Extron electronic DTP T HWP 232/332 D, DTP T UWP 232/332 D manual EX1& CV VrbX1, Video mute

Page 29

Command Function

SIS Command

Response

Additional Description

 

(Host to Unit)

(Unit to Host)

 

 

 

 

 

Video mute

 

 

 

Enable video mute

1B

Vmt1]

Output no video signal.

Disable video mute

0B

Vmt0]

Output selected video input.

View video mute status

B

X@]

Mute status = X@ (0 = off, 1 = on)

Video breakaway

 

 

 

Select program video input only

X!%

InX!Vid]

X! = input number 0 - 2 only

View currently selected video input

%

X!]

 

 

 

 

 

Analog audio mute

 

 

 

Mute or unmute analog audio

X@Z

AmtX@]

X@ = 0 (off, default), 1 (on)

Read analog audio mute

Z

X@]

Analog audio mute status = X@.

 

 

 

 

Analog audio breakaway

 

 

 

Select program audio input only

X!$

InX!Aud]

X! = 0 - 2 only (analog audio input)

View currently selected audio input

$

X!]

 

 

 

 

 

Video output color bit depth

 

 

 

Set video color bit depth mode

EVX(BITD}

BitdVX(]

0 = auto based on sink (default)

 

 

 

1 = force 8-bit

View video color bit depth mode

EVBITD}

X(]

 

 

 

 

 

Device name

 

 

 

Set the device name

EX&CN}

IpnX&]

Change the device name to X&.

Set device name to factory default

ECN}

IpnDTP-T-xxx-xxx]

Set device name to default.

 

 

 

(Example: DTP-T-HWP-232)

View device name

ECN}

X&]

 

 

 

 

 

Reset

 

 

 

Reset to factory setting

EZXXX}

Zpx]

Reset to factory defaults.

 

 

 

 

Upload firmware

 

 

 

Upload

EUpload}

...go

Upl] displays after upload is

 

 

Upl]

completed.

 

 

 

 

Information requests

 

 

 

Information request

I

InX!VidInX!AudAuswX#VmtX@AmtX@]

Request part number

N

60-nnnn-nn]

See the Extron website,

 

 

 

www.extron.com, for part numbers.

Query firmware version

Q

x.xx]

 

Query firmware version w/build

*Q

x.xx.xxxx]

 

Verbose mode

NOTE: If tagged responses are enabled (modes 2 and 3), all “view” commands return the prefix and the value, just as the “set” commands do. For example, the view autoswitch mode (EAUSW}) command returns “AuswX#]” in verbose mode.

Set verbose mode

EX1&CV}

VrbX1&]

 

 

Read verbose mode

ECV}

X1&]

0 = clear/none

 

 

 

1

= verbose mode (default)

 

 

 

2

= tagged responses for queries

 

 

 

3

= verbose mode and tagged for queries

DTP T HWP/UWP 232/332 D Transmitters • Remote Control 23

Image 29
Contents DTP T HWP 232/332 D DTP T UWP 232/332 D User GuideSafety Instructions Registered Trademarks FCC Class a NoticeCommands are written in the fonts shown here Software CommandsNotifications Following notifications are used in this guideContents Page About this Guide IntroductionAbout the DTP T HWP D and DTP T UWP D Extenders Terms Used in this GuideTransmission Distance Twisted Pair Cable AdvantagesFeatures Mounting the Transmitter Installation OperationUL and Safety Guidelines Installing the Wall Box and Mounting the Unit Site Preparation and Wall Box InstallationInstalling the Mud Ring Mud Ring InstallationFinal Installation Front Panel DTP T HWP 232 and 332 D ConnectionsRear Panel DTP T HWP 232 and 332 D Rear Panel ConnectorsDTP T UWP 232 and 332 D Connections DTP T UWP 232 and 332 D Front Panel ConnectorsDTP T UWP 232 and 332 D Rear Panel Connectors TP Cable Termination and Recommendations TP WiresNon-Plenum 1000’ 305 m spool 22-236-03 Plenum 1000’ 305 m spool 22-235-03Power Connector Wiring Power Supply WiringRemote RS-232 and Contact Closure Connector RS-232 and IR Connector WiringIR Control Connector Over DTP RS-232 ConnectorSystem Operation OperationTransmitter LEDs This section includes Remote ControlContact Closure Control Timeout Error ResponsesSimple Instruction Set Control Host-to-Extender CommunicationsX1! = Using the Command and Response TableDTP T HWP/UWP 232/332 D Transmitters Remote Control @X@ SigX@X@*X@X3@ Command Function SIS Command ResponseEdid Values Video mute EX1& CV VrbX1Reference Information Decora Template DimensionsExtron Warranty