Extron electronic MC104 IP setup guide Software Setup, Download Device Drivers, IP model only

Page 13

Software Setup

This chapter provides the steps for setting up your

MLC 104 series controller using the Global Configurator (GC) software. By means of example, you will learn how to

Add drivers that allow control of A/V devices.

Configure the controller's power buttons, and input selection buttons to control a video projector.

Schedule a projector shutdown, create a lamp hour warning alert, and create a projector disconnection e-mail alert.

Each of the following steps of configuration are described in detail in the subsequent sections of this chapter.

1Downloading device drivers

2Creating a new project

3Adding an MLC 104 or MLC 104 IP controller and defining its location

4Defining e-mail settings (IP model only)

5Adding serial or IR devices

6Configuring the front panel buttons

7Creating a display shutdown schedule

8Creating a display lamp hour warning e-mail

(IP model only)

9Creating a display disconnection e-mail (IP model only)

10Building and uploading a configuration

NThis setup guide provides instructions for the primary setup and configuration of the MLC 104. For additional information and more detailed instructions, refer to the MLC 104 Series User's Manual or the GC Help file accessed through the GC software.

CYou must use Global Configurator version 2.2 or later to configure the MLC 104 series. Using an earlier version (2.0.0 through 2.1.x) risks damage to the products. Immediately update any existing controllers configured with older versions of the software. See "Installing the Software" in chapter 1 for instructions on how to install GC 2.2.

Step 1: Download Device Drivers

In order to configure an MLC to control a device, you must download the drivers for each device.

For the purposes of this setup guide and tutorial, you will download two drivers to use in the following examples: one serial driver (for a video projector) and one IR driver (for a DVD/VCR player).

If you prefer to download the drivers required for your own configuration, replace our example drivers with your own in the following exercises.

To download the required drivers, do the following:

1.Double-click the GC icon to launch Global Configurator.

The GC 2 Start Options dialog box appears.

2.Click the Add Drivers Subscription button.

3a. From the Available Manufacturers/Device Types box, choose the required manufacturer(s) from the left window by clicking its name. For the following exercises, choose Epson.

3b. From the Available Manufacturers/Device Types box, choose the required device(s) from the right window by clicking its icon. For the following exercises, choose video projector.

4.From the far right column of buttons, click the Subscribe button. The selected items appear in the Current Driver Subscriptions window.

5. Repeat steps 3-5above, choosing Hitachi as the manufacturer and DVD/VCR as the device.

6.Click the Download button to download the drivers under the Current Driver Subscriptions window.

NIf you wish to unsubscribe to a particular driver, check its check box and then click the Unsubscribe button.

7.After all of your drivers are successfully subscribed, click the OK button. The GC 2 Start Options dialog reappears.

NWhen adding new drivers to an open project, you must close (and save) the configuration for a successful download. Reopen the configuration to view the downloaded drivers. See "Step 5: Add Serial and IR Devices" for detailed instructions.

3-2

MLC 104 Series MediaLink Controllers • Software Setup

MLC 104 Series MediaLink Controllers • Software Setup

3-3

Image 13 Contents
MLC 104 and MLC 104 IP Series Precautions 安全须知 中文 Table of Contents MLC 104 MediaLink Controllers Table of Contents, cont’dIntroduction About Global ConfiguratorAbout this Manual About the MLC 104 Medialink ControllersIntroduction, cont’d Installing the SoftwareSystem Requirements Updating FirmwareTwo Right Side Panel Features and Connections Hardware SetupAn MLC 104 series controller daisy chained to a SCP Power wiring Hardware Setup, cont’dButtons Left SideConfiguration host control port Volume controlPin out for TRS RS-232 cable wiring Baud Stop bit No parity Data bits No flow controlDownload Device Drivers Software SetupIP model only Project Settings dialog box Software Setup, cont’d Create a New ProjectAdd Device dialog box Basic for IP version only MLC 104 IPGlobal Configurator Front Panel window Software Setup, cont’dAdd Device dialog box Advanced for IP version only Setting up e-mail notifications Defining e-mail server settingsEmail Manager dialog box Add a Serial or IR Device MLC 104 series port configurationAdding e-mail contacts Downloading additional driversAdd IR Driver window Add Serial Driver windowConfiguring an input button Software Setup, cont’d Configure the Front Panel ButtonsConfiguring the On and Off buttons Front Panel window with configured buttonsScheduled Actions Wizard Software Setup, cont’d Create a Display Shutdown ScheduleDisplay shutdown action selection dialog Monitored Conditions Wizard dialog Conditions dialog. The Monitored Conditions WizardUnder the Available Options window Available Options windowBuilding a configuration Build and Upload a ConfigurationCreate a Display Disconnection E-mail IP model only Display lamp hour e-mail notificationAccessing GlobalViewer Uploading a configurationUpload Manager window before file upload GlobalViewer main