Installation and Operation, cont’d
positive or negative H and V sync by rotating either the Adjust horizontal () or Adjust vertical () knob.
If the previous output signal was specified as RGsB or YUV, this submenu will not be displayed because this menu is only active for RGBHV.
Serration pulse removal (Serration)
When set on, serration pulses are removed from the output vertical sync pulse. LCD, DLPs, and plasma displays must have the serration pulses removed from the sync signal in order to display properly. Flagging or bending at the top of the video image is a sign that the serration pulses should be removed. Using either the Adjust horizontal () or Adjust vertical () knob, set the serration pulse removal to either “On” or “Off”. The default is “Off”.
Advanced Configuration
The following flowchart provides an overview of the Advanced Configuration submenus and the options for each setting.
EXTRON QSD204D
MENU
INPUT
CONFIG
MENU
OUTPUT CONFIG
MENU
ADVANCED
CONFIG
NEXT
DETAIL 016
NEXT
FILTER
OFF <ON>
NEXT
BLUEMODE <OFF> ON
NEXT
AUTOSW
<OFF> ON
Either Adjust knob is used to adjust the submenus
Detail (sharpness)
•Ranges from 0 to 63. (default is 16)
Filter
•On (default)
•Off
Display blue and sync only
•On
•Off (default)
Autoswitch mode
•On
•Off (default)
NEXT
ENH MODE <OFF> ON
Enhanced mode (gain control)
•Off (default)
•On
NEXT
Detail control
This submenu allows adjustment of the image detail (sharpness) of the output display. The adjustment ranges from 0 to 63. The default is 16.
Using either the Adjust horizontal () or Adjust vertical () knob, adjust the detail while observing the output display.
Filter mode
The Filter mode, when set “On”, reduces or eliminates aliasing and the resultant “jail bar” effect. For digital displays, set the filter “On” to reduce or eliminate high frequency noise. For CRT output, set the filter “Off”.
Use either the Adjust horizontal () or Adjust vertical () knob to specify this mode as “On” or “Off”. The default is “On”.