Technical Overview
DC/DC Converter
The DC/DC converter converts the 48 VDC on the system power bus to the necessary operating voltages for its host network services module. The diagnostic controller monitors and controls the operation of the DC/DC converter.
INB Interface
Each module attaches to both INB A and INB B and has two INB ASICs. The INB ASICs use
The 9X5XX modules are fully compatible with the the Þrst generation 9X4XX modules. The Þrst generation modules communicate only on INB B using a
66 MHz Ethernet frames, to the Þrst generation compatible 40 MHz canonical frame on INB B only. INB A is used only by the 9X5XX modules and remains at the higher speed.
i960 Core
The i960 core provides modules host services, the SNMP protocol stacks, to support industry standard MIBs, as well as Cabletron enterprise extension MIBs for each media type. Management services, such as telnet, WebView and network address to MAC address mapping, are also provided by the i960 core.