Step 8: Create a Display Lamp Hour Warning

E-mail (IP model only)

Global Configurator’s monitoring feature enables you to configure a MLC 104 IP controller to monitor many parameters of the connected display devices. For example, a monitor alert can warn the school administrator if a display lamp hour limit is close to expiration, or if a display is inexplicably disconnected from the MLC 104 IP controller.

To set a display lamp hour warning e-mail, do the following:

1.

Click the Monitor tab in the Global Configurator window.

2.

Click the Add Monitor button below the Monitored

 

Conditions dialog. The Monitored Conditions Wizard

 

dialog appears.

3.

Enter a name (e.g., Lamp hour) in the Enter Monitored

 

Condition Name field area. The label now appears in the

 

left pane.

4.

Click the Next button to specify a condition. This takes

 

you to the actions page, where you can specify the action.

Monitored Conditions Wizard dialog

5.

In the Subject Port window, select the display

 

(choose Epson PowerLite 7700p) for which the lamp hour

 

warning is to be set. A list of monitoring options appears

 

under the Available Options window.

6.

Set the lamp hour limit by doing the following:

 

a.

Choose Lamp Usage Time (hours): Value under the

 

 

Available Options window.

 

b.

Enter a value (e.g., 800) in the Lamp Usage Time

 

 

(hours) box.

 

c.

Click Apply Condition for each condition assigned.

 

d.

Click Next.

7.

Click Next again to add an e-mail notification.

8.

Click on the appropriate e-mail message and contacts,

 

then click Apply Email/Contacts.

3-18 MLC 104 Series MediaLink Controllers • Software Setup

MLC 104 Series MediaLink Controllers • Software Setup 3-19

Image 21 Contents
MLC 104 and MLC 104 IP Series Precautions 安全须知 中文 Table of Contents MLC 104 MediaLink Controllers Table of Contents, cont’dIntroduction About Global ConfiguratorAbout this Manual About the MLC 104 Medialink ControllersIntroduction, cont’d Installing the SoftwareSystem Requirements Updating FirmwareTwo Hardware Setup Right Side Panel Features and ConnectionsAn MLC 104 series controller daisy chained to a SCP Power wiring Hardware Setup, cont’dButtons Left SideConfiguration host control port Volume controlPin out for TRS RS-232 cable wiring Baud Stop bit No parity Data bits No flow controlSoftware Setup Download Device DriversIP model only Project Settings dialog box Software Setup, cont’d Create a New ProjectAdd Device dialog box Basic for IP version only MLC 104 IPSoftware Setup, cont’d Global Configurator Front Panel windowAdd Device dialog box Advanced for IP version only Defining e-mail server settings Setting up e-mail notificationsEmail Manager dialog box Add a Serial or IR Device MLC 104 series port configurationAdding e-mail contacts Downloading additional driversAdd IR Driver window Add Serial Driver windowConfiguring an input button Software Setup, cont’d Configure the Front Panel ButtonsConfiguring the On and Off buttons Front Panel window with configured buttonsSoftware Setup, cont’d Create a Display Shutdown Schedule Scheduled Actions WizardDisplay shutdown action selection dialog Monitored Conditions Wizard dialog Conditions dialog. The Monitored Conditions WizardUnder the Available Options window Available Options windowBuilding a configuration Build and Upload a ConfigurationCreate a Display Disconnection E-mail IP model only Display lamp hour e-mail notificationAccessing GlobalViewer Uploading a configurationUpload Manager window before file upload GlobalViewer main