Extron electronic manual IP Setup Commands, IPL T CR48 Communication

Page 35

Command/response table for SIS commands (continued)

Command

ASCII (Telnet)

URL Encoded (Web)

Response

IP Setup Commands

IPL T CR48 • Communication

Set Unit name24

Set Unit name to factory default24 Read Unit name

 Set time/date24 Read time/date Set GMT offset24 Read GMT offset

Set daylight saving time Read daylight saving time Set DHCP on24

Set DHCP off24 View DHCP mode Set IP address24 Read IP address

Read hardware address (MAC) Set subnet mask

Read subnet mask

Set gateway IP address Read gateway IP address24 Set administrator password24 Clear administrator password24 Read administrator password24 Set user password24

EX1@ CN}

W X1@ CN

Ipn • X1@]

E • CN}

W %20 CN

Ipn • X4(]

E CN}

WCN

 

X1@]

E X1# CT}

W X1# CT

Ipt • X1#]

E CT}

WCT

 

X1#]

EX# CZ}

W X# CZ

Ipz X#]

E CZ}

WCZ

 

X#]

EX3$ CX}

W X3$ CZ

Ipx X3$]

E CX}

WCX

 

X3$]

E 1DH}

W1DH

 

Idh1]

E 0DH}

W0DH

 

Idh0]

E DH}

WDH

 

X%]

EX1$ CI}

W X1$ CI

Ipi • X1$]

E CI}

WCI

 

 

X1$]

E CH}

WCH

 

X1*]

EX1(  }

X1(

 CS

X1(]

  CS

W 

 

Ips • 

E CS}

WCS

 

X1(]

EX1$ CG}

W X1$ CG

Ipg • X1$]

E CG}

WCG

 

X1$]

EX3# CA}

W X3# CA

Ipa • X3#]

E • CA}

W %20 CA

Ipa • ]

E CA}

WCA

 

X3#]

EX3# CU}

W X3# CU

Ipu • X3#]

and Control 29

NOTE: X#  = Greenwich Mean Time (GMT) offset value (-12.0 to +14.0)

X%  = On/off status: 0 = off/disable; 1 = on/enable

X1@

= Name is a text string up to 24 characters drawn from the alphabet, digits, minus sign/hyphen. No blank or space characters are permitted.

X1#

= Set local date and time format (MM/DD/Y-HH:MM:SS); Read local date and time format (day of week, date month year HH:MM:SS)

X1$

= IP address

X1*

= Hardware (MAC) address

X1(  = Subnet mask

X3#

= Password: maximum length of 12 characters and no special characters

X3$

= Daylight saving time: 0 = off/ignore; 1 = on (use in northern hemisphere) (USA); 2 = on (Europe); 3 = on (Brazil)

X4(

= Default Name: combination of model name and last 3 pairs of MAC address.

Image 35
Contents IPL T CR48 Vorsicht AchtungPrecaucion AvertissementCopyright Page Contents IPL T CR48 Contents About the IPL T CR48 FeaturesIntroduction About this GuideEasily configured and controlled Mounting the IPL T CR48 Installation OperationInstallation Overview Rack Mounting UL Guidelines for Rack MountingFurniture or Projector Mounting Rear Panel Features and CablingPower Connector Wiring PowerIndentification OperationEthernet/LAN ConnectionsResetting the Controller Front Panel IndicatorsEvents IPL T CR48 Reset Mode SummaryMode Activation Result Purpose and Notes UseExtron Connection ConfigurationConnecting the Hardware Ethernet ConnectionContact closure input connections Configuring the HardwarePC Configuration Contact Closure Input and Relay ConnectionsInitial start up IPL T CR48 Interface ConfigurationConfiguring the IPL T CR48 using the ARP command Executing the ARP Command Select Internet Protocol TCP/IP from the list Configuring the IPL T CR48 using direct PC connectionFirmware upgrades Contact Closure Input Ports Communication ControlPorts Overview Web Server Communication with the InterfaceRelay Ports Enter Network Password Dialog Box Accessing and using the Web serverSetting and changing your passwords Establishing or changing system or port settingsSubmit Passwords ScreenEmail Alerts screen Editing and adding e-mail alertsUpgrading the firmware Firmware Upgrade ScreenFile Management Screen Managing filesProgrammer’s Guide for the Telnet and Web Browser Using the Command/Response TableASCII-to-HEX Conversion Table Symbol definitionsCopyright information Password informationURL Encoding Error responsesUnsafe characters Reserved charactersFirmware Version/Part Number/Information Command Ascii Telnet URL Encoded Web ResponseRelay Functions Input Contact Closure PortIPL T CR48 Communication IP Setup CommandsRe-map Port Designations File CommandsEvent Control Web Browser SpecificMail Reset Zap/Erase Commands Telnet Port Accessing and using TelnetDevice Control Custom Web PagesData Connections TroubleshootingPower Connections ConfigurationSpecifications Specifications Part NumbersPart Numbers AccessoriesIncluded Parts Replacement Part Number Accessories Part NumberGlossary IPL T CR48 Glossary Europe USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle EastExtron Middle East
Related manuals
Manual 66 pages 29.57 Kb

IPL T CR48 specifications

The Extron IPL T CR48 is a cutting-edge technology solution designed for modern audiovisual environments. As a compact, high-performance control processor, it is specifically tailored for managing and automating AV systems in various settings, including classrooms, conference rooms, and other collaborative spaces. The IPL T CR48 seamlessly integrates with a wide range of Extron products and third-party devices, making it a versatile choice for any AV installation.

One of the main features of the IPL T CR48 is its powerful control capabilities. It supports up to 48 programmable control ports, which allow users to manage multiple displays, projectors, and other audiovisual equipment effortlessly. This extensive control range ensures that every device in the AV system is easily operable from a single interface, streamlining the user experience.

In addition to its impressive control capabilities, the IPL T CR48 integrates advanced IPLink technology. This unique feature allows for remote control and monitoring of AV systems over an IP network, offering system administrators the flexibility to manage equipment from virtually anywhere. This capability is particularly valuable in large installations, where managing multiple systems simultaneously can be complex and time-consuming.

The IPL T CR48 also boasts a user-friendly interface, thanks to its compatibility with Extron's GlobalViewer Enterprise software. This robust software provides users with a web-based platform for real-time monitoring and management of their AV systems. It enables users to configure, schedule, and control their AV devices, ensuring a smooth operation throughout all events and presentations.

Moreover, the IPL T CR48 is engineered with enhanced security features, including customizable user access levels, ensuring that only authorized personnel can control sensitive equipment. This aspect is crucial for educational and corporate environments, where security and privacy are paramount.

Compact and reliable, the IPL T CR48 excels in both functionality and performance. Its durable design and advanced technologies make it a preferred choice among AV professionals looking to improve the efficiency of their installations. Overall, the Extron IPL T CR48 represents a significant advancement in control processing technology, providing a comprehensive solution for diverse audiovisual applications today.