Extron electronic MC104 IP Software Setup, cont’d Create a Display Shutdown Schedule

Page 20

Software Setup, cont’d

Step 7: Create a Display Shutdown Schedule

Global Configurator’s (GC) scheduling feature enables you to schedule actions and events for a selected device. Scheduling is often useful for setting a projector or other device to shut down or turn on at a predetermined time (e.g., in a school, all projectors can be set to power off at 5:00 P.M.).

To schedule a display shutdown:

1.

Click on the Schedule tab in the Global Configurator

 

window.

2.

Click the Add Schedule button below the Scheduled

 

Actions window. The Scheduled Actions Wizard dialog

 

box appears.

Scheduled Actions Wizard

3.

Enter a name (e.g., Shutdown) in the Enter Scheduled

 

Action Name field.

4.

Indicate the time for the desired action and uncheck

 

inactive times (e.g., weekend hours when staff are away).

For events that occur at the same time daily, change the time alongside the Set All button. Click the Set All button to automatically change all selected days of the week.

5. Click Next. This takes you to the actions page, where you can specify the action.

Display shutdown action selection dialog

6.

Select the device to be scheduled (for our purposes,

 

choose the Epson PowerLite 7700p) from the Subject Port

 

window.

7.

Select the action Power Control Off from the Available

 

Options window, then click the Apply Action button.

8.

Click Done. The dialog box closes.

3-16 MLC 104 Series MediaLink Controllers • Software Setup

MLC 104 Series MediaLink Controllers • Software Setup 3-17

Image 20
Contents MLC 104 and MLC 104 IP Series Precautions 安全须知 中文 Table of Contents Table of Contents, cont’d MLC 104 MediaLink ControllersAbout Global Configurator IntroductionAbout this Manual About the MLC 104 Medialink ControllersInstalling the Software Introduction, cont’dSystem Requirements Updating FirmwareTwo An MLC 104 series controller daisy chained to a SCP Hardware SetupRight Side Panel Features and Connections Hardware Setup, cont’d Power wiringLeft Side ButtonsVolume control Configuration host control portPin out for TRS RS-232 cable wiring Baud Stop bit No parity Data bits No flow controlIP model only Software SetupDownload Device Drivers Software Setup, cont’d Create a New Project Project Settings dialog boxAdd Device dialog box Basic for IP version only MLC 104 IPAdd Device dialog box Advanced for IP version only Software Setup, cont’dGlobal Configurator Front Panel window Email Manager dialog box Defining e-mail server settingsSetting up e-mail notifications MLC 104 series port configuration Add a Serial or IR DeviceAdding e-mail contacts Downloading additional driversAdd Serial Driver window Add IR Driver windowSoftware Setup, cont’d Configure the Front Panel Buttons Configuring an input buttonConfiguring the On and Off buttons Front Panel window with configured buttonsDisplay shutdown action selection dialog Software Setup, cont’d Create a Display Shutdown ScheduleScheduled Actions Wizard Conditions dialog. The Monitored Conditions Wizard Monitored Conditions Wizard dialogUnder the Available Options window Available Options windowBuild and Upload a Configuration Building a configurationCreate a Display Disconnection E-mail IP model only Display lamp hour e-mail notificationUploading a configuration Accessing GlobalViewerUpload Manager window before file upload GlobalViewer main