Cabletron Systems 9H531-24, 9H532-24, 9H533-24 System Diagnostic Controller, SMB-1 Bus, SMB-10 Bus

Page 31

Technical Overview

SMB-1 Bus

The SMB-1 is a 1 Mbps management bus located within the SmartSwitch 9000. This bus is utilized by all diagnostic controllers in the system including connectivity modules, power supply modules and the environmental module. The SMB-1 transports inter-chassis information between system components, such as power and environmental information, as well as diagnostic messages. Periodic loop-back tests are performed by all modules that share this bus to ensure the validity of SMB-1. In the event a failure is detected on SMB-1, the SMB-10 may be used as an alternate communication channel.

SMB-10 Bus

The SMB-10 is a 10 Mbps management bus located within the SmartSwitch 9000, which is also used for inter-chassis communication of modules as well as serving as an out-of-band management channel into the SmartSwitch 9000. The SMB-10 is externalized from the chassis via an optional Ethernet Port Interface Module (EPIM) located on the front of the Environmental Module. Through an EPIM connection, full SNMP management of the SmartSwitch 9000 is available out-of- band from user data. Modules that share the SMB-10 bus periodically send out loop-back packets to ensure the validity of SMB-10. In the event a fault is detected on the SMB-10, the SMB-1 can be used as an alternate communication channel by the modules.

System Diagnostic Controller

This diagnostic controller is composed of a Z-80 microprocessor and its supporting logic. The diagnostic controller is designed to control the power-up sequencing of modules, monitor the 9H532-24, 9H533-24, 9H531-24 and 9H539-24 input and output power parameters, keep watch over the main host processor, as well as monitor the temperature and control the SMB LANVIEW diagnostic LED. Although the diagnostic controller and the main host processor can operate independent of each other if needed, they exchange information about each otherÕs status and overall module condition. The information gathered by the diagnostic controller is available to the network manager via local/remote management and the LCD located on the Environmental Module. The 9H532-24, 9H533-24, 9H531-24 and 9H539-24 have been designed so that in the event of a diagnostic controller fault, the 9H532-24, 9H533-24, 9H531-24 and 9H539-24 will continue to function.

3-3

Image 31
Contents 9033050-02 Page FCC Notice Cabletron SYSTEMS, INC Program License Agreement Iii Cabletron Systems Limited Program License Agreement Page Page Declaration of Conformity Viii Contents Contents Introduction FeaturesIntroduction Auto-Negotiation Management Broadcast Suppression Priority Indicator Transmit Queue Switching Options Related Manuals Introduction Unpacking the Module User Accessible ComponentsInstalling the SmartSwitch 9000 Module Switch Function Description Using DIP Switch Installing the Module into the SmartSwitch 9000 ChassisInstalling the Module Reset Switch Reset Switch100BASE-FX Network Cabling Requirements10BASE-T Network 100BASE-TX NetworkInstalling the SmartSwitch 9000 Module Technical Overview SmartSwitch ArchitectureTechnical Overview System Management BusesSMB-1 Bus System Diagnostic ControllerSMB-10 Bus INB Interface DC/DC ConverterI960 Core Lanview LEDs LED Mode SwitchLanview LEDs Functions of the INB transmit LED are listed in Table Functions of the INB receive LED are listed in Table DPX Status LEDs 9H532-24 only Lanview LEDs Technical Specifications SpecificationsRegulatory Compliance ServicePhysical