ATTO Technology S-Class manual To set up the Jbod configuration

Page 62

6.1 JBOD

The Diamond Storage Array is set up in a JBOD (Just a Bunch of Disks) configuration as default. JBOD configuration allows for many individual disk drives to be available for normal storage operations.

CAUTION

Selecting JBOD configuration causes all previous drive data on the Diamond Storage Array to be erased. Make sure all of your information is backed up before setting up the Diamond Storage Array in a JBOD configuration.

A JBOD configuration allows you to access each of the possible 24 disk drives in the Diamond Storage Array independently. In this configuration, any action you can do to a normal disk drive can be performed on any disk in the JBOD.

To set up the JBOD configuration

1Connect to Diamond Storage Array services via the RS-232 port or the optional Ethernet management services card (refer to Accessing the Array on page 17). You should now be in Command Line Interface.

1Continue with the CLI or access the RAID page of the ExpressNAV interface (refer to ATTO ExpressNAV: Browser-based Interface on page 25).

Note

Because the ExpressNAV pages take you through this process easily, the following instructions are based on the CLI commands. Use these instructions as a guide in ExpressNAV.

2Type set QuickRAID0 0. The command will configure the Diamond Storage Array in the JBOD configuration.

3Information will display on the screen while the Diamond Storage Array updates NVRAM. The Ready* prompt displays.

4Type SaveConfiguration to save the JBOD configuration.

5Type FirmwareRestart to reboot the Diamond Storage Array.

6Reboot the host computer.

The Diamond Storage Array is now configured as a set of individual disk drives.

7To verify the configuration, type DriveInfo. If any sleds are missing, the sled slots will be reported as offline.

51

ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual

Image 62
Contents Diamond Storage Array Class Page Page Contents In-band CLI Over the Fibre Channel Serial Port Configuration Commands Configuring Drives RAID Interleave Parameters Appendix D Specifications Vii Appendix E Warranty ViiiPreface Atto Technology, IncPage Diamond Storage Array features Diamond Storage Array Product OverviewFibre Channel model Scsi modelAdxt Powers ATA to New Levels Diamond Storage Array Technical OverviewATA Interface Engine AIE The interface to each Set up the Ethernet connection Installation InstructionsPhysical setup Connect to EthernetSet up RAID configuration Rack mount ComponentsFloor model Components Rack mount cabinets with stationary shelf or tray Physical Set UpSpaced rail pairs in some rackmount cabinets Sliding shelf or tray type systems should neverGeneral instructions Manual configuration Connecting a Fibre Channel ArrayAutoconfiguration Fibre Channel connections Bus speed, MB/sec Bus width Max. bus lengths Max. device Connecting a Scsi ArrayTo connect a Scsi array BitsScsi connections Logical numbering Determining Drive and Sled DesignationsPhysical numbering Numbering conventionsRAID Level 10 QuickRAID10 The QuickRAID10 ExamplesUnique serial number for each LUN RAID Level 5 QuickRAID5 with a fullyAtto ExpressNAV Accessing the ArrayCommand Line Interface RS-232 portSnmp Initiator Host Diamond Array In-band CLI Over the Fibre ChannelDetails Invalidparameterincdb will be returned Initiator/Host Diamond Storage ArraySerial Port Access Serial port access To use Telnet Ethernet Access Telnet and Snmp ProtocolsTo connect to the Ethernet port To use SnmpType SaveConfiguration restart to reboot the array Traps are generated for the following situationsOpening an ExpressNAV session Atto ExpressNAV Browser-based InterfaceBrowser compatibility Navigating ExpressNAVInformation Sidebar ExpressNAV Pages Logical Units ConfigurationClear Data RebuildCommand Line Interface Use and Guidance Command Line Interface actions and responsesPage Summary of CLI Commands Command Defaults ExampleCommand Defaults Example General Use Commands General CLI commands Ethernet Commands TelnetUsername TelnetPasswordTelnetTimeout Fibre Channel Configuration Commands FcPortName FcPortInfoFcPortList FcWWNameSerialPortHandshake Serial Port Configuration CommandsSerialPortBaudRate SerialPortEchoSerial port CLI commands Diagnostic Commands SMARTData SledFaultLEDTemperature VirtualDriveInfoMaxEnclTempAlrm Maintenance CommandsFcScsiBusyStatus MinEnclTempAlrmMaintenance CLI commands Drive Configuration Commands LUNState DriveWipeIdeTransferRate QuickRAID0RAID5ClearDataStatus RestoreModePagesRAID5ClearData RAIDInterleaveExamples, refer to Information Commands Results on RAID Level Configuring DrivesJbod Just a Bunch of Disks Enhancing performance InterleaveHot Spare sleds To set up the Jbod configuration JbodJbod RAID Level Sled-based versus disk-basedTo remove RAID Level 0 groups LUNs virtual drive numbersPage Page Type SaveConfiguration Storage Management To set up RAID Level 1 groupsType SaveConfiguration To remove RAID groupsTo set up RAID Level 1 with Hot Spare sleds Type set QuickRAID 1To set up one RAID Level 5 group with one Hot Spare sled Configuring a fully-populated arrayTo set up RAID Level 5 groups Type set QuickRAID5 2 Type SaveConfiguration Restart Type set QuickRAID5 1 Type SaveConfiguration RestartTo set up two RAID Level 5 groups with two Hot Spare sleds LUN Type set QuickRAID5 ALL Type SaveConfiguration Restart Removing RAID groupsTo set up RAID Level 10 groups Type set QuickRAID10 0 1 2To set up RAID Level 10 with Hot Spare sleds Type set QuickRAID10 1 Type SaveConfiguration RestartRebuilding RAID Configurations Set AutoRebuild disabled saveconfiguration restart To synchronize mirrored drives manuallyRAID Interleave Parameters To change the RAID Interleave parameterRAID interleave Hardware Maintenance Maintenance Hot Swap Operating Instructions Disk drivesBlower assemblies Power suppliesTo replace a blower assembly Type set QuickRAID1 Type SaveConfiguration Restart Optional Hot Spare SledTo set up two RAID Level 5 groups with Hot Spare sleds Virtual Drive Hot Spare sledsProcedure Copying DrivesCopy drives Updating firmware using the RS-232 serial port Updating FirmwareCd c\diamond\flash Type put ....imaSystem Monitoring and Reporting Power supply monitoring System fault LED and error codesNumber of blinks Command Line Interface messages TroubleshootingWindows 2000 special instructions Error messages Specific situations and suggestions If LUNs do not display on the host Type FirmwareRestartFactory Default Resetting DefaultsDefault To return to Default settingsCommand Default Reset if default Reset during Chosen Feature Fibre ChannelAppendix B Information Commands Results DriveInfo sled ID drive IDInfo all V80DTESCLUNInfo LUN LunInfoVirtualDriveInfo active planned Virtual Drive ID VirtualDriveInfoSafety compliances EMC specifications Radio and television interferenceEnvironmental and physical Rack mount dimensionsFloor mount dimensions Manufacturer limited warranty Contact Atto Technology, Inc

S-Class specifications

ATTO Technology S-Class is a comprehensive solution designed to optimize storage and networking performance for digital content creation and enterprise environments. This product line specializes in high-performance connectivity, facilitating seamless data transfer and management.

One of the key features of the S-Class is its advanced RAID (Redundant Array of Independent Disks) capabilities. This incorporates various levels of RAID configurations, enabling users to choose the right balance between performance and redundancy. The technology ensures data integrity while maximizing throughput, a crucial aspect for workflows dealing with large files such as video editing and graphic design.

Another standout characteristic of the S-Class is its support for high-speed interfaces, including Thunderbolt and Fibre Channel. With the ability to leverage these high-bandwidth connections, users can achieve exceptional data transfer rates that significantly reduce the time required for file uploads and transfers. This is particularly important in environments demanding real-time data access, such as broadcasting and production studios.

The S-Class also incorporates intelligent storage management features. The ATTO ConfigTool offers a user-friendly interface for monitoring and configuring storage settings, allowing for real-time adjustments and performance tuning. This ensures that users can effectively manage their storage resources, balancing capacity and performance according to their specific needs.

Furthermore, the technology employs a robust set of data protection mechanisms, including snapshot and backup capabilities. This ensures that critical data is safeguarded against potential loss, enhancing operational reliability. The integration of these features supports comprehensive workflow solutions, benefiting industries that require continuous access to high-volume data.

Lastly, the S-Class is built to integrate seamlessly with popular operating systems and platforms, providing versatility and ease of deployment. Whether used in a small studio or a large enterprise environment, ATTO Technology's S-Class stands out as a solution that combines speed, reliability, and manageable performance, making it a top choice for professionals who demand the best in their storage and network infrastructure.

In summary, ATTO Technology S-Class is not just a storage solution; it's a gateway to unlocking peak performance in data management, tailored for the challenges of today’s data-driven landscape.