ACK beep and bufferisation
2.5/ Operating Mode
2.5.1/ Real time mode
REAL TIME mode
9/29
2.5.2/ Batch mode
Parameters are
2.7/ Buzzer and Led Settings
2.6/ Cradle / RS232 jack 2.6.1/ Cradle
2.6.2/ RS232 jack
11/29
2.8/ Bluetooth commands 2.8.1/ Bluetooth name
12/29
2.8.2/ Sniff settings
2.8.3/ Power emission settings
2.8.4/ Security code PIN settings
13/29
2.9/ Prefix and suffix
2.9.1/ Prefix/suffix
RoadRunners BRR-L Programming guide
14/29
2.9.2/ Postrefix/postsuffix
Feature enabled for CPU firmware version ≥
3.4/ Disable All Symbologies
3/ Decoder settings
3.1/ Symbology default settings
3.2/ Symbology Identifier
Programming procedure for “set barcode length” option
3.6/ Codabar settings
3.5/ Set decoder barcode length
RoadRunners BRR-L Programming guide
17/29
3.7/ Code 11 Settings
3.8/ Code 39 settings
18/29
3.9/ Code 93 Settings
Code 39 - format - full ASCII
Code 39 - check digit - not used
19/29
3.10/ Code 128 Settings 3.10.1/ General
3.10.2/ EAN 128 Group Separator
20/29
3.11/ Interleaved 2 of 5 Settings
3.12/ MSI Code Settings
21/29
3.13/ Standard 2 of 5 Settings
3.14/ UPC/ EAN Settings
22/29
23/29
3.15/ Set min or Max length option
Programming procedure for “set min Max length” option
Selected Symbology
SELECT ALL Code Code 128 / EAN EAN 13 / UPC A Code Codabar
Interleaved 2 of Standard 2 of 5 industrial 2 of Code MSI UPC E EAN
Symbology table
Name
APPENDIX 1 ASCII Table A-Z, a-z, 0-9, ponctuation, Control characters
Capital letters A-Z
25/29
a b c d e f g h i j k l m
Ponctuation Space
Small letters a-z
26/29
27/29
Decimal numbers
NUL SOH STX TAB
Control Characters
28/29
CR EOT ETX LF
Code 39 Option Values
APPENDIX
Symbology Character
Modifier Characters