Extron electronic MPS 601 manual Device Settings, Auto Switch panel

Page 46

Device Settings Page

The Device Settings page allows configuration of the input autoswitching and the tally out LED indication. Click the Device Settings button on the Global Navigation Bar to open the page.

Figure 32. Device Settings Page

Auto Switch panel

In the absense of active video on the selected input, input auto-switch mode automatically switches inputs based on detected input signals.

1.Select the Enable Auto Switch check box to enable auto-input switch mode.

2.Click the radio button of the desired switch mode from the following:

Priority to the highest active input number — Automatically switches the input to the highest numbered input with active video.

Priority to the lowest active input number — Automatically switches the input to the lowest numbered input with active video.

Visual Indication of Mute Status panel

When an input uses the Extron “Show Me” cable or uses other Contact In / Tally Out connections, the tally indicator can be configured to show the current state of the input.

To configure the indicator select.

Disabled — AV mute is disabled. The selection button provides input switching only with the LED visual indicator always solid. Subsequent selection button presses are ignored.

LED Off When Muted — When selected, a subsequent selection button press button enables AV mute and shuts off the LED visual indicator. Another button press disables AV mute and restores the LED to solid.

LED Blinks When Muted — When selected, a subsequent selection button press button enables AV mute and blinks the LED visual indicator. Another button press disables AV mute and restores the LED to solid.

LED Stays On When Muted — When selected, a subsequent selection button press enables AV mute and the LED visual indicator remains lit solid. Another button press disables AV mute.

MPS 601 • Software Configuration and Control

40

Image 46
Contents Media Presentation Switcher MPSSafety Instructions FCC Class a Notice Software Commands NotificationsContents MPS 601 Switcher Contents About this User Guide IntroductionAbout the MPS Extron FeaturesMedia Presentation Switcher IPLMPS 601 Introduction Connections InstallationMounting the Switcher Control Device Connections Contact In/Tally Out SixOutput Power and InputWiring Rgbhv video inputs TwoContact In and Tally Out Connector Wiring Control DevicesContact Closure and Tally Output Application Diagrams Contact Closure Application Diagram with Show Me CablesContact Closure Application Diagram with Individual Switch Lockit Lacing Bracket Installation Lockit Lacing BracketsCabling the MPS 601 Switcher Input signal LEDs Six green LEDs Front Panel FeaturesOperation Mode 1 Default Audio FeaturesMedia Presentation Mode Hdmi HdmiReset Mode Auto-input SwitchingFront Panel Lockout Executive Mode Autodetect for AudioInput Group Default Edid Automatic ModeEdid Minder User assigned Edid Mode Native Refresh Rate Type Video Audio Resolution FormatHdtv Hdmi Remote Communication Control Remote Control Port RS-232Connection Options Front Panel Configuration Port To connect the MPS 601 to a host computerInstall the Software Automatically Boot-up messages MPS Switcher-initiated MessagesMPS Switcher Error Responses Host-to-MPS CommunicationsUsing the Command and Response Table Command and Response TableSymbol definitions X3# Command and response table for SIS commands Command Ascii Command Response DescriptionEX!*X3PHAS X!*XHDCP  A X!*X& EDID  Configuration Software Installing the SoftwareStarting the Software Connect to Online DeviceConnections Menu Using the SoftwareConnect Disconnect Update FirmwareTools Menu ExitMPS 601 Software Configuration and Control Navigating the PCS Application AV Controls PanelInput/Output Configuration Configuration PagesInput Configuration panel Output Configuration panel Edid Minder Inputs Filtering Available Edid Available Edid panel Assigning Edid Signal Sampling Image SettingsAdding Edid to the Edid Library Audio Config Audio ConfigurationAuto Switch panel Device SettingsVisual Indication of Mute Status panel Unit Information To reset the name to the factory defaultHardware Pages Device NameExecutive Mode Executive modeReset Device To reset the deviceMounting Options Reference InformationUL Rack Mounting Guidelines Rack Mounting Table or Wall MountingThrough-desk Mounting DataViewer Starting the DataViewer programUpdating Firmware To access the firmware loaderDownload the latest firmware file Extron Warranty