Configuring the IPL T CR48 using direct PC connection

This type of connection is used initially to connect to and configure the IPL T CR48. The default settings of the unit (IP address, subnet mask, and [optional] administrator name and password) must be changed in order to use the unit on an intranet (LAN) or on the Internet (WAN).

1.Plug one end of a CAT 5 crossover Ethernet cable into the rear panel Ethernet connector on the IPL T CR48. See figure 7 for RJ-45 connector wiring.

2.Plug the other end of the Ethernet cable into the Ethernet port on your PC.

3.Right-click on the Network Neighborhood or My Network Places icon on your Windows (98, 2000, NT, ME, XP) desktop and select Properties from the menu.

4.Select Internet Protocol (TCP/IP) from the list and click on Properties. - or -

If you are using Windows 2000:

a.Right-click Local Area Connection and select Properties from the menu.

b.Select Internet Protocol (TCP/IP) from the list.

c.Click on Properties.

If Internet Protocol (TCP/IP) is not on the list, it must be added (installed). Refer to your Windows user guide or the online Help system for information on how to install the TCP/IP protocol.

5.Write down your current IP address and subnet mask below. If your PC is set to “Obtain an IP address automatically,” make a note of that, instead.

IP Address:

. . .

Subnet Mask:

. . .

6.Click Specify an IP address or Use the following IP address (depending on your operating system) and leave the default gateway blank. Enter the following values:

IP Address: 192.168.254.253

Subnet Mask: 255.255.0.0

7.Save the changes and exit the Network setup. Reboot the PC, if required, for the changes to become effective.

8.Launch your Web browser (Internet Explorer), and type http://192.168.254.254/index.html in the Address field of the browser. The IPL T CR48 default Web page is displayed. See IPL T CR48 Interface Configuration, earlier in this section, for more information on configuring your unit.

9.After configuring your IPL T CR48, repeat steps 3 and 4 to change your TCP/IP settings back to their original configuration.

Firmware upgrades

Firmware upgrades become available as improvements are made to the versatility and functionality of the IPL T CR48. These upgrade are available for download from the Extron Web site. See Upgrading the firmware in the “Communication and Control” section for more information on upgrading the firmware.

IPL T CR48 • Connection and Configuration

14

Image 20
Contents IPL T CR48 Achtung PrecaucionAvertissement VorsichtCopyright Page Contents IPL T CR48 Contents Features IntroductionAbout this Guide About the IPL T CR48Easily configured and controlled Mounting the IPL T CR48 Installation OperationInstallation Overview UL Guidelines for Rack Mounting Rack MountingRear Panel Features and Cabling Furniture or Projector MountingPower Power Connector WiringOperation Ethernet/LANConnections IndentificationFront Panel Indicators Resetting the ControllerIPL T CR48 Reset Mode Summary Mode Activation Result Purpose and NotesUse EventsConnection Configuration Connecting the HardwareEthernet Connection ExtronConfiguring the Hardware PC ConfigurationContact Closure Input and Relay Connections Contact closure input connectionsInitial start up IPL T CR48 Interface ConfigurationConfiguring the IPL T CR48 using the ARP command Executing the ARP Command Select Internet Protocol TCP/IP from the list Configuring the IPL T CR48 using direct PC connectionFirmware upgrades Contact Closure Input Ports Communication ControlPorts Overview Web Server Communication with the InterfaceRelay Ports Accessing and using the Web server Enter Network Password Dialog BoxEstablishing or changing system or port settings Setting and changing your passwordsPasswords Screen SubmitEditing and adding e-mail alerts Email Alerts screenFirmware Upgrade Screen Upgrading the firmwareManaging files File Management ScreenUsing the Command/Response Table Programmer’s Guide for the Telnet and Web BrowserSymbol definitions ASCII-to-HEX Conversion TablePassword information Copyright informationError responses URL EncodingReserved characters Unsafe charactersCommand Ascii Telnet URL Encoded Web Response Relay FunctionsInput Contact Closure Port Firmware Version/Part Number/InformationIP Setup Commands IPL T CR48 CommunicationFile Commands Re-map Port DesignationsEvent Control Web Browser SpecificMail Reset Zap/Erase Commands Accessing and using Telnet Device ControlCustom Web Pages Telnet PortTroubleshooting Power ConnectionsConfiguration Data ConnectionsSpecifications Part Numbers SpecificationsAccessories Included Parts Replacement Part NumberAccessories Part Number Part NumbersGlossary IPL T CR48 Glossary USA, Canada, South America Japan Central America Europe, Africa, and the Middle China EastAsia Middle East EuropeExtron Middle East
Related manuals
Manual 66 pages 29.57 Kb

IPL T CR48 specifications

The Extron IPL T CR48 is a cutting-edge technology solution designed for modern audiovisual environments. As a compact, high-performance control processor, it is specifically tailored for managing and automating AV systems in various settings, including classrooms, conference rooms, and other collaborative spaces. The IPL T CR48 seamlessly integrates with a wide range of Extron products and third-party devices, making it a versatile choice for any AV installation.

One of the main features of the IPL T CR48 is its powerful control capabilities. It supports up to 48 programmable control ports, which allow users to manage multiple displays, projectors, and other audiovisual equipment effortlessly. This extensive control range ensures that every device in the AV system is easily operable from a single interface, streamlining the user experience.

In addition to its impressive control capabilities, the IPL T CR48 integrates advanced IPLink technology. This unique feature allows for remote control and monitoring of AV systems over an IP network, offering system administrators the flexibility to manage equipment from virtually anywhere. This capability is particularly valuable in large installations, where managing multiple systems simultaneously can be complex and time-consuming.

The IPL T CR48 also boasts a user-friendly interface, thanks to its compatibility with Extron's GlobalViewer Enterprise software. This robust software provides users with a web-based platform for real-time monitoring and management of their AV systems. It enables users to configure, schedule, and control their AV devices, ensuring a smooth operation throughout all events and presentations.

Moreover, the IPL T CR48 is engineered with enhanced security features, including customizable user access levels, ensuring that only authorized personnel can control sensitive equipment. This aspect is crucial for educational and corporate environments, where security and privacy are paramount.

Compact and reliable, the IPL T CR48 excels in both functionality and performance. Its durable design and advanced technologies make it a preferred choice among AV professionals looking to improve the efficiency of their installations. Overall, the Extron IPL T CR48 represents a significant advancement in control processing technology, providing a comprehensive solution for diverse audiovisual applications today.