Extron electronic DTP T UWP 232/332 D manual Using the Command and Response Table, X1! =

Page 24

Using the Command and Response Table

The command and response table begins on page 20. Symbols are used throughout the table to represent variables in the command and response fields. Command and response examples are shown throughout the table. The ASCII to HEX conversion table below is for use with the command and response table.

NOTE: Upper and lowercase text can be used interchangeably unless otherwise stated.

ASCII to Hex Conversion Table

Space

Symbol definitions

DTP T HWP 232/332 D and DTP UWP 232/332 D models

] = Carriage return/line feed

}= Carriage return (no line feed)

= Pipe (can be used interchangeably with the } character)

= Space

E = Escape key

W = Can be used interchangeably with the E character

X!

=

Input number

0 through 2 (0 = deselect input [break tie]. This results in the output being disabled.)

 

 

 

1

= HDMI, 2 = VGA (UWP models)

X@

=

Status

0

= off, disabled, or not detected

 

 

 

1

= on, enabled, or detected

X#

=

Auto switch mode

0

= disabled (default)

 

 

 

1

= enabled (highest active input has priority)

X$

= EDID

See table 1 on page 22.

X%

=

Input HDCP status

0

= No source is detected

 

 

 

1

= Source is detected with HDCP

 

 

 

2

= Source detected without HDCP

X^

=

Output HDCP status

0

= No sink is detected

 

 

 

1

= Sink is detected with HDCP support

 

 

 

2

= Sink is detected without HDCP support

X&

=

Transmitter name

A text string of up to 24 alphanumeric characters and minus sign/hyphen (-).

 

 

 

No blank or space characters are permitted as part of a name. The first letter must a

 

 

 

letter, and the last character must not be a minus sign/hyphen (default is

 

 

 

DTP-T-HWP/UWP-232/332).

X*

=

Raw EDID data

128 or 256 bytes of hexadecimal data

X(

=

Video color bit depth mode

0

= Auto (default, based on sink EDID)

 

 

 

1

= force 8-bit

X1)

=

Analog input video format (UWP models only)

0

= Auto detect (default)

 

 

 

1

= RGB/VGA

 

 

 

2

= YUV/component video

X1! =

Current EDID native resolutions and refresh rate in plain text

DTP T HWP/UWP 232/332 D Transmitters • Remote Control 18

Image 24
Contents User Guide DTP T HWP 232/332 D DTP T UWP 232/332 DSafety Instructions FCC Class a Notice Registered TrademarksSoftware Commands Commands are written in the fonts shown hereNotifications Following notifications are used in this guideContents Page Introduction About this GuideAbout the DTP T HWP D and DTP T UWP D Extenders Terms Used in this GuideTwisted Pair Cable Advantages Transmission DistanceFeatures Installation Operation UL and Safety GuidelinesMounting the Transmitter Site Preparation and Wall Box Installation Installing the Wall Box and Mounting the UnitMud Ring Installation Installing the Mud RingFinal Installation DTP T HWP 232 and 332 D Connections Front PanelDTP T HWP 232 and 332 D Rear Panel Connectors Rear PanelDTP T UWP 232 and 332 D Front Panel Connectors DTP T UWP 232 and 332 D ConnectionsDTP T UWP 232 and 332 D Rear Panel Connectors TP Wires TP Cable Termination and RecommendationsNon-Plenum 1000’ 305 m spool 22-236-03 Plenum 1000’ 305 m spool 22-235-03Power Supply Wiring Power Connector WiringRS-232 and IR Connector Wiring Remote RS-232 and Contact Closure ConnectorIR Control Connector Over DTP RS-232 ConnectorOperation Transmitter LEDsSystem Operation Remote Control Contact Closure ControlThis section includes Error Responses TimeoutSimple Instruction Set Control Host-to-Extender CommunicationsUsing the Command and Response Table X1! =DTP T HWP/UWP 232/332 D Transmitters Remote Control SigX@X@*X@ @X@Command Function SIS Command Response X3@Edid Values EX1& CV VrbX1 Video muteDecora Template Dimensions Reference InformationExtron Warranty