Dynex Comprehensive Guide to UPS Systems

Page 2

Dynex-DX-800U UPS.fm Page 2 Tuesday, July 26, 2005 6:07 PM

2

Introduction

Dynex DX-800 UPS/Battery

Backup System

Introduction

The DX-800 UPS/Battery Backup System provides protection from power surges and power failure. The UPS uses an automatic voltage regulator to regulate the electricity coming into your computer to make sure that your computer receives a steady and consistent power flow. In the case of power failure, the UPS provides battery power to your computer so you can save your work and shut down your computer. The UPS includes software that will save all your open files and shut down your computer.

Package contents

Inspect the UPS upon receipt. The box should contain the following:

UPS

User’s manual

PowerPanel™ Personal Edition software CD

USB cable

Telephone cable

Warranty registration card

Coaxial Cable

Identifying components

Contents

 

Important safety instructions

........................................................... 2

Package contents

2

Installing your UPS

3

Status indicators

3

Troubleshooting

5

Specifications

5

Legal notices

5

Français

6

Español

10

5

6 6

11

8

7

8

3 4

2 2

9

9

1

1

10

Important safety instructions

Save these instructions.

This manual contains important safety instructions. Read and follow all instructions carefully during installation and operation of your UPS. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.

Warnings:

This UPS is not intended for use with medical or life support equipment. Do not use in any circumstance that would affect the operation or safety of any life support equipment or with any medical applications or patient care.

Do not use with or near aquariums. Condensation from the aquarium can cause your UPS to short out and cause a fire or electrical shock.

To avoid electrical shock, turn off your UPS and unplug it from the AC power source before replacing the battery or installing a computer component.

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled, indoor area, free of conductive contaminants. (See Specifications for acceptable temperature and humidity range).

To reduce the risk of electric shock, do not remove the cover except to replace the battery. No user serviceable parts inside except for the battery.

Even if your UPS is not plugged into an electrical outlet, electrical energy may still flow through your UPS from the battery.

Your UPS must be connected to an AC power outlet that has fuse or circuit breaker protection. Do not plug into an ungrounded outlet. If you need to de-energize your UPS, turn it off and unplug it.

 

Component

Description

 

 

 

 

 

 

 

 

1

Battery-powered and

Plug devices into these outlets that need

 

 

 

surge-protected

battery-backup power, for example, a

 

 

 

outlets

computer, monitor, or external storage

 

 

 

 

device. These outlets provide both surge

 

 

 

 

protection and battery-backup power. If a

 

 

 

 

power failure occurs, these outlets supply

 

 

 

 

power to devices.

 

 

 

 

 

 

 

 

2

Surge-protected

Plug devices into these outlets that do not

 

 

 

outlets

need battery-backup power, for example,

 

 

 

 

printers and speakers.

 

 

 

 

 

 

 

 

3

Power switch

Press to turn your UPS on and off.

 

 

 

 

 

 

 

 

4

Power indicator

Lights when your UPS is turned on.

 

 

 

 

 

 

 

 

5

Electrical wiring fault

Lights when your UPS detects an electrical

 

 

 

indicator

wiring problem, such as a bad ground, a

 

 

 

 

missing ground, or reverse wiring. If this

 

 

 

 

indicator lights, unplug your UPS and contact

 

 

 

 

an electrician to repair the outlet.

 

 

 

 

Caution: If a wiring problem exists, your UPS

 

 

 

 

cannot provide surge protection.

 

 

 

 

 

 

 

 

6

Communication jacks

Plug your dial-up modem, fax machine, or

 

 

 

 

telephone into the IN communication jack,

 

 

 

 

then plug the telephone cable into the OUT

 

 

 

 

communication jack and your telephone

 

 

 

 

outlet.

 

 

 

 

 

 

 

 

7

Circuit breaker

Provides overload and fault protection for

 

 

 

 

your UPS.

 

 

 

 

 

 

 

 

8

Serial and USB ports

Connect your computer to one of these ports

 

 

 

 

to monitor the status of your UPS. You need

 

 

 

 

to install the PowerPanel Personal Edition

 

 

 

 

software to monitor your UPS.

 

 

 

 

 

 

 

 

9

AC adapter outlets

Plug AC adapters into these outlets.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 2
Contents DX-800U Important safety instructions Package contentsContents IntroductionInstalling PowerPanel Personal Edition software Installing your UPSStatus indicators Installing your UPSTo replace the battery Replacing the batteryStatus indicators Turn off and unplug all connected devicesTroubleshooting TroubleshootingSpecifications Legal noticesInstructions de sécurité Importantes Contenu de l’emballageTable des matières Identification des composantsMontage de l’onduleur sur un mur Installation de l’onduleurInstallation de l’onduleur Témoins détat Installation du logiciel PowerPanel Personal EditionRemplacement de la batterie Témoins détatDépannage Problème Cause probable SolutionDépannage Introducción CaractéristiquesAvis juridiques ContenidoIdentificación de componentes Contenido de la cajaInstalación de su UPS Contenido de la cajaMontaje de su UPS en una pared Instalación del software PowerPanel Personal EditionIndicadores de estado Indicadores de estadoUse guantes y botas de caucho Reemplazo de la bateríaSolo utilice herramientas con agarraderas aisladas Apagar y desconectar los dispositivos conectadosAvisos legales Solución de problemasEspecificaciones Número de asistencia 800Dynex-DX-800U UPS.fm Page 15 Tuesday, July 26, 2005 607 PM