Ethernet/LAN

bLAN port — Plug an RJ-45 jack into this socket to connect the unit to a computer network. Use a straight-through cable to connect to a switch, hub, or router, and a crossover cable to connect directly to a PC.

Activity LED — A blinking yellow LED indicates LAN activity.

Link LED — A green LED lights to indicate a good LAN connection.

LAN

RJ-45

Port

Link

LED

Activity

LED

Pins:

12345678

Insert Twisted

Pair Wires

RJ-45

Connector

Crossover Cable

 

End 1

End 2

Pin

Wire color

Wire color

1

White-green

White-orange

 

 

 

2

Green

Orange

3

White-orange

White-green

 

 

 

4

Blue

Blue

5

White-blue

White-blue

6

Orange

Green

7

White-brown

White-brown

 

 

 

8

Brown

Brown

 

T568A

T568B

A cable that is wired as T568A at one end and T568B at the other (Tx and Rx pairs reversed) is a "crossover" cable.

Straight-through Cable

Pin

End 1

End 2

Wire color

Wire color

1

White-orange

White-orange

 

 

 

2

Orange

Orange

3

White-green

White-green

 

 

 

4

Blue

Blue

5

White-blue

White-blue

6

Green

Green

7

White-brown

White-brown

 

 

 

8

Brown

Brown

 

T568B

T568B

A cable wired the same at both ends is called a "straight-through" cable, because no pin/pair assignments are swapped.

Figure 7. RJ-45 Connector Wiring

Connections

cContact closure — Four inputs permit connection of switches and sensors to provide input (trigger events) to the system.

dRelay ports — Eight relay ports provide contact closure activation of relays for power, screen projector lift control, drapes, and so on, when trigger events occur.

Indentification

eMAC address — The unique hardware ID number (MAC address) of the unit (for example, 00-05-A6-00-00-01)

Operation

Connect power cords and turn on the output devices (such as projector lifts, screen lifts, and lights), input (trigger) devices (such as motion detectors, and alarms), controller, and network devices (PC, laptop, and network equipment).

Check indicator LEDs on the PC or laptop, on the unit, on the network hub or router, and so on, to ensure that all devices are plugged in and communicating. The IPL T CR48 is ready to be configured (see the Connection and Configuration section).

See Troubleshooting in the “Connection and Configuration” section for information if connection or communication problems occur. If the troubleshooting tips do not help, check with your local network administrator, or call the Extron S3 Sales and Technical Support Hotline.

IPL T CR48 • Installation and Operation

7

Image 13
Contents IPL T CR48 Precaucion AchtungAvertissement VorsichtCopyright Page Contents IPL T CR48 Contents Introduction FeaturesAbout this Guide About the IPL T CR48Easily configured and controlled Installation Overview Installation OperationMounting the IPL T CR48 Rack Mounting UL Guidelines for Rack MountingFurniture or Projector Mounting Rear Panel Features and CablingPower Connector Wiring PowerEthernet/LAN OperationConnections IndentificationResetting the Controller Front Panel IndicatorsMode Activation Result Purpose and Notes IPL T CR48 Reset Mode SummaryUse EventsConnecting the Hardware Connection ConfigurationEthernet Connection ExtronPC Configuration Configuring the HardwareContact Closure Input and Relay Connections Contact closure input connectionsConfiguring the IPL T CR48 using the ARP command IPL T CR48 Interface ConfigurationInitial start up Executing the ARP Command Firmware upgrades Configuring the IPL T CR48 using direct PC connectionSelect Internet Protocol TCP/IP from the list Ports Overview Communication ControlContact Closure Input Ports Relay Ports Communication with the InterfaceWeb Server Enter Network Password Dialog Box Accessing and using the Web serverSetting and changing your passwords Establishing or changing system or port settingsSubmit Passwords ScreenEmail Alerts screen Editing and adding e-mail alertsUpgrading the firmware Firmware Upgrade ScreenFile Management Screen Managing filesProgrammer’s Guide for the Telnet and Web Browser Using the Command/Response TableASCII-to-HEX Conversion Table Symbol definitionsCopyright information Password informationURL Encoding Error responsesUnsafe characters Reserved charactersRelay Functions Command Ascii Telnet URL Encoded Web ResponseInput Contact Closure Port Firmware Version/Part Number/InformationIPL T CR48 Communication IP Setup CommandsRe-map Port Designations File CommandsMail Web Browser SpecificEvent Control Reset Zap/Erase Commands Device Control Accessing and using TelnetCustom Web Pages Telnet PortPower Connections TroubleshootingConfiguration Data ConnectionsSpecifications Specifications Part NumbersIncluded Parts Replacement Part Number AccessoriesAccessories Part Number Part NumbersGlossary IPL T CR48 Glossary Europe, Africa, and the Middle China East USA, Canada, South America Japan Central AmericaAsia Middle East EuropeExtron Middle East
Related manuals
Manual 66 pages 29.57 Kb

IPL T CR48 specifications

The Extron IPL T CR48 is a cutting-edge technology solution designed for modern audiovisual environments. As a compact, high-performance control processor, it is specifically tailored for managing and automating AV systems in various settings, including classrooms, conference rooms, and other collaborative spaces. The IPL T CR48 seamlessly integrates with a wide range of Extron products and third-party devices, making it a versatile choice for any AV installation.

One of the main features of the IPL T CR48 is its powerful control capabilities. It supports up to 48 programmable control ports, which allow users to manage multiple displays, projectors, and other audiovisual equipment effortlessly. This extensive control range ensures that every device in the AV system is easily operable from a single interface, streamlining the user experience.

In addition to its impressive control capabilities, the IPL T CR48 integrates advanced IPLink technology. This unique feature allows for remote control and monitoring of AV systems over an IP network, offering system administrators the flexibility to manage equipment from virtually anywhere. This capability is particularly valuable in large installations, where managing multiple systems simultaneously can be complex and time-consuming.

The IPL T CR48 also boasts a user-friendly interface, thanks to its compatibility with Extron's GlobalViewer Enterprise software. This robust software provides users with a web-based platform for real-time monitoring and management of their AV systems. It enables users to configure, schedule, and control their AV devices, ensuring a smooth operation throughout all events and presentations.

Moreover, the IPL T CR48 is engineered with enhanced security features, including customizable user access levels, ensuring that only authorized personnel can control sensitive equipment. This aspect is crucial for educational and corporate environments, where security and privacy are paramount.

Compact and reliable, the IPL T CR48 excels in both functionality and performance. Its durable design and advanced technologies make it a preferred choice among AV professionals looking to improve the efficiency of their installations. Overall, the Extron IPL T CR48 represents a significant advancement in control processing technology, providing a comprehensive solution for diverse audiovisual applications today.