Troubleshooting | 5 |
Troubleshooting
Problem | Probable cause | Solution |
|
|
|
The | The circuit breaker | Turn off your UPS |
outlets stop | has tripped due to an | and unplug at least |
providing power to | overload. | one device. Wait 10 |
devices. The circuit |
| seconds, reset the |
breaker button is |
| circuit breaker by |
projecting from the |
| depressing the |
side of your UPS. |
| button, then turn on |
|
| your UPS. |
|
|
|
The battery does not | The battery charge is | Recharge the battery. |
run as long as | depleted. |
|
expected. | The battery is worn | Replace the battery. |
| ||
| out. |
|
|
|
|
The UPS will not turn | The UPS is not | Plug the UPS into an |
on. | plugged in. | electrical outlet. |
| The on/off switch is | Turn off your UPS. |
| designed to prevent | Wait 10 seconds, |
| damage by rapidly | then turn on your |
| turning it off and on. | UPS. |
| Mechanical problem | Contact your |
|
| supplier. |
|
|
|
PowerPanel™ | The USB or serial | Connect the USB or |
Personal Edition | cable is not | serial cable to your |
software is inactive | connected. | UPS unit and an open |
(all icons are gray). |
| USB or serial port on |
|
| the back of the |
|
| computer. You must |
|
| use the cable that |
|
| came with your UPS. |
| The USB or serial | Check the back of the |
| cable is connected to | computer for an |
| the wrong port. | additional USB or |
|
| serial port. Move the |
|
| cable to this port. |
| Your UPS is not | Shut down your |
| providing battery | computer and turn |
| power. | off your UPS. Wait 10 |
|
| seconds, turn on |
|
| your UPS. This should |
|
| reset your UPS. |
| The serial cable is not | Use the serial cable |
| the cable that was | that came with your |
| included with your | UPS. |
| UPS. |
|
|
|
|
Specifications
Capacity | 800 VA /450 W |
|
|
Input voltage on utility | 90 V to 140 V |
|
|
Input frequency | 57 Hz to 63 Hz |
|
|
120 VAC ± 5 % | |
|
|
Transfer time | 6 ms typical |
|
|
Max. load for UPS outlets | 800 VA /450 W |
(4 Outlets) |
|
|
|
Max. load for | 12 Amps |
protection outlets (8 outlets) |
|
|
|
Simulated sine wave form | |
|
|
Operating temperature | 32°F to 95°F |
| 0°C to 35°C |
|
|
Operating relative humidity | 0 to 95 % |
|
|
Size (L × W × H) | 11" × 6 5/8" × 3 1/2" |
| 28 cm × 16.9 cm × 8.7 cm |
|
|
Net weight | 14.3 lbs |
| 6.49 kg |
|
|
Typical battery recharge time | 8 hours typical from total |
| discharge |
|
|
Typical battery life | 3 to 6 years, depending on |
| number of discharge/recharge |
| cycles |
|
|
EXPECTED RUNTIME IN MINUTES
Because of the differences in computer components, the runtime will vary.
Model | Runtime |
|
|
iMac G4 | 70 minutes |
|
|
Desktop PC with | 45 minutes |
LCD monitor |
|
|
|
Desktop PC with | 28 minutes |
15" monitor |
|
|
|
Desktop PC with | 22 minutes |
17" monitor |
|
|
|
Desktop PC with | 16 minutes |
21" monitor |
|
|
|
Legal notices
©2005 Dynex. DYNEX and the DYNEX logo are trademarks of Best Buy Enterprise Services, Inc. Other brands and product names are trademarks or registered trademarks of their respective holders. Specifications and features are subject to change without notice or obligation.
Support number: (800) 305-2204
URL: www.dynexproducts.com