Cabletron Systems 9H533-24, 9H532-24, 9H531-24 manual

Page 8

Notice

SAFETY INFORMATION

CLASS 1 LASER TRANSCEIVERS

THE 9H539-24 MODULE USES CLASS 1 LASER TRANSCEIVERS.

READ THE FOLLOWING SAFETY INFORMATION BEFORE

INSTALLING OR OPERATING THESE MODULES.

The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop eliminates the need for maintenance checks or adjustments. The output is factory set, and does not allow any user adjustment. Class 1 Laser transceivers comply with the following safety standards:

21 CFR 1040.10 and 1040.11 U.S. Department of Health and Human Services (FDA).

IEC Publication 825 (International Electrotechnical Commission).

CENELEC EN 60825 (European Committee for Electrotechnical Standardization).

When operating within their performance limitations, laser transceiver output meets the Class 1 accessible emission limit of all three standards. Class 1 levels of laser radiation are not considered hazardous.

SAFETY INFORMATION

CLASS 1 LASER TRANSCEIVERS

LASER RADIATION AND CONNECTORS

When the connector is in place, all laser radiation remains within the fiber. The maximum amount of radiant power exiting the fiber (under normal conditions) is -12.6 dBm or 55 x 10-6watts.

Removing the optical connector from the transceiver allows laser radiation to emit directly from the optical port. The maximum radiance

from the optical port (under worst case conditions) is 0.8 W cm-2or 8 x 103 W m2 sr-1.

Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. When viewing the output optical port, power must be removed from the network adapter.

vi

Image 8
Contents 9033050-02 Page FCC Notice Cabletron SYSTEMS, INC Program License Agreement Iii Cabletron Systems Limited Program License Agreement Page Page Declaration of Conformity Viii Contents Contents Features IntroductionIntroduction Auto-Negotiation Management Broadcast Suppression Priority Indicator Transmit Queue Switching Options Related Manuals Introduction User Accessible Components Unpacking the ModuleInstalling the SmartSwitch 9000 Module Switch Function Description Installing the Module into the SmartSwitch 9000 Chassis Using DIP SwitchInstalling the Module Reset Switch Reset SwitchCabling Requirements 10BASE-T Network100BASE-TX Network 100BASE-FX NetworkInstalling the SmartSwitch 9000 Module SmartSwitch Architecture Technical OverviewSystem Management Buses Technical OverviewSMB-10 Bus System Diagnostic ControllerSMB-1 Bus I960 Core DC/DC ConverterINB Interface LED Mode Switch Lanview LEDsLanview LEDs Functions of the INB transmit LED are listed in Table Functions of the INB receive LED are listed in Table DPX Status LEDs 9H532-24 only Lanview LEDs Specifications Technical SpecificationsPhysical ServiceRegulatory Compliance