Extron electronic DTP T UWP 232/332 D, DTP T HWP 232/332 D manual Edid Values

Page 28

Command Function

SIS Command

Response

Additional Description

 

(Host to Unit)

(Unit to Host)

 

 

 

 

 

EDID Minder

 

 

 

NOTE: See table 1 for the EDID values.

Assign EDID to an input

EAX!*X$EDID}

EdidAX!*X$]

Defaults: 50 (HDMI inputs), 03 (VGA

 

 

 

inputs)

Save the EDID of the connected

ESX$EDID}

EdidSX$]

Save EDID of display connected to the

display to a user location

 

 

output to the user store slot 66, 67, or 68.

View the EDID assignment

EAX!EDID}

X$]

 

View/Read EDID in HEX format

ERX!EDID}

X*]

Read data as text from the EDID assigned

 

 

 

and used on input X!.

View EDID native resolution

ENX!EDID}

X1!]

Read out native resolution and refresh

 

 

 

rate from the EDID assigned to the

 

 

 

specified input in plain text.

 

 

 

Example: 1920x1200 @60Hz

Table 1. EDID Values

X$

Value

X$

Value

X$

Value

X$

Value

VGA – PC values

 

01

800x600 @ 60 Hz

05

1280x800 @ 60 Hz

 

09

1400x1050 @ 60 Hz

13

1680x1050

@ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

1024x768

@ 60 Hz

06

1280x1024 @ 60 Hz

 

10

1440x900 @ 60 Hz

14

1920x1080

@ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03*

1280x720

@ 60 Hz

07

1360x768 @ 60 Hz

 

11

1600x900 @ 60 Hz

15

1920x1200

@ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04

1280x768

@ 60 Hz

08

1366x768 @ 60 Hz

 

12

1600x1200 @ 60 Hz

16

2048x1080

@ 60 Hz

 

 

DVI – PC values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

800x600 @ 60 Hz

21

1280x800 @ 60 Hz

 

25

1400x1050 @ 60 Hz

29

1680x1050

@ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

1024x768

@ 60 Hz

22

1280x1024 @ 60 Hz

 

26

1440x900 @ 60 Hz

30

1920x1080

@ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

1280x720

@ 60 Hz

23

1360x768 @ 60 Hz

 

27

1600x900 @ 60 Hz

31

1920x1200

@ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

1280x768

@ 60 Hz

24

1366x768 @ 60 Hz

 

28

16001200 @ 60 Hz

32

2048x1080

@ 60 Hz

 

 

HDMI – PC values, with 2-channel audio

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

800x600 @ 60 Hz

37

1280x1024 @ 60 Hz

 

41

1440x900 @ 60 Hz

45

1920x1200

@ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

1024x768

@ 60 Hz

38

1360x768 @ 60 Hz

 

42

1600x900 @ 60 Hz

46

2048x1080

@ 60 Hz

 

 

35

1280x768

@ 60 Hz

39

1366x768 @ 60 Hz

 

43

1600x1200 @ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36

1280x800

@ 60 Hz

40

1400x1050 @ 60 Hz

 

44

1680x1050 @ 60 Hz

 

 

 

 

 

HDMI – HDTV values, with 2-channel audio

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

47

480p @ 60 Hz

50

720p @ 60 Hz

 

53

1080p @ 50/25 Hz

56

1080p @ 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48

576p @ 50 Hz

51

1080i @ 50 Hz

 

54

1080p @ 50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

49

720p @ 50 Hz

52

1080i @ 60 Hz

 

55

1080p @ 60/24 Hz

 

 

 

 

 

HDMI – HDTV values, with multi-channel audio

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

720p @ 50 Hz

59

1080i @ 50 Hz

 

61

1080p @ 50/25 Hz

63

1080p @ 60/24 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

58

720p @ 60 Hz

60

1080i @ 60 Hz

 

62

1080p @ 50 Hz

64

1080p @ 60 Hz

 

 

Output and user locations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X$

Source

X$

Source

 

X$

Source

X$

Source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

Output (Auto)

66

User setting 1

 

67

User setting 2

68

User setting 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Default for input 2 (VGA) on UWP models.

Default for input 1 (HDMI) on HWP and UWP models and input 2 on HWP models.

DTP T HWP/UWP 232/332 D Transmitters • Remote Control 22

Image 28
Contents User Guide DTP T HWP 232/332 D DTP T UWP 232/332 DSafety Instructions FCC Class a Notice Registered TrademarksSoftware Commands Commands are written in the fonts shown hereNotifications Following notifications are used in this guideContents Page Introduction About this GuideAbout the DTP T HWP D and DTP T UWP D Extenders Terms Used in this GuideTwisted Pair Cable Advantages Transmission DistanceFeatures UL and Safety Guidelines Installation OperationMounting the Transmitter Site Preparation and Wall Box Installation Installing the Wall Box and Mounting the UnitMud Ring Installation Installing the Mud RingFinal Installation DTP T HWP 232 and 332 D Connections Front PanelDTP T HWP 232 and 332 D Rear Panel Connectors Rear PanelDTP T UWP 232 and 332 D Front Panel Connectors DTP T UWP 232 and 332 D ConnectionsDTP T UWP 232 and 332 D Rear Panel Connectors TP Wires TP Cable Termination and RecommendationsNon-Plenum 1000’ 305 m spool 22-236-03 Plenum 1000’ 305 m spool 22-235-03Power Supply Wiring Power Connector WiringRS-232 and IR Connector Wiring Remote RS-232 and Contact Closure ConnectorIR Control Connector Over DTP RS-232 ConnectorTransmitter LEDs OperationSystem Operation Contact Closure Control Remote ControlThis section includes Error Responses TimeoutSimple Instruction Set Control Host-to-Extender CommunicationsUsing the Command and Response Table X1! =DTP T HWP/UWP 232/332 D Transmitters Remote Control SigX@X@*X@ @X@Command Function SIS Command Response X3@Edid Values EX1& CV VrbX1 Video muteDecora Template Dimensions Reference InformationExtron Warranty