Single Mode and Multimode Fiber Optic Cabling
Table
IBM | Max. Lobe Length | Max. Drive Distance | ||
|
|
|
| |
Type | 4 Mbps | 16 Mbps | 4 Mbps | 16 Mbps |
| ||||
|
|
|
|
|
|
|
|
|
|
1 & 2 | 200 meters | 100 meters | 770 meters | 346 meters |
| (660 feet) | (300 feet) | (2525 feet) | (1138 feet) |
|
|
|
|
|
6 & 9 | 30 meters | 30 meters | 513 meters | 230 meters |
| (99 feet) | (99 feet) | (1683 feet) | (755 feet) |
|
|
|
|
|
B.3 Single Mode and Multimode Fiber Optic Cabling
TPIM models F2 and F3 support multimode and singlemode fiber optic cable respectively. Table
Table
|
| Total | Maximum |
|
| Allowable | |
| Cable Type | Drive Distance | |
| Attenuation | ||
|
|
| |
|
|
|
|
Multimode | 50/125 ∝m | 13.0 dB or less | 2 km (2187.2 yards) |
|
|
| |
62.5/125 ∝m | 16.0 dB or less |
| |
|
| ||
|
|
|
|
| 100/140 ∝m | 19.0 dB or less |
|
|
|
|
|
| Typical Signal Attenuation Rate: ≤ 2.5 dB/km. | ||
|
|
|
|
Single | 10.0 dB or less | 10 km (10936.0 yards). | |
|
|
| |
Typical Signal Attenuation Rate: ≤ 0.5 dB/km. | |||
|
|
|
|
NOTE |