Extron electronic MPS 601 manual Edid Minder, Inputs

Page 42

EDID Minder Page

EDID Minder manages the EDID information between the switcher and one or more input sources. Click the EDID Minder icon on the Global Navigation Bar to open the page.

Figure 29. EDID Minder Page

The EDID Minder page is divided into five panels:

Filter – Select from the drop-down lists in each category to limit the EDIDs shown in the three EDID screens.

Favorites – Drag and drop frequently used EDIDs from the Available EDID panel below.

Connected Outputs – Displays the EDID of the currently connected output.

Available EDID – Displays the current list of EDID files available for assignment.

Inputs – Use this panel to assign an EDID or change a current EDID assignment.

Inputs

The EDID properties currently assigned to each of the six inputs are displayed in the table of inputs on the right side of the EDID Minder page. The audio input format listed in an EDID (unless a custom EDID is used) is determined by the audio input format selected on the audio configuration page (see Audio Config Page on page 39).

MPS 601 • Software Configuration and Control

36

Image 42
Contents Media Presentation Switcher MPSSafety Instructions FCC Class a Notice Software Commands NotificationsContents MPS 601 Switcher Contents Introduction About this User GuideAbout the MPS Extron FeaturesMedia Presentation Switcher IPLMPS 601 Introduction Connections InstallationMounting the Switcher Control Device Connections Contact In/Tally Out SixOutput Power and InputWiring Rgbhv video inputs TwoContact In and Tally Out Connector Wiring Control DevicesContact Closure and Tally Output Application Diagrams Contact Closure Application Diagram with Show Me CablesContact Closure Application Diagram with Individual Switch Lockit Lacing Bracket Installation Lockit Lacing BracketsCabling the MPS 601 Switcher Front Panel Features Input signal LEDs Six green LEDsOperation Audio Features Mode 1 DefaultMedia Presentation Mode Hdmi HdmiReset Mode Auto-input SwitchingFront Panel Lockout Executive Mode Autodetect for AudioAutomatic Mode Input Group Default EdidEdid Minder User assigned Edid Mode Native Refresh Rate Type Video Audio Resolution FormatHdtv Hdmi Remote Control Port RS-232 Remote Communication ControlConnection Options Front Panel Configuration Port To connect the MPS 601 to a host computerInstall the Software Automatically Boot-up messages MPS Switcher-initiated MessagesMPS Switcher Error Responses Host-to-MPS CommunicationsCommand and Response Table Using the Command and Response TableSymbol definitions X3# Command and response table for SIS commands Command Ascii Command Response DescriptionEX!*X3PHAS X!*XHDCP  A X!*X& EDID  Configuration Software Installing the SoftwareStarting the Software Connect to Online DeviceUsing the Software Connections MenuConnect Disconnect Update FirmwareTools Menu ExitMPS 601 Software Configuration and Control Navigating the PCS Application AV Controls PanelConfiguration Pages Input/Output ConfigurationInput Configuration panel Output Configuration panel Edid Minder InputsAvailable Edid panel Filtering Available EdidAssigning Edid Image Settings Signal SamplingAdding Edid to the Edid Library Audio Config Audio ConfigurationDevice Settings Auto Switch panelVisual Indication of Mute Status panel Unit Information To reset the name to the factory defaultHardware Pages Device NameExecutive Mode Executive modeReset Device To reset the deviceReference Information Mounting OptionsUL Rack Mounting Guidelines Rack Mounting Table or Wall MountingThrough-desk Mounting DataViewer Starting the DataViewer programTo access the firmware loader Updating FirmwareDownload the latest firmware file Extron Warranty