Extron electronic DTP T HWP 232/332 D manual Command Function SIS Command Response, X3@

Page 27

Command Function

SIS Command

Response

Additional Description

 

(Host to Unit)

(Unit to Host)

 

Picture adjustment (RGB input only, UWP models only )

Set pixel phase value

E2*X3)PHAS}

Phas2*X3)]

 

Increment pixel phase value

E2+PHAS}

Phas2*X3)]

X3) = Pixel phase (0-63, default is 32)

Decrement pixel phase value

E2-PHAS}

Phas2*X3)]

 

View pixel phase value

E2PHAS}

X3)]

 

 

 

 

 

Set total pixels value

E2*X3!TPIX}

Tpix2*X3!]

 

Increment total pixels value

E2+TPIX}

Tpix2*X3!]

X3! = ±255 of default value (depends

 

 

 

on input rate)

Decrement total pixels value

E2-TPIX}

Tpix2*X3!]

 

View total pixels value

E2TPIX}

X3!]

 

 

 

 

 

Set horizontal start value

E2*X3@HSRT}

Hsrt2*X3@]

 

Increment horizontal start value

E2+HSRT}

Hsrt2*X3@]

X3@ = 0-255 (default is 128)

Decrement horizontal start value

E2-HSRT}

Hsrt2*X3@]

 

View horizontal start value

E2HSRT}

X3@]

 

 

 

 

 

Set vertical start value

E2*X3@VSRT}

Vsrt2*X3@]

 

Increment vertical start value

E2+VSRT}

Vsrt2*X3@]

X3@ = 0-255 (default is 128)

Decrement vertical start value

E2-VSRT}

Vsrt2*X3@]

 

View vertical start value

E2VSRT}

X3@]

 

DTP T HWP/UWP 232/332 D Transmitters • Remote Control 21

Image 27
Contents DTP T HWP 232/332 D DTP T UWP 232/332 D User GuideSafety Instructions Registered Trademarks FCC Class a NoticeFollowing notifications are used in this guide Software CommandsCommands are written in the fonts shown here NotificationsContents Page Terms Used in this Guide IntroductionAbout this Guide About the DTP T HWP D and DTP T UWP D ExtendersTransmission Distance Twisted Pair Cable AdvantagesFeatures Installation Operation UL and Safety GuidelinesMounting the Transmitter Installing the Wall Box and Mounting the Unit Site Preparation and Wall Box InstallationInstalling the Mud Ring Mud Ring InstallationFinal Installation Front Panel DTP T HWP 232 and 332 D ConnectionsRear Panel DTP T HWP 232 and 332 D Rear Panel ConnectorsDTP T UWP 232 and 332 D Connections DTP T UWP 232 and 332 D Front Panel ConnectorsDTP T UWP 232 and 332 D Rear Panel Connectors Plenum 1000’ 305 m spool 22-235-03 TP WiresTP Cable Termination and Recommendations Non-Plenum 1000’ 305 m spool 22-236-03Power Connector Wiring Power Supply WiringOver DTP RS-232 Connector RS-232 and IR Connector WiringRemote RS-232 and Contact Closure Connector IR Control ConnectorOperation Transmitter LEDsSystem Operation Remote Control Contact Closure ControlThis section includes Host-to-Extender Communications Error ResponsesTimeout Simple Instruction Set ControlX1! = Using the Command and Response TableDTP T HWP/UWP 232/332 D Transmitters Remote Control @X@ SigX@X@*X@X3@ Command Function SIS Command ResponseEdid Values Video mute EX1& CV VrbX1Reference Information Decora Template DimensionsExtron Warranty