To connect a fiber optic link segment to the EMC39-12, perform the following steps:

1.Remove the protective plastic covers from the fiber optic ports on the applicable port on the module and from the ends of the connectors on each fiber strand.

2.Attach the fiber labeled 1 to the applicable Receive port, labeled RX, on the module. See Figure 3-2.

EMC39-12Ethernet Media Converter WITH LANVIEW

TPLINK

 

 

XMT

RX TX

RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX

RCV

 

 

PWR FOLNK

12 11 10 9 8 7 6 5 4 3 2 1

12

11

10

9

8

7

6

5

4

3

2

1

 

Figure 3-2 Connecting a Fiber Link to the EMC39-12

3.Attach the fiber labeled 2 to the applicable Transmit port labeled TX, on the module.

4.At the other end of the fiber optic cable, attach the fiber labeled 1 to the Transmit port of the device.

5.Attach the fiber labeled 2 to the Receive port.

6.Check that the FOLNK LED on the ECM39-12 is on. If the LED is not on, perform the following steps until it is:

a.Check that the power is turned on for the device at the other end of the link.

b.Verify proper “receive to transmit” connection of fiber strands between the applicable port on the module and the fiber optic device at the other end of the fiber optic link segment.

c.Verify that the fiber connection meets the dB loss specifications outlined in Appendix A.

If a link still has not been established, contact Cabletron Systems Technical Support.

Page 3-4

EMC39-12 User’s Guide

Image 19
Contents EMC39-12Ethernet Media Converter with Lanview Port Ethernet Media Converter USER’S GuidePage EMC39-12 User’s Guide FCC Notice Cabletron SYSTEMS, INC. Program License Agreement United States Government Restricted Rights Table of Contents Chapter Introduction Using this ManualEMC39-12 Overview Getting HelpAutomatic Transmit Port Disable EMC39-12 FeaturesEnvironmental Requirements EMC39-12 SpecificationsInstalling the EMC39-12 Chapter InstallationUnpacking the EMC39-12 Rack Mounting the EMC39-12 Free-Standing Shelf or Tabletop Installation Connecting the EMC39-12 to the Power Source Connecting a Twisted Pair Segment to the EMC39-12 Chapter Connecting to the NetworkConnecting To The Network Connecting a Fiber Optic Link Segment Connecting a Fiber Link to the EMC39-12 Finishing the Installation EMC39-12 Chapter Using the Lanview LedsRCV Receive Appendix a Cable Requirements Single Mode Fiber Optic Network10BASE-T Twisted Pair Requirements A-2 EMC39-12 User’s Guide Twisted Pair Wiring from AN EMC39-12 to a Punch Down Block Appendix B Twisted Pair Wiring TablesB-2 EMC39-12 User’s Guide Twisted Pair Wiring From An EMC39-12 To a Punch Down Block B-4 EMC39-12 User’s Guide Twisted Pair Wiring from a Punch Down bLOCK to a B-6 EMC39-12 User’s Guide EMC39-12 User’s Guide B-7 B-8 EMC39-12 User’s Guide Power Supply Cord