Extron electronic DTP T UWP 232/332 D manual TP Cable Termination and Recommendations, TP Wires

Page 18

TP Cable Termination and Recommendations

Figure 9 details the recommended termination of both ends of TP cables with RJ-45 connectors in accordance with the TIA/EIA-T568Bwiring standard.

 

 

 

Pins:

 

 

 

 

TIA/EIA

 

12345678

 

 

 

 

 

 

 

 

 

T568-B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin

Wire color

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

White-orange

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Orange

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

White-green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

White-blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

White-brown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TP Wires

8

Brown

 

 

 

 

 

 

 

 

 

Figure 9. TP Cable Termination

NOTE: Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable to link the transmitter and receiver. The DTP T HWP D and DTP T UWP D family of transmitters do not work properly with these cables.

Supported cables

The DTP T HWP D and DTP T UWP D family of transmitters are compatible with shielded twisted pair cables (F/UTP, SF/UTP, and S/FTP).

Cable recommendations

Extron recommends using the following practices to reduce transmission errors and achieve full transmission distances up to 230 feet (70 m) on the 232 models or 330 feet (100 m) on the 332 models.

Use the following Extron XTP DTP 24 SF/UTP cables and DTP 24 connectors for the best performance:

XTP DTP 24/1000

Non-Plenum 1000’ (305 m) spool

22-236-03

XTP DTP 24P/1000

Plenum 1000’ (305 m) spool

22-235-03

XTP DTP 24 Plug

Package of 10

101-005-02

If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid conductor, STP cable with a minimum bandwidth of 400 MHz.

Terminate cables with shielded connectors to the TIA/EIA-T568B standard.

Use no more than two pass-through points, which may include patch points, punch down connectors, couplers, and power injectors. If these pass-through points are required, use shielded couplers and punch down connectors.

NOTE: When using STP cable in bundles or conduits, consider the following:

Do not exceed 40% fill capacity in conduits.

Do not comb the cable for the first 20

meters, where cables are straightened,

aligned, and secured in tight bundles.

 

Loosely place cables and limit the use of tie wraps or Velcro®.

Separate twisted pair cables from AC power cables.

DTP T HWP/UWP 232/332 D Transmitters • Installation and Operation 12

Image 18
Contents User Guide DTP T HWP 232/332 D DTP T UWP 232/332 DSafety Instructions FCC Class a Notice Registered TrademarksNotifications Software CommandsCommands are written in the fonts shown here Following notifications are used in this guideContents Page About the DTP T HWP D and DTP T UWP D Extenders IntroductionAbout this Guide Terms Used in this GuideTwisted Pair Cable Advantages Transmission DistanceFeatures Installation Operation UL and Safety GuidelinesMounting the Transmitter Site Preparation and Wall Box Installation Installing the Wall Box and Mounting the UnitMud Ring Installation Installing the Mud RingFinal Installation DTP T HWP 232 and 332 D Connections Front PanelDTP T HWP 232 and 332 D Rear Panel Connectors Rear PanelDTP T UWP 232 and 332 D Front Panel Connectors DTP T UWP 232 and 332 D ConnectionsDTP T UWP 232 and 332 D Rear Panel Connectors Non-Plenum 1000’ 305 m spool 22-236-03 TP WiresTP Cable Termination and Recommendations Plenum 1000’ 305 m spool 22-235-03Power Supply Wiring Power Connector WiringIR Control Connector RS-232 and IR Connector WiringRemote RS-232 and Contact Closure Connector Over DTP RS-232 ConnectorOperation Transmitter LEDsSystem Operation Remote Control Contact Closure ControlThis section includes Simple Instruction Set Control Error ResponsesTimeout Host-to-Extender CommunicationsUsing the Command and Response Table X1! =DTP T HWP/UWP 232/332 D Transmitters Remote Control SigX@X@*X@ @X@Command Function SIS Command Response X3@Edid Values EX1& CV VrbX1 Video muteDecora Template Dimensions Reference InformationExtron Warranty