Emulex EMULEX manual Parmget label, Gets the value of a specified parameter in the driver

Page 23

dynamic: no

desc: Select Fibre Channel topology

-----------------------------------------------------------------

label: link-speed min: 0

current: 0 max: 4 default: 0 dynamic: no

desc: Select link speed

-----------------------------------------------------------------

label: num-nodes min: 2

current: 512 max: 512 default: 512 dynamic: no

desc: Number of fibre channel nodes (NPorts) the driver will support.

-----------------------------------------------------------------

label: cr-delay min: 0

current: 0 max: 63 default: 0 dynamic: no

desc: A count of milliseconds after which an interrupt response is generated

-----------------------------------------------------------------

label: cr-count min: 1

current: 1 max: 255

default: 1

dynamic: no

desc: A count of I/O completions after which an interrupt response is generated

-----------------------------------------------------------------

label: assign-alpa min: 0x0

current: 0x0 max: 0xef

default: 0x0

dynamic: no

desc: Assigns a preferred ALPA to the port. Only used in Loop topology.

-----------------------------------------------------------------

label: adisc-support min: 0

current: 1 max: 2 default: 1

dynamic: yes

desc: Sets the Fibre Channel ADISC login support level.

-----------------------------------------------------------------

label: pm-support min: 0

current: 1 max: 1 default: 1 dynamic: no

desc: Enables power management support.

parm_get <label>

Gets the value of a specified parameter in the driver.

FCA Utilities Reference Manual

Page 19

Image 23
Contents FCA Utilities FCA Utilities Reference Manual Introduction Hba Using the emlxdrv UtilitySolaris Fibre Channel Stack Fibre Channel OverviewSolaris Software Stack Enter y. The following message is displayed Installing the UtilitiesRemoving the Utilities Using the emlxuremove Script To remove the emlxu utilities package, do the following Installing the Utilities Package ManuallyRemoving the Utilities Package Manually Updating the Utilities Package Manually Update the emlxu utilities by doing the followingModes of Operation emlxadm Interactive Mode emlxadmCLI Mode emlxadm Command Descriptions emlxadmGetlogiparams wwpn GetnumdevsGetdevlist FCA Utilities Reference Manual Getsymnname GethostparamsGetsympname Setsympname stringDevremove wwpn Devlogin wwpnDevlogout Getstate wwpnDownloadfw filename GetbootrevDownloadfcode filename GetfwrevForcedump Downloadboot filenameDownloads the specified boot image file to the HBA Example GetdumpsizeGettopology Resetlink wwpn or zero for local linkResethard ResethardcoreType PID Parmgetlist Returns the total number of configurable parameters ExampleReturns a list of configurable parameters Example ParmgetnumFCA Utilities Reference Manual Gets the value of a specified parameter in the driver Parmget labelExample This example attempts to set a static parameter Parmset label valueMsgbuf all or number -i interval Displays all of the current host HBA API attributes Example GethostattrsGetportattrs index, wwn or all Seagate ST39103FC = Seagate ST39103FC Exits the utility program Example Displays a help menu of utility commands ExampleGetpath index Hba Repeats the last command ExampleEmlxdrv utility program can be run in two modes Interactive Interactive Mode emlxdrvModes of Operation emlxdrv CLI Mode emlxdrv Setemlxsall Command Descriptions emlxdrvSetemlxs alias SetemlxssunCleardev alias Setlpfc aliasSetlpfcnonsun Clearnonsun ClearlpfcClearemlxs ClearsunClearall Emlxdrv q Exiting