When you press the LED test button:
1The Controller Module initiates a test to all modules in the hub. All LEDs should respond by lighting continuously for approximately
5 seconds.
2During this time, the
See Appendix B for instructions about contacting 3Com Technical Support for your product.
Reading the Base Module LEDs
Table
Table
Module Status | LED State |
|
|
|
|
| MOD | PACKET |
| STAT | CHANNEL |
|
|
|
Prior to | Off | Off |
|
|
|
Diagnostics upon | Yellow | Off |
|
|
|
Failed diagnostics | Yellow | Green |
|
|
|
Passed diagnostics; ready to exchange data | Green | Green |
|
|
|
Receiving ATM cells and forwarding them to | Green | Yellow |
the packetchannel backplane |
|
|
|
|
|
Module problem indications during normal | Steady yellow or | Off |
operation* | Off |
|
* Refer to Determining Corrective Action.