Extron electronic IPL T CR48 manual Glossary

Page 43

Glossary

This section provides definitions of terms related to the IPL T CR48.

10/100Base-TEthernet that uses Unshielded Twisted Pair (such as UTP - CAT 5) cable, where the amount of data transmitted between two points in a given amount of time is equal to either 10 Mbps or 100 Mbps.

Address Resolution Protocol (ARP) — ARP is a protocol which assigns an IP address to a device based on the MAC or physical machine address of the device.

Contact Closure — An encapsulated switch containing two metal wires that serve as the contact points. When these contact points meet, it creates a complete circuit (for example, ports 1 through 4 to ground on the IPL T CR48).

Custom Web page — Any file that can be loaded into an IPL T CR48 and served by the unit’s internal Web server. A custom Web page can provide control of devices attached to the IPL T CR48 without use of the GlobalViewer® (GV) or Global Configurator (GC). This is true with or without an accompanying event script. Any number and size of graphics can be used, but if they are too large to fit on the IPL T CR48, you can write your Web page so that they can be served from another Web server. If you install Microsoft® Internet Information Services (IIS) on your desktop, you can serve any page on its hard disk. The IPL T CR48 functions like a small computer with a Web server — you can use it for various Web tasks.

DHCP — Dynamic Host Configuration Protocol (DHCP), which is a standardized communications protocol that enables network administrators to locally and automatically manage the assignment of IP addresses in a network for an organization.

Driver — A GC compatible package. It includes the event script that controls devices.

Ethernet — A network protocol that uses MAC addresses instead of IP addresses to exchange data between computers. Using ARP (see above), with TCP/IP support, Ethernet devices can be connected to the Internet. An Ethernet LAN typically uses unshielded twisted pair (UTP) wires. Ethernet systems currently provide transmission speeds of

10 Mbps or 100 Mbps.

Event script — A program that runs on an IPL T CR48 controller, and issues queries and commands to the attached devices. Event scripts are written in the “Extron C” language (*.sc), and compiled into an event script (*.evt). GC performs this compilation. The compiled result is loaded onto the IPL T CR48. The Extron C language is similar to ANSI C, with some differences. As long as event scripts are turned on, event scripts run continuously on the unit.

Global Configurator (GC) — A Windows® program that, based on user input, creates a GlobalViewer (GV). GC requests system information such as which devices you have and your current list of IP addresses. With this information, GC creates a GlobalViewer for your specific devices. GC also compiles the event scripts and loads the GV and event scripts onto the box. When using GC, you must specify the port number for each device (for attached devices to be controlled, they must be on that port). In order for multiple IP Link® units to appear in the same GV, all the units must be configured at the same time, using GC.

IPL T CR48 • Glossary

37

Image 43
Contents IPL T CR48 Vorsicht AchtungPrecaucion AvertissementCopyright Page Contents IPL T CR48 Contents About the IPL T CR48 FeaturesIntroduction About this GuideEasily configured and controlled Installation Overview Installation OperationMounting the IPL T CR48 Rack Mounting UL Guidelines for Rack MountingFurniture or Projector Mounting Rear Panel Features and CablingPower Connector Wiring PowerIndentification OperationEthernet/LAN ConnectionsResetting the Controller Front Panel IndicatorsEvents IPL T CR48 Reset Mode SummaryMode Activation Result Purpose and Notes UseExtron Connection ConfigurationConnecting the Hardware Ethernet ConnectionContact closure input connections Configuring the HardwarePC Configuration Contact Closure Input and Relay ConnectionsConfiguring the IPL T CR48 using the ARP command IPL T CR48 Interface ConfigurationInitial start up Executing the ARP Command Firmware upgrades Configuring the IPL T CR48 using direct PC connectionSelect Internet Protocol TCP/IP from the list Ports Overview Communication ControlContact Closure Input Ports Relay Ports Communication with the InterfaceWeb Server Enter Network Password Dialog Box Accessing and using the Web serverSetting and changing your passwords Establishing or changing system or port settingsSubmit Passwords ScreenEmail Alerts screen Editing and adding e-mail alertsUpgrading the firmware Firmware Upgrade ScreenFile Management Screen Managing filesProgrammer’s Guide for the Telnet and Web Browser Using the Command/Response TableASCII-to-HEX Conversion Table Symbol definitionsCopyright information Password informationURL Encoding Error responsesUnsafe characters Reserved charactersFirmware Version/Part Number/Information Command Ascii Telnet URL Encoded Web ResponseRelay Functions Input Contact Closure PortIPL T CR48 Communication IP Setup CommandsRe-map Port Designations File CommandsMail Web Browser SpecificEvent Control Reset Zap/Erase Commands Telnet Port Accessing and using TelnetDevice Control Custom Web PagesData Connections TroubleshootingPower Connections ConfigurationSpecifications Specifications Part NumbersPart Numbers AccessoriesIncluded Parts Replacement Part Number Accessories Part NumberGlossary IPL T CR48 Glossary Europe USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle EastExtron Middle East
Related manuals
Manual 66 pages 29.57 Kb

IPL T CR48 specifications

The Extron IPL T CR48 is a cutting-edge technology solution designed for modern audiovisual environments. As a compact, high-performance control processor, it is specifically tailored for managing and automating AV systems in various settings, including classrooms, conference rooms, and other collaborative spaces. The IPL T CR48 seamlessly integrates with a wide range of Extron products and third-party devices, making it a versatile choice for any AV installation.

One of the main features of the IPL T CR48 is its powerful control capabilities. It supports up to 48 programmable control ports, which allow users to manage multiple displays, projectors, and other audiovisual equipment effortlessly. This extensive control range ensures that every device in the AV system is easily operable from a single interface, streamlining the user experience.

In addition to its impressive control capabilities, the IPL T CR48 integrates advanced IPLink technology. This unique feature allows for remote control and monitoring of AV systems over an IP network, offering system administrators the flexibility to manage equipment from virtually anywhere. This capability is particularly valuable in large installations, where managing multiple systems simultaneously can be complex and time-consuming.

The IPL T CR48 also boasts a user-friendly interface, thanks to its compatibility with Extron's GlobalViewer Enterprise software. This robust software provides users with a web-based platform for real-time monitoring and management of their AV systems. It enables users to configure, schedule, and control their AV devices, ensuring a smooth operation throughout all events and presentations.

Moreover, the IPL T CR48 is engineered with enhanced security features, including customizable user access levels, ensuring that only authorized personnel can control sensitive equipment. This aspect is crucial for educational and corporate environments, where security and privacy are paramount.

Compact and reliable, the IPL T CR48 excels in both functionality and performance. Its durable design and advanced technologies make it a preferred choice among AV professionals looking to improve the efficiency of their installations. Overall, the Extron IPL T CR48 represents a significant advancement in control processing technology, providing a comprehensive solution for diverse audiovisual applications today.