Tripp Lite SU60KX manual Basic Operation, Technical Specifications, KX Models

Page 3

1 Basic Operation

1.1 Technical Specifications

KX Models:

 

 

 

Model

SU20KX

SU40KX

 

SU60KX

SU80KX

 

 

 

(Capacity)

(20kVA/16kW)

(40kVA/32kW)

 

(60kVA/48kW)

(80kVA/64kW)

Input

Input Voltage

 

 

220/380V, 230/400V or 240/415V AC, 3O, 4-wire + ground, wye

 

 

 

 

 

 

 

 

 

 

Voltage Regulation

 

 

-25% ~ +20%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Harmonic Distortion

 

 

< 5% (Full Load)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PFC (Full Load)

 

 

> 0.99

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

 

50 / 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency Tolerance

 

 

45 ~ 65 Hz

 

 

 

 

 

 

 

 

 

 

 

 

Output

Output Voltage

 

 

220/380V, 230/400V or 240/415V AC, 3O, 4-wire + ground, wye

 

 

 

 

 

 

 

 

 

 

Output Frequency

 

 

50 / 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Harmonic (Linear Load)

3%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage Regulation

Static

±1%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dynamic

±7% (10% ~ 90% Linear Load)

 

 

 

 

 

 

 

 

 

 

 

 

Frequency Regulation

Interior Oscillator

±0.05 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Synchronized

±5%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overload

 

 

125% : 10 minutes; 150% : 1 minute

 

 

 

 

 

 

 

 

 

 

 

Audible Warning

Battery Backup

 

 

Intermittent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UPS Abnormal

 

 

Continuous

 

 

 

 

 

 

 

 

 

 

 

 

Display

LED

 

 

UPS Status: Normal • Bypass • Backup • Fault

 

 

 

 

 

 

 

 

 

 

LCD

 

 

Input/Output • Bypass • Inverter • Frequency • Loading • Battery Voltage

 

 

 

 

UPS abnormal messages with intelligent self-diagnosis.

 

 

 

 

 

 

 

 

 

 

Interface

Standard

 

 

RS-232, Dry Contact

 

 

 

 

 

 

 

 

 

 

 

 

Optional

 

 

SNMPWEBCARD

 

 

 

 

 

 

 

 

 

 

 

 

Others

Parallel Redundancy

 

 

Yes (1+1 for 2 UPS systems of the same type and capacity only.)

 

 

 

 

 

 

 

 

 

 

EPO

 

 

Standard (Local and Remote)

 

 

 

 

 

 

 

 

 

 

 

 

SRAM Event Log

 

 

500 Records

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Configuration

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Standby Installation

 

 

Optional

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery Temperature Compensation

Optional

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery Cold-Start

 

 

Standard

 

 

 

 

 

 

 

 

 

 

 

 

 

Overall

Efficiency

Normal

94%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ECO

97%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transfer Time

 

 

0 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

 

32° F ~ 104° F (0° C ~ 40° C)

 

 

 

 

 

 

 

 

 

 

 

 

Humidity (non-condensing)

90%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Noise (1 m)

 

 

65 dBA

68 dBA

 

70 dBA

70 dBA

 

 

 

 

 

 

 

 

 

 

Dimensions (Power Module)

Width

520 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

850 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

1165 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight (Power Module)

 

 

267 kg*

412 kg*

 

210 kg

244 kg

 

 

 

 

 

 

 

 

 

3

Image 3
Contents Th Street, Chicago, IL 60609 USA Table of Contents Basic Operation Technical SpecificationsKX Models SU40K SU60K SU60KTV SU80KTV KTV ModelsModel Capacity SU80K 80kVA/64kW SU80K ModelFeatures Advanced FeaturesControl Panel Features 3a SU40KX front Front and Rear Panel Features3b SU40KX rear 3c SU40K front 3d SU40K rear 3e SU80K front 3f SU80K rear Internal Battery Layout Operating PrinciplesSystem Layout Power Module Layout 3a Power Module Block DiagramOpening and Closing the Unit Manual Bypass Mode Single UPS Online Normal Mode Single UPSBattery Backup Mode Single UPS Auto Bypass Mode Single UPSOnline Mode Parallel UPS Battery Backup Mode Parallel UPSAuto Bypass Mode Parallel UPS Hot Standby Mode Parallel UPS Manual Bypass Mode Parallel UPSStandard Start-Up Procedure Single UPS Control Panel and Breaker DiagramsNormal LED Battery LED Bypass LED Fault LED Preliminary Checklist Single UPSBattery Start-Up Procedure Single UPS Shutdown Procedure Single UPS Manual Bypass Procedure Single UPSStart-Up Procedure Parallel UPS Preliminary Checklist Parallel UPSShutdown Procedure Parallel UPS Manual Bypass Procedure Parallel UPS Switching from Manual Bypass to Normal Mode Parallel UPS SU80KX SU60KX SU40KX SU80KTV SU20KX Printed Circuit Boards PCBPCB Location System F3 FB M LA, LB, LC, LD Models LA, LB, LC LA, LB, LC, LD F1BYP F1MAIN F2BYP F2MAIN LCD PCB Board Name Description PCB Location Power ModuleKX Models Block and Wiring Diagrams1a SU20KX Block Diagram 1c SU40KX Block DiagramDC Auxiliary Power Circuit Auxiliary Power Failure DetectionTheory of Operation W18 Output Current DetectionLocated at NH-SYS-M board System MCU and Control Circuit Input Voltage DetectionLocated at NH-SYS-M board System MCU and Control Circuit Output Voltage DetectionUP10B Battery Voltage DetectionScrst R Bypass SCR Short-Circuit DetectionTSA1 Bypass SCR DriverWatchdog for System MCU To LCD LCD Panel Control CircuitLocated on NH-SYS-M board System MCU and Control Circuit Fan Control CircuitCommunication Circuit for RS232 Bypass SCR Temperature DetectionCommunication Circuit for Slots RS232 PortOutput DRY Contact Communication Circuit for Output Dry ContactInput DRY Contact Communication Circuit for Input Dry Contact and RepoEXTBTEMP1 External Battery Cabinet Temperature DetectionDetection Circuit for Output Breaker Detection Circuit for Manual Bypass SwitchCentralok Control Circuit for Power ModuleTo PM1 to PM2 CM93 Control Circuit for External Parallel CM106 CM109Theory of Operation 02a Front Control Panel Emergency Power Off EPOCommunication 01 RS232 PortRemote Emergency Power Off Repo 02b02c Polling and Updating Eeprom Setting Eeprom on the NH-M BoardCalibrating Eeprom Gain Setting Output Dry Contact Status Upgrading Firmware for the System Board Output Manual Bypass Main Input N C S T G R G I N G R a D E Communication Upgrading Firmware for the Power Module PM1 U P S T G R G I N Link the UPS to a PC via the RS232 port Communication Communication Communication T I N G L O W E D Downloading the Event Log Internal Battery Battery StringsFront View of SU20KX and SU40KX Installing and Removing Internal Batteries Terminals Injury and property damage Battery compartment. Warning Observe proper polarity byConnecting negative to negative black to black and positive Damage the UPS system and create a serious risk of personal2a BP480V26B 2b BP480V40C Battery CabinetInternal Battery 2e Connection between UPS and Battery Cabinet 2f Wiring between UPS and Battery Cabinet2d W1 and W2 Cables Troubleshooting Alarm Messages1a Warning Message List Condition 1b Power Module Warning Message ListMain VOLT/FREQ NOK Troubleshooting Flow ChartsMain Sequence NOK Bypass VOLT/FREQ NOK Bypass Sequence NOK Bypass Static Switch Over TemperatureBypass Static Switch Overload Bypass Static Switch FaultUPS Internal Comm Abnormal Same fault message? Replace the power moduleBattery Test Fail Battery Over Charge10a 11a 11b Battery BAD12a 12b 12c Bypass FAN Failure13a 13b Transformer Overheat14a 14b PS Output Volt NOK15a 15b PS EXT Parallel Comm Abnormal16a 16b Parallel Failure17a Redundancy LossFailure Power Module Identify Power Module115 116 Power Module Replacement AC Input DC Input Output 119 120 Suggested tools and supplies Preventive MaintenanceSafety Overview UPS ProcedureInternal Battery Procedure Multi-Meter Oscilloscope Appendix a Service Equipment and ToolsRecommended Equipment and Tools Software ToolsFig B.a Appendix B Torque TableKX Models Table B.1Models Table B.2Table B.3 Fig B.b Fig B.c KTV Models Table B.4Fig B.d Appendix C PCB and Test Point NH-SYS-P BoardNH-SYS-R Board