Contact Closure Input and Relay Connections

Contact closure input connections

The IPL T CR48 can be connected to any relay providing a closure to ground (closed = logic 1 and open = logic 0). The contact closure inputs are connected to 5 VDC via a 1k ohm pull-up resistor and must be wired with a ground. This allows the input to be tied to devices such as motion detectors and alarms. You can define what this input triggers via control software.

1.Connect one end of the input cable to a 3.5 millimeter, 5-pole captive screw connector, wired appropriately, and plug it into the rear panel input port connector of the unit.

2.Connect the other end of the input cable to the input relay device that will provide a triggering signal.

Relay connections

The IPL T CR48 can be connected to any device that can be activated by a relay closure. This allows the relay to be tied to devices such as lights (preset recall), projector lifts, and screen or drape controllers. You can define what triggers this action via control software.

1.Connect one end of the relay cable to an 8-pole captive screw connector, wired appropriately, and plug it into the rear panel relay port connector of the unit.

2.Connect the other end of the relay cable to the device that will be activated when the triggering signal is received.

Configuring the Hardware

To function together properly, both the controlling PC and the IPL T CR48 must be configured correctly. The PC must be network-capable, with the proper protocols installed and the hardware configured correctly. The IPL T CR48 must be set to recognize and accept commands and pass them through to the projector lift, screen lift, or other controlled device.

PC Configuration

This guide assumes that you have a Microsoft® Windows® PC equipped with an operating network adapter. To allow your PC to work with Extron Ethernet-controlled products, the TCP/IP protocol must be installed and properly configured.

For use on an existing Ethernet LAN intranet, your network administrator can provide you with a unique IP address or confirm whether you need to set up the IPL T CR48 for DHCP (Dynamic Host Configuration Protocol) to have an address assigned automatically when you sign on.

IPL T CR48 • Connection and Configuration

11

Image 17
Contents IPL T CR48 Precaucion AchtungAvertissement VorsichtCopyright Page Contents IPL T CR48 Contents Introduction FeaturesAbout this Guide About the IPL T CR48Easily configured and controlled Mounting the IPL T CR48 Installation OperationInstallation Overview Rack Mounting UL Guidelines for Rack MountingFurniture or Projector Mounting Rear Panel Features and CablingPower Connector Wiring PowerEthernet/LAN OperationConnections IndentificationResetting the Controller Front Panel IndicatorsMode Activation Result Purpose and Notes IPL T CR48 Reset Mode SummaryUse EventsConnecting the Hardware Connection ConfigurationEthernet Connection ExtronPC Configuration Configuring the HardwareContact Closure Input and Relay Connections Contact closure input connectionsInitial start up IPL T CR48 Interface ConfigurationConfiguring the IPL T CR48 using the ARP command Executing the ARP Command Select Internet Protocol TCP/IP from the list Configuring the IPL T CR48 using direct PC connectionFirmware upgrades Contact Closure Input Ports Communication ControlPorts Overview Web Server Communication with the InterfaceRelay Ports Enter Network Password Dialog Box Accessing and using the Web serverSetting and changing your passwords Establishing or changing system or port settingsSubmit Passwords ScreenEmail Alerts screen Editing and adding e-mail alertsUpgrading the firmware Firmware Upgrade ScreenFile Management Screen Managing filesProgrammer’s Guide for the Telnet and Web Browser Using the Command/Response TableASCII-to-HEX Conversion Table Symbol definitionsCopyright information Password informationURL Encoding Error responsesUnsafe characters Reserved charactersRelay Functions Command Ascii Telnet URL Encoded Web ResponseInput Contact Closure Port Firmware Version/Part Number/InformationIPL T CR48 Communication IP Setup CommandsRe-map Port Designations File CommandsEvent Control Web Browser SpecificMail Reset Zap/Erase Commands Device Control Accessing and using TelnetCustom Web Pages Telnet PortPower Connections TroubleshootingConfiguration Data ConnectionsSpecifications Specifications Part NumbersIncluded Parts Replacement Part Number AccessoriesAccessories Part Number Part NumbersGlossary IPL T CR48 Glossary Europe, Africa, and the Middle China East USA, Canada, South America Japan Central AmericaAsia Middle East EuropeExtron Middle East
Related manuals
Manual 66 pages 29.57 Kb

IPL T CR48 specifications

The Extron IPL T CR48 is a cutting-edge technology solution designed for modern audiovisual environments. As a compact, high-performance control processor, it is specifically tailored for managing and automating AV systems in various settings, including classrooms, conference rooms, and other collaborative spaces. The IPL T CR48 seamlessly integrates with a wide range of Extron products and third-party devices, making it a versatile choice for any AV installation.

One of the main features of the IPL T CR48 is its powerful control capabilities. It supports up to 48 programmable control ports, which allow users to manage multiple displays, projectors, and other audiovisual equipment effortlessly. This extensive control range ensures that every device in the AV system is easily operable from a single interface, streamlining the user experience.

In addition to its impressive control capabilities, the IPL T CR48 integrates advanced IPLink technology. This unique feature allows for remote control and monitoring of AV systems over an IP network, offering system administrators the flexibility to manage equipment from virtually anywhere. This capability is particularly valuable in large installations, where managing multiple systems simultaneously can be complex and time-consuming.

The IPL T CR48 also boasts a user-friendly interface, thanks to its compatibility with Extron's GlobalViewer Enterprise software. This robust software provides users with a web-based platform for real-time monitoring and management of their AV systems. It enables users to configure, schedule, and control their AV devices, ensuring a smooth operation throughout all events and presentations.

Moreover, the IPL T CR48 is engineered with enhanced security features, including customizable user access levels, ensuring that only authorized personnel can control sensitive equipment. This aspect is crucial for educational and corporate environments, where security and privacy are paramount.

Compact and reliable, the IPL T CR48 excels in both functionality and performance. Its durable design and advanced technologies make it a preferred choice among AV professionals looking to improve the efficiency of their installations. Overall, the Extron IPL T CR48 represents a significant advancement in control processing technology, providing a comprehensive solution for diverse audiovisual applications today.