Dynex DX-800U Replacing the battery, Status indicators, Turn off and unplug all connected devices

Page 4

Dynex-DX-800U UPS.fm Page 4 Tuesday, July 26, 2005 6:07 PM

4

Power

Wiring

Audible

 

On

Fault

Alarm

Condition

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

Off

Long

System Overload–The amount

 

 

 

 

beep

of power required by plugged

 

 

 

 

 

in devices exceeds the amount

 

 

 

 

 

of power your UPS can supply.

 

 

 

 

 

Turn off your UPS, unplug at

 

 

 

 

 

least one device, wait 10

 

 

 

 

 

seconds, reset the circuit

 

 

 

 

 

breaker, then turn on your UPS.

 

 

 

 

Off

On/Off

Long

Battery Overload–The amount

 

 

 

 

beep

of power required by devices

 

 

 

 

 

plugged into the

 

 

 

 

 

battery-powered outlets

 

 

 

 

 

exceeds the amount of power

 

 

 

 

 

the battery can supply. Turn the

 

 

 

 

 

UPS off, unplug at least one

 

 

 

 

 

device from battery-powered

 

 

 

 

 

outlets, wait 10 seconds, reset

 

 

 

 

 

the circuit breaker, then turn on

 

 

 

 

 

your UPS.

 

 

 

 

On/Off

On

None

Electrical Wiring Fault–The AC

 

 

 

 

 

outlet your UPS is plugged into

 

 

 

 

 

has a wiring problem, such as a

 

 

 

 

 

bad ground, a missing ground,

 

 

 

 

 

or reversed wiring. Contact an

 

 

 

 

 

electrician to repair the outlet or

 

 

 

 

 

use a different outlet.

 

 

 

 

 

 

Replacing the battery

Warnings:

Read and follow the Important Safety Instructions before servicing the battery. Service the battery under the supervision of personnel knowledgeable of batteries and their precautions.

Use only the specified type of battery. See your dealer for replacement batteries.

The battery may present a risk of electrical shock. Do not dispose of battery in a fire because it may explode. Follow all local ordinances regarding correct disposal of batteries. Almost any retailer that sells lead-acid batteries collects used batteries for recycling, as required by most state laws.

Do not open or damage the batteries. The batteries contain electrolytes that are harmful to skin and eyes.

A battery can present a high risk of short circuit current and electrical shock. Take the following precautions before replacing the battery:

Remove all watches, rings, or other metal objects.

Only use tools with insulated handles.

Do not lay tools or metal parts on top of the battery or any terminals.

Wear rubber gloves and boots.

Determine if the battery is inadvertently grounded. If grounded, remove the source of ground. Contact with a grounded battery can result in electrical shock.

To replace the battery:

1Turn off and unplug all connected devices.

2Turn the UPS off and unplug it from the AC power source.

3 Turn the UPS upside down.

Status indicators

4Remove the retaining screw.

5Slide the battery compartment cover completely off of your UPS.

6 Remove the battery from the compartment.

7Disconnect the battery wires from the battery. Note which wire is connected to the positive (+) and negative (–) terminals of the battery.

8Install the replacement battery by connecting the red wire and black wire to the positive (+) and negative (–) terminal of the battery.

9Put the battery back into the compartment.

10Slide back the battery compartment cover and tighten the retaining screw.

11Recharge your UPS for 4 - 8 hours to fully charge the battery.

Warning: Batteries are consider hazardous waste and must be disposed of correctly. Almost any retailer that sells lead-acid batteries collects used batteries for recycling, as required by most state laws.

Image 4
Contents DX-800U Package contents ContentsImportant safety instructions IntroductionInstalling your UPS Status indicatorsInstalling PowerPanel Personal Edition software Installing your UPSReplacing the battery Status indicatorsTo replace the battery Turn off and unplug all connected devicesTroubleshooting SpecificationsTroubleshooting Legal noticesContenu de l’emballage Table des matièresInstructions de sécurité Importantes Identification des composantsInstallation de l’onduleur Installation de l’onduleurMontage de l’onduleur sur un mur Installation du logiciel PowerPanel Personal Edition Remplacement de la batterieTémoins détat Témoins détatDépannage Problème Cause probable SolutionDépannage Caractéristiques Avis juridiquesIntroducción ContenidoContenido de la caja Instalación de su UPSIdentificación de componentes Contenido de la cajaInstalación del software PowerPanel Personal Edition Indicadores de estadoMontaje de su UPS en una pared Indicadores de estadoReemplazo de la batería Solo utilice herramientas con agarraderas aisladasUse guantes y botas de caucho Apagar y desconectar los dispositivos conectadosSolución de problemas EspecificacionesAvisos legales Número de asistencia 800Dynex-DX-800U UPS.fm Page 15 Tuesday, July 26, 2005 607 PM